← All vessels
MAERSK NESTON
MAERSK NESTON is a 2001 freight ship. The Coast Guard has recorded 27 inspections since 2004, most recently in April 2026, along with 9 deficiencies and 9 operational controls.
Records from 2004 to 2026. Most recent: operational control imposed, 16 April 2026.
- Built
- 2001
- Last inspected
- 16 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9215907 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3532
37685
Flag
SINGAPORE
—
Maury page id
psix-37685
Inspections, by type
…with no type recorded10
Years with a record
9 calendar years (2004–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it45725 - Displacement, Metric Ton
34643 - Dead Weight, Metric Ton
26718 - Convention (Subpart B), Gross Ton
12715 - Convention (Subpart B), Net Ton
34643 - Dead Weight, Metric Ton
26718 - Convention (Subpart B), Gross Ton
12715 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
16 April 2026
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8351001
15 April 2026
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8351230
20 February 2026
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8311343
19 August 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8212370
15 April 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8111904
14 April 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8111260
2 April 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8103949
31 March 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8100796
29 March 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8101681
29 March 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8102377
28 March 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8101123
13 January 2022
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7379898
15 November 2021
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7349044
4 November 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7342372
25 May 2021
Ballast Water Examination · PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7205377
10 October 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7074890
25 June 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986675
19 April 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6940945
15 April 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939279
10 April 2020
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6938011
16 March 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6927375
4 March 2020
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6917189
13 December 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3647867
11 May 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3203520
21 May 2007
ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2936060
15 April 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2908121
18 November 2004
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 2252151
Deficiency record · 9
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 November 2021
Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.3 of the code and be capable of quick release from the navigation bridge. PSCO observed ring lifebuoys that weighed 2.5 KG. LSA requires those ring lifebuoys to weigh a minimum of 4 KG.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2021
Resolved
Electrical installations shall be such that: the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed several "Dead End" electrical wires inside the vagiation equipment room on the bridge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2021
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. PSCO observed that the classification society markings were only painted on the hull and not permanently marked. ICLL 66/Reg. 8 50ac
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 May 2021
Resolved
The fixed fire detectionand and fire alarm system shall initiate audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. PSCO observed the visual alarm in the purifier room inoperable. 74 SOLAS 01 con. II-2/13.1.4 40ac
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 25 May 2021
Resolved
Hydraulic power operated steering gear shall be providided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. PSCO observed the visual low level alarm in the steering gear room inoperable. 74 SOLAS 04 con. II-1/29.12.3 40ac
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021
Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed a leak and a temporary repair on the sea water fire fighting and wash deck line. 74 SOLAS 14 con. I/II(b) 50ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2020
Resolved
All external high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system, which shall include a means for collection of leakages. Diesel fuel was observed leaking at a rate of one drop every three seconds from several fuel soaked high-pressure fuel lines on the Main Diesel Engine and puddling on top of the fuel pump covers.
74 SOLAS (2001)/II-2 Reg. 15.2.6.9
15ac
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2020
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. A hand rail located next to the #1 General Service Pump had been modified so it could be detachable. This modification resulted in excessive play in the hand rail.
74 SOLAS (2004)/II-1 Reg. 26.1
15ac
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2020
Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. The 45 Liter portable foam fire extinguisher had a low CO2 charge, rendering it ineffective.
74 SOLAS (2001)/II-2 Reg. 21
15ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.