LOOP RESPONDER
LOOP RESPONDER is a 1992 towing vessel. The Coast Guard has recorded 64 inspections since 1992, most recently in August 2025, along with 54 deficiencies and 4 casualty investigations between 2006 and 2022.
Records from 1992 to 2025. Most recent: inspection, 12 August 2025.
- Built
- 1992
- Last inspected
- 12 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 54 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2006–2022
Identity
986161
9065510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCP9610
377002
Flag
UNITED STATES
338575000
Maury page id
psix-377002
Inspections, by type
…with no type recorded8
Years with a record
33 calendar years (1992–2025)
The 64 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)144.0 ft × 51.5 ft × 15.0 ft
Registered tonnagegross 398 / net 344
ITC dimensions (L × B × D)144.0 ft × 51.5 ft × 15.0 ft
ITC tonnagegross 1,045 / net 313
BuilderNORTH AMERICAN SHIPBUILDG · LAROSE, LA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1045 - Convention (Subpart B), Gross Ton
398 - Regulatory (Subpart C or D), Gross Ton
313 - Convention (Subpart B), Net Ton
344 - Regulatory (Subpart C or D), Net Ton
398 - Regulatory (Subpart C or D), Gross Ton
313 - Convention (Subpart B), Net Ton
344 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCP9610MMSI 338575000 · active · voluntarily equipped · granted 10 March 2025, expires 14 February 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 64
12 August 2025
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8203041
10 March 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090885
6 September 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7786397
27 June 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7488502
31 May 2022
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7463865
24 January 2022
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7384891
23 January 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7523093
15 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7333388
17 August 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7035173
13 December 2019
Drydock Exam · Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6873197
20 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6544536
24 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6489674
9 April 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6389579
13 September 2017
MTSA Verification · Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6264616
31 May 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168689
27 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5954914
16 September 2015
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5719864
22 December 2014
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5048703
9 December 2014
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5036342
24 October 2013
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4739593
14 November 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4483559
20 September 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4445701
8 June 2012
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4336521
6 January 2012
Administration
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4234655
22 December 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4221449
1 October 2010
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3860619
16 December 2009
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3651405
3 September 2009
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3583817
2 October 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3336992
16 August 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3037402
20 June 2007
Internal Structural Exam · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2976858
13 April 2007
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2907184
14 December 2006
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2850007
14 December 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2864698
16 October 2006
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2803701
14 October 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2818828
21 October 2005
Examination of Repairs · Internal Structural Exam · Cargo Tank Internal · COI Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2377872
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501576
16 June 2005
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2392654
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293929
19 May 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2072181
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979489
16 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1847762
19 July 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1650206
10 July 2002
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1644203
17 May 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389381
15 June 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050724
16 May 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404970
8 May 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376181
7 July 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452537
17 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 35858
15 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 122150
7 July 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431985
29 July 1997
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396770
18 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390578
18 July 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390295
15 August 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355400
28 July 1995
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407529
26 July 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444869
3 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1139021
27 July 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382615
12 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 831975
27 April 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842031
29 July 1992
Inclining Experiment · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946653
Deficiency record · 54
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2025
Resolved
The required vessel, equipment, or installation plans, as listed in this subchapter, are general in character, but include all plans which normally show the intended construction and safety features coming under the cognizance of the Coast Guard. Both Voith Drives has faulty Zero Pitch indicators that didn't set off visual alarms by the engine.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 August 2025
Resolved
Each crew berthing area shall be equipped with information regarding vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and procedures and resources to report crimes, including sexual assault and sexual harassment. Accommodation Spaces (bathrooms) did not have the required information posted inside the berthing spaces.
46 USC 11101
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 June 2022
Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F. Port side fire main piping to fire monitor has multiple areas with temporary repairs. Prior to conducting standby service. 46 CFR 95.17-15(a), 46 CFR 50.05-10(a)
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 27 June 2022
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and vetilators. Pimp room blower fan motor is inoperable and vent cover is not properly installed until new motor arrives. 46 CFR 92.15-10(a)
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 27 June 2022
Resolved
The aforementioned information shall be kept up to date, any alteration being recorded in the applicable medium as soon as practicable. Fire & Safety plan was not up to date based on visual inspection of plan on board vessel. 46 CFR 97.36-1(c)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022
Resolved
At each inspection for certification, periodic inspection and at other times necessary, the inspector will determine that all fire-extingusihing requipment is in suitable condition and may require any tests necessary to determine the condition of the equipment. Portable fire extinguisher in starboard main deck locker was missing nozzle horn. 46 CFR 91.25-20(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022
Resolved
Where fire detecting or extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. Fire pimp gauge and indicator light inoperable from operating station. 46 CFR 95.01-5(a)
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 27 June 2022
Resolved
Vessels operated solely within one hundred nautical miles of shore must be equipped with .. A single sideband radiotelephone capable of operating on all distress and safety frequencies in the medium frequency and high frequency band listed in 80.369(a) and (b), on all the ship-to-shore calling frequencies in the high frequency bands listed in 80.369(d), and on at least four of the automated mutual-assistance vessel rescue (AMVER) system HF duplex channels (this requirement may be met by the addition of such frequencies to the radiotelephone installation required by paragraph (b) of this section). Single Sideband radiotelephone was not fully operational. 47 CFR 80.880(b)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2022
Resolved
Representatives from the OSV LOOP RESPONDER reported an engine room fire that orginiated on the Port M/E resulting in a loss of propulsion and damage to areas in the engine room and engine room ventilation. Vessel must affect repairs to the Port M/E and other damaged equipment to the satisfaction of the CG prior to departure.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 December 2019
Resolved
There must be an individual holding an MMC or license endorsed as Chief Engineer or other credential authorizing service as Chief Engineer employed onboard vessels of 200 GRT and over. The Chief Engineer was limited to operations on Offshore Supply Vessels.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 December 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards. There was a fuel leak on the starboard generator.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 December 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards. There was a fuel valve that was discovered inoperable on the port generator.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 December 2019
Resolved
During preparation, launching, and recovery, each survival craft and area of water into which it is to be launched or recovered must be adequately illuminated by lighting supplied from the emergency power source. The emergency lighting did not provide illumination on the aft deck where the life-rafts would be boarded.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 September 2017
Resolved
Hertz Gage on #2 Switchboard stuck at 61hz.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 13 September 2017
Resolved
Port generator missing 2nd hose clamp on un barbed pipe on jacket water system.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 13 September 2017
Resolved
The Wire Cables that support the platform on the rescue platform is aged and splintered which will cause injury to hands.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 September 2017
Resolved
Battery box in engine room was not secured.
Documentation › Markings/Placards › Garbage Placard
Issued 13 September 2017
Resolved
Marpol V placard not current.
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 16 September 2015
Resolved
Oxygen acetylene tanks stored on aft deck 01 level with insufficient restraint and no barrier between bottles.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 16 September 2015
Resolved
No transfer procedures or line diagram posted at fuel transfer or recovered oil controls.
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 16 September 2015
Resolved
Overspeed trip being serviced on starboard generator.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 September 2015
Resolved
Batteries for SSB in crawl space under bridge were not properly installed in a battery box and secured against shifting.
Engineering › Pressure Vessel › Shell Plate
Issued 16 September 2015
Resolved
Both pressure vessels exhibited evidence of pitting/corrosion in upper portions of interior of PV's. Internal inspection insufficient. Both pressure vessels to be hydrostatically tested.
Engineering › Lubricating Oil Service System › Pump Prime Mover
Issued 16 September 2015
Resolved
Electric motor for backup lube oil pump for port voith drive being service at time of inspection. Tech report to be provided by vessel rep upon completion, installation, and test.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 22 December 2014
Resolved
The STBD crane pedestal has had the mating flange removed due to corrosion. The flange was replaced and welded to the pedestal. Vessel did not call out CG for oversight. Vessel to have NDT done on welds with a CG Marine Inspector in attendance to witness testing. Prior to placing crane in service.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 22 December 2014
Resolved
Due to vessel's port crane pedestal mating flange being removed and replaced the vessel must provide welder qualifications and approved welding procedures to the attending MI for review and approval prior to placing the crane back in service.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 22 December 2014
Resolved
Both of the vessel's deck cranes were removed to be rebuilt and serviced. Prior to placing the cranes back into service the vessel must conduct the 60month crane testing IAW 46CFR107.260 prior to the cranes being placed back into service. Crane testing must be witnessed by an attending CG Marine Inspector.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 24 October 2013
Resolved
Port generator would not trip offline from an overspeeding condition.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 October 2010
Resolved
Repair engine room ladder rail at 01 deck.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 October 2010
Resolved
Properly repair electrical splice and install proper junction box in pump room.
Lifesaving › Inflatable Liferafts › Capacity
Issued 30 October 2006
Resolved
Provide 100% liferaft capacity on each side of vsl within 3 months
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 30 October 2006
Resolved
Provide fixed fire extinguishing systems for recovered oil tanks & pumproom in compliance with Cg MVI Policy Ltr for Oil Spill Recovery Vsls (3-92) & 46 CFR Part 95 within 3 months.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 October 2006
Resolved
Demonstrate overspeed trips for both SSGs prior to sailing.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 16 October 2006
Resolved
Demonstrate reverse power trips for both SSGs prior to sail (inop).
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 16 October 2006
Resolved
No record of completion of approved automation tests since 2004, engineer not using approved procedures.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 16 October 2006
Resolved
Second licensed mate (in charge of nav watch) lacked GMDSS endorsement.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 October 2006
Resolved
Mount emergency light at GMDSS station. Vsl crew removed existing installation after it broke.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 16 October 2006
Resolved
Mount additional B-II in cargo pump room. Requires one at exit and one at pump flat.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 16 October 2006
Resolved
Provide B-III for engine room.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 October 2006
Resolved
Remove batteries from cargo pump room (hazardous location).
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 16 October 2006
Resolved
Repair P/V vents for cargo tanks, 2 broken, all require adjustment.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2006
Resolved
Provide guard for stbd compressor belt drive and pump PTO unit on stbd side of engine room.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 October 2006
Resolved
Gouge and weld crack beginning at exhaust bracket pass thru of bulkhead main deck, stbd side.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 October 2006
Resolved
Remove plastic garbage can from engine room, use metal can with lid.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 16 October 2006
Resolved
Provide new rescue harness for man overboard platform.
Lifesaving › Line-Throwing Appliances › Lines
Issued 16 October 2006
Resolved
Provide dedicated auxiliary line fore line throwing gun.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 May 2004
Resolved
Revise Automation Test Procedures and provide for CG approval.
Engineering
Issued 19 July 2002
Resolved
Provide approved automation test procedures for vessel.
Deck/Cargo
Issued 19 July 2002
Resolved
Install an striker plate for Stbd crane anti- to blocking device and prove proper operation of same.
Electrical
Issued 16 May 2000
Resolved
Prior to operating ship's service generators in parallel - replace reverse power relay, #1 ship service generator switchboard and prove proper operation of same to attending marine inspector.
Electrical
Issued 7 July 1999
Resolved
DEMONSTRATE PROPER OPERATON OF BOTH SHIP SERVICE GENERATOR OVERSPEED TRIPS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Navigation
Issued 7 July 1999
Resolved
INSTALL AND PROVE PROPER OPERATION OF GLOBAL MARITIME DISTRESS AND SAFETY SYSTEM IN ACCORDANCE WITH 47 CFR 80 SUBPART "W" TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Electrical
Issued 7 July 1999
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH SHIP SERVICE GENERATOR REVERSE POWER RELAYS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 12 May 1993
Resolved
MODIFY BALLAST MANIFOLD AND PIPING SYSTEM TO BRING INTO COMPLIANCE WITH 46CFR 56.50-50(h). APPROVED PLANS MUST ALSO BE PROVIDED.
Casualty record · 4
14 October 2006Routine · role: Involved in a Marine Casualty · activity 2818828
14 December 2006Routine · role: Involved in a Marine Casualty · activity 2864698
9 April 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6389579
23 January 2022Routine · role: Involved in a Marine Casualty · activity 7523093
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.