Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it45725 - Displacement, Metric Ton 34643 - Dead Weight, Metric Ton 26718 - Convention (Subpart B), Gross Ton 12715 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 22
16 April 2026Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8351001
15 April 2026Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8351230
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 November 2021Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.3 of the code and be capable of quick release from the navigation bridge. PSCO observed ring lifebuoys that weighed 2.5 KG. LSA requires those ring lifebuoys to weigh a minimum of 4 KG.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 November 2021
Resolved 13 January 2022
Resolution: Recieved satisfactory class report attesting to correction of deficiency. Class report attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2021Resolved
Electrical installations shall be such that: the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed several "Dead End" electrical wires inside the vagiation equipment room on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 November 2021
Resolved 13 January 2022
Resolution: Recieved satisfactory class report attesting to correction of deficiency. Class report attached.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2021Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. PSCO observed that the classification society markings were only painted on the hull and not permanently marked. ICLL 66/Reg. 8 50ac
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 2 July 2021
Resolution: Plimsoll mark - the deficiency was rectified, the paint was re-applied as per satisfaction of the ABS Surveyor
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 May 2021Resolved
The fixed fire detectionand and fire alarm system shall initiate audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. PSCO observed the visual alarm in the purifier room inoperable. 74 SOLAS 01 con. II-2/13.1.4 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2021
Resolved 10 June 2021
Resolution: The visual alarm in the purifier room was restored to the satisfaction of the ABS Surveyor attending on the 10th of June
Hydraulic power operated steering gear shall be providided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. PSCO observed the visual low level alarm in the steering gear room inoperable. 74 SOLAS 04 con. II-1/29.12.3 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2021
Resolved 10 June 2021
Resolution: The visual low level alarm in the Steering Gear room was restored to the satisfaction of the ABS Surveyor attending on the 10th of June.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed a leak and a temporary repair on the sea water fire fighting and wash deck line. 74 SOLAS 14 con. I/II(b) 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 10 June 2021
Resolution: The leak on the sea water and fire fighting line was stopped to the satisfaction of the ABS Surveyor attending on the 10th of June.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2020Resolved
All external high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system, which shall include a means for collection of leakages. Diesel fuel was observed leaking at a rate of one drop every three seconds from several fuel soaked high-pressure fuel lines on the Main Diesel Engine and puddling on top of the fuel pump covers.
74 SOLAS (2001)/II-2 Reg. 15.2.6.9
15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2020
Resolved 16 March 2020
Resolution: Received satisfactory class report from ABS attesting that all "O" rings were replaced and system was witnessed operating at normal pressure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2020Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. A hand rail located next to the #1 General Service Pump had been modified so it could be detachable. This modification resulted in excessive play in the hand rail.
74 SOLAS (2004)/II-1 Reg. 26.1
15ac
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2020
Resolved 16 March 2020
Resolution: Received satisfactory class report from ABS attesting to the full replacement of the 45 liter extinquisher.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2020Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. The 45 Liter portable foam fire extinguisher had a low CO2 charge, rendering it ineffective.
74 SOLAS (2001)/II-2 Reg. 21
15ac
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2020
Resolved 16 March 2020
Resolution: Received satisfactory class report from ABS attesting to the full replacement of the 45 liter extinguisher.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.