MAURY USCG vessel records
← All vessels

LOOP RESPONDER

LOOP RESPONDER is a 1992 towing vessel. The Coast Guard has recorded 64 inspections since 1992, most recently in August 2025, along with 54 deficiencies and 4 casualty investigations between 2006 and 2022.

Records from 1992 to 2025. Most recent: inspection, 12 August 2025.

Built
1992
Last inspected
12 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 12 August 2025
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 33 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9065510
WCP9610
377002
Flag
UNITED STATES
Maury page id
psix-377002

Documentation record

Registered dimensions (L × B × D)144.0 ft × 51.5 ft × 15.0 ft
Registered tonnagegross 398 / net 344
ITC dimensions (L × B × D)144.0 ft × 51.5 ft × 15.0 ft
ITC tonnagegross 1,045 / net 313
BuilderNORTH AMERICAN SHIPBUILDG · LAROSE, LA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1045 - Convention (Subpart B), Gross Ton
398 - Regulatory (Subpart C or D), Gross Ton
313 - Convention (Subpart B), Net Ton
344 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 64

12 August 2025 COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8203041
10 March 2025 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090885
6 September 2023 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7786397
27 June 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7488502
31 May 2022 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7463865
24 January 2022 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7384891
23 January 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7523093
15 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7333388
17 August 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7035173
13 December 2019 Drydock Exam · Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6873197
20 September 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6544536
24 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6489674
9 April 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6389579
13 September 2017 MTSA Verification · Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6264616
31 May 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168689
27 July 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5954914
16 September 2015 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5719864
22 December 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5048703
9 December 2014 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5036342
24 October 2013 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4739593
14 November 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4483559
20 September 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4445701
8 June 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4336521
6 January 2012 Administration
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4234655
22 December 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4221449
1 October 2010 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3860619
16 December 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3651405
3 September 2009 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3583817
2 October 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3336992
16 August 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3037402
20 June 2007 Hull Examination · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2976858
13 April 2007 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2907184
14 December 2006 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2850007
14 December 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2864698
16 October 2006 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2803701
14 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2818828
21 October 2005 Examination of Repairs · MTSA Verification · Hull Examination · COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2377872
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501576
16 June 2005 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2392654
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293929
19 May 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2072181
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979489
16 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1847762
19 July 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1650206
10 July 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1644203
17 May 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389381
15 June 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050724
16 May 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404970
8 May 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376181
7 July 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452537
17 March 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 35858
15 March 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 122150
7 July 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431985
29 July 1997 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396770
18 July 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390578
18 July 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390295
15 August 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355400
28 July 1995 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407529
26 July 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444869
3 September 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1139021
27 July 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382615
12 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 831975
27 April 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842031
29 July 1992 Hull Examination · Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946653

Deficiency record · 54

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2025 Resolved
The required vessel, equipment, or installation plans, as listed in this subchapter, are general in character, but include all plans which normally show the intended construction and safety features coming under the cognizance of the Coast Guard. Both Voith Drives has faulty Zero Pitch indicators that didn't set off visual alarms by the engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 28 August 2025
Resolution: Videos sent showing operation of limit switch for Voith Drives.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 August 2025 Resolved
Each crew berthing area shall be equipped with information regarding vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and procedures and resources to report crimes, including sexual assault and sexual harassment. Accommodation Spaces (bathrooms) did not have the required information posted inside the berthing spaces. 46 USC 11101
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 28 August 2025
Resolution: Photos show Information Placards posted in open heads.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 June 2022 Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F. Port side fire main piping to fire monitor has multiple areas with temporary repairs. Prior to conducting standby service. 46 CFR 95.17-15(a), 46 CFR 50.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 July 2022
Resolution: Ran port side fire monitor, inspected newly installed piping; all sat, no leaks.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 27 June 2022 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and vetilators. Pimp room blower fan motor is inoperable and vent cover is not properly installed until new motor arrives. 46 CFR 92.15-10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2022
Resolution: Pump room blower fan cover was reinstalled (fan install is still pending); all sat, cover will not leak and can be closed in case of fire.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 27 June 2022 Resolved
The aforementioned information shall be kept up to date, any alteration being recorded in the applicable medium as soon as practicable. Fire & Safety plan was not up to date based on visual inspection of plan on board vessel. 46 CFR 97.36-1(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 1 July 2022
Resolution: Fire plan was updated by the captain, spotted checked a few items; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022 Resolved
At each inspection for certification, periodic inspection and at other times necessary, the inspector will determine that all fire-extingusihing requipment is in suitable condition and may require any tests necessary to determine the condition of the equipment. Portable fire extinguisher in starboard main deck locker was missing nozzle horn. 46 CFR 91.25-20(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2022
Resolution: Portable fire extinguisher in stbd main deck locker was replaced; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022 Resolved
Where fire detecting or extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. Fire pimp gauge and indicator light inoperable from operating station. 46 CFR 95.01-5(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2022
Resolution: Ran fire pump from bridge, indicator light and gage were operational; all sat.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 27 June 2022 Resolved
Vessels operated solely within one hundred nautical miles of shore must be equipped with .. A single sideband radiotelephone capable of operating on all distress and safety frequencies in the medium frequency and high frequency band listed in 80.369(a) and (b), on all the ship-to-shore calling frequencies in the high frequency bands listed in 80.369(d), and on at least four of the automated mutual-assistance vessel rescue (AMVER) system HF duplex channels (this requirement may be met by the addition of such frequencies to the radiotelephone installation required by paragraph (b) of this section). Single Sideband radiotelephone was not fully operational. 47 CFR 80.880(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2022
Resolution: Tested single sideband radio with GMDSS suite, radio and printer functioned properly (third party tech troubleshot and repaired); all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2022 Resolved
Representatives from the OSV LOOP RESPONDER reported an engine room fire that orginiated on the Port M/E resulting in a loss of propulsion and damage to areas in the engine room and engine room ventilation. Vessel must affect repairs to the Port M/E and other damaged equipment to the satisfaction of the CG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2022
Resolved 31 January 2022
Resolution: Vessel made appropriate repairs to the satisfaction of the Coast Guard.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 December 2019 Resolved
There must be an individual holding an MMC or license endorsed as Chief Engineer or other credential authorizing service as Chief Engineer employed onboard vessels of 200 GRT and over. The Chief Engineer was limited to operations on Offshore Supply Vessels.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2019
Resolved 18 January 2020
Resolution: Chief Engineer had the OSV limitation removed from his license.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 December 2019 Resolved
The general construction of the vessel shall be such as to minimize fire hazards. There was a fuel leak on the starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2019
Resolved 18 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 December 2019 Resolved
The general construction of the vessel shall be such as to minimize fire hazards. There was a fuel valve that was discovered inoperable on the port generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2019
Resolved 18 December 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 December 2019 Resolved
During preparation, launching, and recovery, each survival craft and area of water into which it is to be launched or recovered must be adequately illuminated by lighting supplied from the emergency power source. The emergency lighting did not provide illumination on the aft deck where the life-rafts would be boarded.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: E-lights installed on port and stbd main deck.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 September 2017 Resolved
Hertz Gage on #2 Switchboard stuck at 61hz.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 14 September 2017
Resolution: New hertz meter installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 13 September 2017 Resolved
Port generator missing 2nd hose clamp on un barbed pipe on jacket water system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: 2nd hose clamp installed.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 13 September 2017 Resolved
The Wire Cables that support the platform on the rescue platform is aged and splintered which will cause injury to hands.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 21 September 2017
Resolution: Cables replaced
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 September 2017 Resolved
Battery box in engine room was not secured.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: Secured battery box prior to completion of inspection.
Documentation › Markings/Placards › Garbage Placard
Issued 13 September 2017 Resolved
Marpol V placard not current.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: New placard posted prior to completion of inspection.
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 16 September 2015 Resolved
Oxygen acetylene tanks stored on aft deck 01 level with insufficient restraint and no barrier between bottles.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 17 September 2015
Resolution: Removed acetylene tanks.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 16 September 2015 Resolved
No transfer procedures or line diagram posted at fuel transfer or recovered oil controls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 17 September 2015
Resolution: Transfer procedures or line diagram posted
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 16 September 2015 Resolved
Overspeed trip being serviced on starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2015
Resolution: Overspeed trip corrected on starboard generator.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 September 2015 Resolved
Batteries for SSB in crawl space under bridge were not properly installed in a battery box and secured against shifting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 5 October 2015
Resolution: Battery boxes perminently secured and box covers installed.
Engineering › Pressure Vessel › Shell Plate
Issued 16 September 2015 Resolved
Both pressure vessels exhibited evidence of pitting/corrosion in upper portions of interior of PV's. Internal inspection insufficient. Both pressure vessels to be hydrostatically tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 11 November 2015
Resolution: UPVs hydro tested. All sat.
Engineering › Lubricating Oil Service System › Pump Prime Mover
Issued 16 September 2015 Resolved
Electric motor for backup lube oil pump for port voith drive being service at time of inspection. Tech report to be provided by vessel rep upon completion, installation, and test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 5 October 2015
Resolution: Tech report to be provided for lube oil pump electric backup motor.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 22 December 2014 Resolved
The STBD crane pedestal has had the mating flange removed due to corrosion. The flange was replaced and welded to the pedestal. Vessel did not call out CG for oversight. Vessel to have NDT done on welds with a CG Marine Inspector in attendance to witness testing. Prior to placing crane in service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 20 January 2015
Resolution: Reviewed Appleton drawing for weld. Mag particle testing was conducted no defects noted, required sheerwave for subsurface defect-3 defects identified and corrected retested no defects found.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 22 December 2014 Resolved
Due to vessel's port crane pedestal mating flange being removed and replaced the vessel must provide welder qualifications and approved welding procedures to the attending MI for review and approval prior to placing the crane back in service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 20 January 2015
Resolution: Received welder certs and Appleton Marine drawing for weld, and Sampey wrote up a proceedure for the fillet welds.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 22 December 2014 Resolved
Both of the vessel's deck cranes were removed to be rebuilt and serviced. Prior to placing the cranes back into service the vessel must conduct the 60month crane testing IAW 46CFR107.260 prior to the cranes being placed back into service. Crane testing must be witnessed by an attending CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 5 January 2015
Resolution: Witnessed crane test on both cranes. attached reports in system.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 24 October 2013 Resolved
Port generator would not trip offline from an overspeeding condition.
Condition: Improper/Lack of Maintenance
Due 25 November 2013
Resolved 25 October 2013
Resolution: Service tech able to troubleshoot problem by next day.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 October 2010 Resolved
Repair engine room ladder rail at 01 deck.
Due 2 October 2010
Resolved 1 October 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 October 2010 Resolved
Properly repair electrical splice and install proper junction box in pump room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2010
Resolved 1 October 2010
Lifesaving › Inflatable Liferafts › Capacity
Issued 30 October 2006 Resolved
Provide 100% liferaft capacity on each side of vsl within 3 months
Condition: Improper Installation
Due 30 January 2007
Resolved 22 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 30 October 2006 Resolved
Provide fixed fire extinguishing systems for recovered oil tanks & pumproom in compliance with Cg MVI Policy Ltr for Oil Spill Recovery Vsls (3-92) & 46 CFR Part 95 within 3 months.
Condition: Improper Installation
Due 30 January 2007
Resolved 12 April 2007
Resolution: Based on appeal, and citing satisfactory service this requirement is waived.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 October 2006 Resolved
Demonstrate overspeed trips for both SSGs prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2006
Resolution: Tested both generators, satisfactory.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 16 October 2006 Resolved
Demonstrate reverse power trips for both SSGs prior to sail (inop).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2006
Resolution: After repair, both SSGs tested sat.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 16 October 2006 Resolved
No record of completion of approved automation tests since 2004, engineer not using approved procedures.
Condition: Improper/Lack of Maintenance
Due 16 November 2006
Resolved 16 August 2007
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 16 October 2006 Resolved
Second licensed mate (in charge of nav watch) lacked GMDSS endorsement.
Condition: Unknown
Due 17 November 2006
Resolved 22 June 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 October 2006 Resolved
Mount emergency light at GMDSS station. Vsl crew removed existing installation after it broke.
Condition: Improper Installation
Due 17 November 2006
Resolved 22 June 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 16 October 2006 Resolved
Mount additional B-II in cargo pump room. Requires one at exit and one at pump flat.
Condition: Improper Installation
Due 17 November 2006
Resolved 17 October 2006
Resolution: Additional CO2 provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 16 October 2006 Resolved
Provide B-III for engine room.
Condition: Unknown
Due 18 October 2006
Resolved 17 October 2006
Resolution: Provided and mounted.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 October 2006 Resolved
Remove batteries from cargo pump room (hazardous location).
Condition: Unknown
Due 16 October 2006
Resolved 17 October 2006
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 16 October 2006 Resolved
Repair P/V vents for cargo tanks, 2 broken, all require adjustment.
Condition: Improper/Lack of Maintenance
Due 17 November 2006
Resolved 22 June 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2006 Resolved
Provide guard for stbd compressor belt drive and pump PTO unit on stbd side of engine room.
Condition: Unknown
Due 17 November 2006
Resolved 22 June 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 October 2006 Resolved
Gouge and weld crack beginning at exhaust bracket pass thru of bulkhead main deck, stbd side.
Condition: Unknown
Due 17 November 2006
Resolved 22 June 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 October 2006 Resolved
Remove plastic garbage can from engine room, use metal can with lid.
Condition: Improper Installation
Due 17 October 2006
Resolved 17 October 2006
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 16 October 2006 Resolved
Provide new rescue harness for man overboard platform.
Condition: Improper/Lack of Maintenance
Due 17 November 2006
Resolved 17 October 2006
Lifesaving › Line-Throwing Appliances › Lines
Issued 16 October 2006 Resolved
Provide dedicated auxiliary line fore line throwing gun.
Condition: Unknown
Due 17 November 2006
Resolved 17 October 2006
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 May 2004 Resolved
Revise Automation Test Procedures and provide for CG approval.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 25 May 2004
Engineering
Issued 19 July 2002 Resolved
Provide approved automation test procedures for vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 31 July 2002
Deck/Cargo
Issued 19 July 2002 Resolved
Install an striker plate for Stbd crane anti- to blocking device and prove proper operation of same.
Condition: Improper Installation
Due 19 August 2002
Resolved 31 July 2002
Resolution: Received fax from vsl rep
Electrical
Issued 16 May 2000 Resolved
Prior to operating ship's service generators in parallel - replace reverse power relay, #1 ship service generator switchboard and prove proper operation of same to attending marine inspector.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 7 July 1999 Resolved
DEMONSTRATE PROPER OPERATON OF BOTH SHIP SERVICE GENERATOR OVERSPEED TRIPS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 August 1999
Resolved 16 July 1999
Navigation
Issued 7 July 1999 Resolved
INSTALL AND PROVE PROPER OPERATION OF GLOBAL MARITIME DISTRESS AND SAFETY SYSTEM IN ACCORDANCE WITH 47 CFR 80 SUBPART "W" TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Electrical
Issued 7 July 1999 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH SHIP SERVICE GENERATOR REVERSE POWER RELAYS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 August 1999
Resolved 16 July 1999
Construction/Loadline
Issued 12 May 1993 Resolved
MODIFY BALLAST MANIFOLD AND PIPING SYSTEM TO BRING INTO COMPLIANCE WITH 46CFR 56.50-50(h). APPROVED PLANS MUST ALSO BE PROVIDED.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993

Casualty record · 4

14 October 2006Routine · role: Involved in a Marine Casualty · activity 2818828
14 December 2006Routine · role: Involved in a Marine Casualty · activity 2864698
9 April 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6389579
23 January 2022Routine · role: Involved in a Marine Casualty · activity 7523093
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.