MAURY USCG vessel records Sign in
← All vessels

EUGENIUSZ KWIATKOWSKI

EUGENIUSZ KWIATKOWSKI is a 1975 freight ship. The Coast Guard has recorded 15 inspections since 1992, most recently in April 1997, along with 16 deficiencies and 1 operational control.

Records from 1992 to 1997. Most recent: inspection, 28 April 1997.

Built
1975
Last inspected
28 April 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7384132 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
376741
Flag
POLAND
—
Maury page id
psix-376741

Inspections, by type

…with no type recorded14
Years with a record 6 calendar years (1992–1997)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10128 - Regulatory (Subpart C or D), Gross Ton
5604 - Regulatory (Subpart C or D), Net Ton
11812 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

28 April 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 402678
26 August 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394341
6 February 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 387492
16 June 1995 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 379484
14 January 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 363765
6 January 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 441389
6 January 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1373970
18 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 682384
8 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 362369
8 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462363
21 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359526
3 April 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 357347
30 March 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 106471
4 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 462003
12 July 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 351861

Deficiency record · 16

Documentation
Issued 6 February 1996 Resolved
SOPEP missing notification list as required by MARPOL 73/78 CHAP IV REG 26 (2) (b). The SOPEP was approved by the flag state.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Deck/Cargo
Issued 16 June 1995 Resolved
Permenantly repair wasted lube oil manifold containment located aft of mainsuperstructurent. Repairs must be completed prior to next U.S. bunker of lube oil.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Navigation
Issued 8 November 1993 Resolved
VESSEL'S VHF-FM RADIO WAS NOT CAPABLE OF TRANSMITTING OR RECEIVING VHF-FM CHANNEL 22A (157.1 MHz).
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Navigation
Issued 8 November 1993 Resolved
VESSEL'S GYRO COMPASS NOT OPERATING PROPERLY - 33 C.F.R. 164.11(r). BOARDING OFFICERS FOUND A 17 DEGREE DIFFERENCE BETWEEN THE VESSEL'S GYRO COMPASS AND IT'S MAGNETIC COMPASS.
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Navigation
Issued 8 November 1993 Resolved
VESSEL'S MAGNETIC COMPASS NOT OPERATING PROPERLY - 33 C.F.R. 164.11(r). BOARDING OFFICERS FOUND A 17 DEGREE DIFFERENCE BETWEEN THE VESSEL'S MAGNETIC COMPASS AND IT'S GYRO COMPASS._x001C_
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Navigation
Issued 8 November 1993 Resolved
VESSEL'S SECOND MARINE RADAR NOT OPERATING 33 C.F.R. 164.11(r).
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Lifesaving
Issued 8 November 1993 Resolved
Water on deck in lifeboat provisions storeroom on the 01 deck stbd side. Due to improper closure of door.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Lifesaving
Issued 8 November 1993 Resolved
Cover to storage compt. on stbd lifeboat improperly positioned. Permittingrain and water to enter compt.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Accommodation/Occupational Safety
Issued 8 November 1993 Resolved
Repair both wasted vent ducts on 02 deck stbd side.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Accommodation/Occupational Safety
Issued 8 November 1993 Resolved
Bottom three treads on ladder from main to 01 deck were wasted.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Construction/Loadline
Issued 8 November 1993 Resolved
Bottom half of WTD to battery room wasted around gasket surfaces.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Electrical
Issued 8 November 1993 Resolved
Three electric winch motor guards wasted on fantail.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Lifesaving
Issued 8 November 1993 Resolved
Both life boats have cracks in seat area fore and aft of boat. Cracks do not propagate into hull exterior. The cause is unknown and vessel providedno information on cause.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Accommodation/Occupational Safety
Issued 8 November 1993 Resolved
Ventilation duct to Bos'n stores completely wasted.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Navigation
Issued 3 April 1993 Resolved
A VIO OF 33 C.F.R. 164.33(a)(3)(ii) IN THAT THE VESSEL DID NOT HAVE THE TIDAL CURRENT TABLES PUBLICATION ONBOARD.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Navigation
Issued 3 April 1993 Resolved
A VIO OF 33 C.F.R. 164.33(a)(2)(i) IN THAT THE VESSEL DID NOT HAVE A U.S. COAST PILOT OR A FOREIGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.