Records from 2016 to 2025. Most recent: inspection, 13 February 2025.
Inspection history · 17
13 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8079146
24 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8008863
11 March 2024
Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7876176
7 March 2024
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7875202
6 February 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7632769
20 March 2022
Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7415669
9 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7408343
29 April 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7185919
4 February 2021
Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7135830
5 October 2020
Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7071602
28 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6945188
31 March 2020
Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6933849
24 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6724000
8 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6398250
3 April 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6384350
15 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6146988
8 March 2016
COI Inspection · In-Service Inspection · Drydock Exam · Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5831107
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 13 February 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Placard was worn and illegible. Replace. 46 CFR 184.506
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 3 March 2025
Resolution: Operator installed new placard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 February 2025
Resolved
Vessel must carry three hand red flare and three hand orange smoke distress signals. Three of one may be substituted for the other. Four of the six hand red flare distress signals were found to be expired. Expired flares were replaced during inspection. 46 CFR 180.68 (b) & (c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 February 2025
Resolution: Operator replaced expired flares during inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 March 2022
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including inspection of each portable fire extinguisher to check for excessive corrosion and general condition. Portable fire extinguisher adjacent to operating station displays an inadequate pressure reading (half filled). 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator received a new extinguisher. Verified that the extinguisher's pressure was adequate.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2017
Resolved
Properly secure waterlight lanyard on ring buoy. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Properly secured waterlight lanyard on ring buoy.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2017
Resolved
Properly secure wiring for port speakers no longer in service.46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Properly secured wiring for port speakers no longer in service
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 15 May 2017
Resolved
Provide bonding on fuel fill. 46 CFR 182.445
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Provided bonding on fuel fill.