Records in 2002. Most recent: inspection, 27 November 2002.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Navigation › Emergency Steering
Issued 7 October 2002
Resolved
Rudder Angle Indicator in steering room 5 degrees off to port. 33CFR164.25(iv) Repair to the satisfaction of certificate issuing authority prior to vessel departing port. LEGACY COMPONENT DESC: Compass Reading for Emergency Steering
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 21 November 2002
Resolution: Replaced with new indicator and tested to satisfaction of class (BV).
Fire Fighting › Combustible Materials
Issued 7 October 2002
Resolved
Unknown source of oil and grease in emergency battery room. (Solas 74, II-2/2) Find source or oil and eliminate cause and clean-up, to satisfaction of certificate issuinig authority by 06NOV02.
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Cleaned and corrected by crew to satisfaction of class.
Fire Fighting › Structural Fire Protection - General
Issued 7 October 2002
Resolved
Fire extinguishers improperly mounted in steering flat and in paint locker. (Solas 74 I/11) Mount extinguishers to satisfaction of certificate issuing authority.
Action required: 705 - Other - as specified
Due 20 October 2002
Resolved 21 November 2002
Resolution: Extingusihers porperly mounted.
Fire Fighting › Combustible Materials
Issued 7 October 2002
Resolved
Inadequate engineroom housekeeping. Excessive oil, rags, open electrical boxes, dead-end wiring, batteries stowed with caps off, etc. (Solas 74, II-2/2)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 21 November 2002
Resolution: General upkeep and cleanliness enforced by crew.
Documentation › Certificates/Documents
Issued 7 October 2002
Resolved
Safety Equipment Certificate expired. (Solas 74, I/12) LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 21 November 2002
Resolution: Resolved by Flag state.
Electrical › Electrical Distribution System (service)
Issued 7 October 2002
Resolved
Improper splices/wiring runs to overhead light in steering flat (Solas 74, II-1/27) LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: reaired to the satisfaction of class (BV)
Lifesaving › Lifebuoys
Issued 7 October 2002
Resolved
No quick release for lifebuoy on bridge wing. (Solas 74 Unamended III-21/6) LEGACY COMPONENT DESC: Stowage
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Corrected by Flag state.
Electrical › Lighting (service)
Issued 7 October 2002
Resolved
Missing cover for light in head. (Solas 74 Unamended II-1/27) LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 13 October 2002
Resolved 21 November 2002
Resolution: Repaired to satisfaction of class.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 7 October 2002
Resolved
Toilets not working. (ILO 147) LEGACY COMPONENT DESC: Toilet
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: repaired to the satifaction of class.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2002
Resolved
No railing in engine room passage above main diesel engine. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of close.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2002
Resolved
Breaker handle on main switchboard for #3 s/s generator missing. LEGACY COMPONENT DESC: Hand Grab
Action required: 705 - Other - as specified
Due 20 October 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of class.
Documentation › Manuals/Policy Documentation
Issued 7 October 2002
Resolved
Publications not to date or not on board.
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Publications now onboard.
Pollution Prevention/Response › Prevention Equipment
Issued 7 October 2002
Resolved
Overboard valve for oily water separator leaking. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: reapired to the satisfation of class.
Electrical › Electric Supply System (service)
Issued 7 October 2002
Resolved
Electrical relays for reefers/freezer overheating.
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 21 November 2002
Resolution: Replaced and repaired to the satisfaction of class(BV)
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2002
Resolved
Wasted piping on watermaker.
Action required: 705 - Other - as specified
Due 20 October 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of class (BV).
Construction/Loadline › Structures
Issued 7 October 2002
Resolved
Seachest wasted.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2002
Resolved 21 November 2002
Resolution: repaired to satisfaction of class (BV).