MAURY USCG vessel records Sign in
← All vessels

SVENDBORG GALLANT

SVENDBORG GALLANT is a freight ship. The Coast Guard has recorded 3 inspections in 2002, along with 16 deficiencies and 2 operational controls.

Records in 2002. Most recent: inspection, 27 November 2002.

Built
Not recorded
Last inspected
27 November 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8213380 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
376799
Flag
DENMARK
—
Maury page id
psix-376799

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (2002)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2183 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

27 November 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1711724
17 October 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1695495
7 October 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1686023

Deficiency record · 16

Navigation › Emergency Steering
Issued 7 October 2002 Resolved
Rudder Angle Indicator in steering room 5 degrees off to port. 33CFR164.25(iv) Repair to the satisfaction of certificate issuing authority prior to vessel departing port. LEGACY COMPONENT DESC: Compass Reading for Emergency Steering
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 21 November 2002
Resolution: Replaced with new indicator and tested to satisfaction of class (BV).
Fire Fighting › Combustible Materials
Issued 7 October 2002 Resolved
Unknown source of oil and grease in emergency battery room. (Solas 74, II-2/2) Find source or oil and eliminate cause and clean-up, to satisfaction of certificate issuinig authority by 06NOV02.
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Cleaned and corrected by crew to satisfaction of class.
Fire Fighting › Structural Fire Protection - General
Issued 7 October 2002 Resolved
Fire extinguishers improperly mounted in steering flat and in paint locker. (Solas 74 I/11) Mount extinguishers to satisfaction of certificate issuing authority.
Action required: 705 - Other - as specified
Due 20 October 2002
Resolved 21 November 2002
Resolution: Extingusihers porperly mounted.
Fire Fighting › Combustible Materials
Issued 7 October 2002 Resolved
Inadequate engineroom housekeeping. Excessive oil, rags, open electrical boxes, dead-end wiring, batteries stowed with caps off, etc. (Solas 74, II-2/2)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 21 November 2002
Resolution: General upkeep and cleanliness enforced by crew.
Documentation › Certificates/Documents
Issued 7 October 2002 Resolved
Safety Equipment Certificate expired. (Solas 74, I/12) LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 21 November 2002
Resolution: Resolved by Flag state.
Electrical › Electrical Distribution System (service)
Issued 7 October 2002 Resolved
Improper splices/wiring runs to overhead light in steering flat (Solas 74, II-1/27) LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: reaired to the satisfaction of class (BV)
Lifesaving › Lifebuoys
Issued 7 October 2002 Resolved
No quick release for lifebuoy on bridge wing. (Solas 74 Unamended III-21/6) LEGACY COMPONENT DESC: Stowage
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Corrected by Flag state.
Electrical › Lighting (service)
Issued 7 October 2002 Resolved
Missing cover for light in head. (Solas 74 Unamended II-1/27) LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 13 October 2002
Resolved 21 November 2002
Resolution: Repaired to satisfaction of class.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 7 October 2002 Resolved
Toilets not working. (ILO 147) LEGACY COMPONENT DESC: Toilet
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: repaired to the satifaction of class.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2002 Resolved
No railing in engine room passage above main diesel engine. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of close.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2002 Resolved
Breaker handle on main switchboard for #3 s/s generator missing. LEGACY COMPONENT DESC: Hand Grab
Action required: 705 - Other - as specified
Due 20 October 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of class.
Documentation › Manuals/Policy Documentation
Issued 7 October 2002 Resolved
Publications not to date or not on board.
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Publications now onboard.
Pollution Prevention/Response › Prevention Equipment
Issued 7 October 2002 Resolved
Overboard valve for oily water separator leaking. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: reapired to the satisfation of class.
Electrical › Electric Supply System (service)
Issued 7 October 2002 Resolved
Electrical relays for reefers/freezer overheating.
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Replaced and repaired to the satisfaction of class(BV)
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2002 Resolved
Wasted piping on watermaker.
Action required: 705 - Other - as specified
Due 20 October 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of class (BV).
Construction/Loadline › Structures
Issued 7 October 2002 Resolved
Seachest wasted.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of class (BV).

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.