MAERSK NESTON

MAERSK NESTON is a 2001 freight ship. The Coast Guard has recorded 27 inspections since 2004, most recently in April 2026, along with 9 deficiencies and 9 operational controls.

Records from 2004 to 2026. Most recent: operational control imposed, 16 April 2026.

Built
2001
Last inspected
16 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9215907 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3532
Flag
SINGAPORE
—
Maury page id
psix-37685

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (2004–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it45725 - Displacement, Metric Ton
34643 - Dead Weight, Metric Ton
26718 - Convention (Subpart B), Gross Ton
12715 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

16 April 2026 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8351001
15 April 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8351230
20 February 2026 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8311343
19 August 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8212370
15 April 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8111904
14 April 2025 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8111260
2 April 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8103949
31 March 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8100796
29 March 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8101681
29 March 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8102377
28 March 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8101123
13 January 2022 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7379898
15 November 2021 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7349044
4 November 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7342372
25 May 2021 Ballast Water Examination · PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7205377
10 October 2020 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7074890
25 June 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986675
19 April 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6940945
15 April 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939279
10 April 2020 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6938011
16 March 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6927375
4 March 2020 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6917189
13 December 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3647867
11 May 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3203520
21 May 2007 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2936060
15 April 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2908121
18 November 2004 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 2252151

Deficiency record · 9

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 November 2021 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.3 of the code and be capable of quick release from the navigation bridge. PSCO observed ring lifebuoys that weighed 2.5 KG. LSA requires those ring lifebuoys to weigh a minimum of 4 KG.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 November 2021
Resolved 13 January 2022
Resolution: Recieved satisfactory class report attesting to correction of deficiency. Class report attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2021 Resolved
Electrical installations shall be such that: the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed several "Dead End" electrical wires inside the vagiation equipment room on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 November 2021
Resolved 13 January 2022
Resolution: Recieved satisfactory class report attesting to correction of deficiency. Class report attached.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2021 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. PSCO observed that the classification society markings were only painted on the hull and not permanently marked. ICLL 66/Reg. 8 50ac
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 2 July 2021
Resolution: Plimsoll mark - the deficiency was rectified, the paint was re-applied as per satisfaction of the ABS Surveyor
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 May 2021 Resolved
The fixed fire detectionand and fire alarm system shall initiate audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. PSCO observed the visual alarm in the purifier room inoperable. 74 SOLAS 01 con. II-2/13.1.4 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2021
Resolved 10 June 2021
Resolution: The visual alarm in the purifier room was restored to the satisfaction of the ABS Surveyor attending on the 10th of June
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 25 May 2021 Resolved
Hydraulic power operated steering gear shall be providided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. PSCO observed the visual low level alarm in the steering gear room inoperable. 74 SOLAS 04 con. II-1/29.12.3 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2021
Resolved 10 June 2021
Resolution: The visual low level alarm in the Steering Gear room was restored to the satisfaction of the ABS Surveyor attending on the 10th of June.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed a leak and a temporary repair on the sea water fire fighting and wash deck line. 74 SOLAS 14 con. I/II(b) 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 10 June 2021
Resolution: The leak on the sea water and fire fighting line was stopped to the satisfaction of the ABS Surveyor attending on the 10th of June.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2020 Resolved
All external high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system, which shall include a means for collection of leakages. Diesel fuel was observed leaking at a rate of one drop every three seconds from several fuel soaked high-pressure fuel lines on the Main Diesel Engine and puddling on top of the fuel pump covers. 74 SOLAS (2001)/II-2 Reg. 15.2.6.9 15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2020
Resolved 16 March 2020
Resolution: Received satisfactory class report from ABS attesting that all "O" rings were replaced and system was witnessed operating at normal pressure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2020 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. A hand rail located next to the #1 General Service Pump had been modified so it could be detachable. This modification resulted in excessive play in the hand rail. 74 SOLAS (2004)/II-1 Reg. 26.1 15ac
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2020
Resolved 16 March 2020
Resolution: Received satisfactory class report from ABS attesting to the full replacement of the 45 liter extinquisher.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2020 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. The 45 Liter portable foam fire extinguisher had a low CO2 charge, rendering it ineffective. 74 SOLAS (2001)/II-2 Reg. 21 15ac
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2020
Resolved 16 March 2020
Resolution: Received satisfactory class report from ABS attesting to the full replacement of the 45 liter extinguisher.