Records from 1992 to 2026. Most recent: inspection, 20 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
20 May 2026
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8385518
13 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8345816
22 April 2025
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8123513
21 July 2024
Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7963674
22 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7928880
26 April 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7709836
16 March 2022
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7403221
3 May 2021
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7380036
14 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7179849
15 March 2021
Plan Review "T" Boat
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7156578
31 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7021274
10 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6709798
23 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6680172
7 May 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6402476
14 June 2017
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6133906
25 August 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5982933
3 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5863269
5 July 2012
Deficiency Check · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4365847
17 March 2009
Hull Examination · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3413607
21 May 2002
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1608267
1 May 2001
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1063773
22 June 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1050648
3 May 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1406741
4 May 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 795165
5 May 1998
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 792370
6 May 1997
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115152
7 May 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 875465
25 April 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414439
22 December 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1161537
9 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 865119
3 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 170521
3 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 225498
26 May 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1443473
15 June 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1150328
24 May 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 827879
28 April 1993
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1436751
10 July 1992
Plan Review "T" Boat · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 952847
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2026
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel was missing the 40-B:C Fire Extinguisher. Owner to obtain proper fire extinguisher for vessel and provide proof to MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2026
Resolution: Received proof of fire extinguisher on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel did not have required 40BC portable fire extinguisher. Provide required and approved 40BC portable fire extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: 40B placed on boat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. NFPA F.7.2.4 If the inspection of a rechargeable fire extinguisher model reveals any physical deficiencies such as damage, corrosion, low-pressure reading, missing parts, obstructed nozzle, illegible operating instructions, prior use, or broken tamper seals, such deficiencies indicate the need for immediate maintance and servicing of the fire extinguisher. Inspector found the two available portable fire extinguishers missing tamper seals. Service the two portable fire extinguishers with a qualified servicing organization and re-install tamper seals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Extinguishers were serviced
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2025
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Fireboy was found to be past due annual service requirements. Service Fireboy with a qualified servicing organization.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Fireboy was serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicator at operating station did not light to the operation of the automatic bilge pump, but lit for manual operation as intended. Vessel must have visual indicator at the operating station when the automatic bilge pump is operating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2025
Resolved 5 May 2025
Resolution: Bilge pump light is working.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 July 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to the provision for a sea worthy hull. Operator reported striking a rock on the Lower Salmon River at Green Canyon Rapid. Vessel is to be hauled out at have satisfactory repairs conducted prior to the carriage of passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2025
Resolution: MI Verified all repairs, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2024
Resolved
Propulsion engine started when the Inspectors were testing the fume detector.
Action required: 10 - Deficiency Rectified
Resolved 30 May 2024
Resolution: Operator repaired electrical issue.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 22 May 2024
Resolved
Fuel oil (gas) sprayed out of the fuel line to the starboard engine when the engines started.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2024
Resolved 30 May 2024
Resolution: O/O replaced fuel hose.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2021
Resolved
A pre-engineered fixed gas fire extinguisher system must be installed in accordance with the manufacturer's instructions. Fireboy charge indicator indicates "recharge." Ensure Fireboy is installed in accordance with manufacturer's instructions to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2021
Resolved 3 May 2021
Resolution: Email received providing satisfactory evidence of fix fire system working as designed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 April 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge. Vessel's engine room bilge alarm is inoperable. Ensure bilge alarm in engine room is operable to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2021
Resolved 3 May 2021
Resolution: Email received providing satisfactory evidence that high water bilge alarm works as designed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 April 2021
Resolved
Each small battery installation must be protected from falling objects. Both batteries in the engine room are missing covers. Protect batteries from falling objects to satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2021
Resolved 3 May 2021
Resolution: An email was received providing satisfactory evidence of battery protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2019
Resolved
An emergency switch must be provided in the normally ungrounded main supply conductor from a battery. The battery switch onboard was inoperable. Vessel required to proper operation of battery switch to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 10 June 2019
Resolution: Marine Inspector received pictures of the new switch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2019
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Ring buoy was not marked with reroreflective tape. Vessel required to apply retroreflective tape to ring buoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 10 June 2019
Resolution: Owner installed SOLAS tape to life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 23 April 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. The consumables found in the first aid kit were expired. Vessel required to place into service consumables which are equivalent and valid.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 10 June 2019
Resolution: Received documentation from Owner indicating the consumables had been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2018
Resolved
Provide Coast Guard Approved Ring Buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating an approved ring buoy has been placed into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2018
Resolved
Repair/Replace starboard fuel oil emergency cut off valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating the remote fuel shut-off valve is operating as intended.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2018
Resolved
Provide two(02) portable flashlights.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating two (02) portable flashlights have been placed into service onboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2018
Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating the first aid kit was updated.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 May 2018
Resolved
Repair and prove proper operation of navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating the navigation lights onboard the vessel were repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2018
Resolved
Provide two(02) 2.5 gallon fire buckets, with lanyards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating two fire buckets, with lanyards have been placed into service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2018
Resolved
Provide emergency check off procedures.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating that emergency procedures specific to the vessel have been placed into service.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 May 2018
Resolved
Provide anchor or grappling hook and line (ground tackle).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating that ground tackle has been placed into service on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2018
Resolved
Provide one (01) 2-A fire extinguisher for the accommodation space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 14 July 2018
Resolution: Marine Inspector received statement from the vessel owner, supported by pictures, indicating that a 2-A fire extinguisher was placed into service onboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2018
Resolved
Provide proof of payment of user fees.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 10 June 2019
Resolution: 2017 User Fees were paid, FINCEN applied them to 2018 User Fees. Owner is working with FINCEN to ensure all debts are paid.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 June 2017
Resolved
Have both portable fire extinguishers and fixed-fire system (FireBoy) serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2017
Resolved 14 July 2017
Resolution: Owner provide fire extinguisher servicing report.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 June 2017
Resolved
Repair bilge pump float switch.
Due 14 July 2017
Resolved 14 July 2017
Resolution: Confirmed with owner that the float switch had been repaired.
Communications › Alarms/Indicators › General Alarm
Issued 14 June 2017
Resolved
Provide audible alarm for vapor (gasoline) detection in the machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2017
Resolved 14 July 2017
Resolution: Owner replaced existing vapor/fume detector with a new unit; test sat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 June 2017
Resolved
Owner to provide proof of enrollment in a certified DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2017
Resolved 14 July 2017
Resolution: Vessel's owner provided proof of enrollment in a third-party administrated consortium.
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2017
Resolved
Replace life-ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2017
Resolved 14 July 2017
Resolution: Owner purchased new ring-buoy and line.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2017
Resolved
Replaced expired consumables in first aid kit.
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 14 July 2017
Resolution: Expired items in first aid kit were replaced.
Fire Fighting › Combustible Materials › Ceilings
Issued 14 June 2017
Resolved
Remove expanded foam from engine room hatches. (Used as a sound barrier, but not flame retardant.)
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2017
Resolved 14 July 2017
Resolution: Owner sent pictures showing that the expanded foam had been removed from the engine hatches.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 July 2012
Resolved
Have all portable fire extinguishers serviced.
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 20 July 2012
Resolution: Owner e-mailed proof of service.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 5 July 2012
Resolved
Have fixed fire system serviced.
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 20 July 2012
Resolution: Owner e-mailed proof of service.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2012
Resolved
Renew expired first aid kit items.
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 20 July 2012
Resolution: Owner provided proof of purchase for expired items.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 July 2012
Resolved
Make bilge alarm operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2012
Resolved 20 July 2012
Resolution: Owner e-mailed statement that the bilge alarm was operable.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 July 2012
Resolved
Provide proof of current state registration new owners name.
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 20 July 2012
Resolution: Owner e-mailed proof of registration
Engineering
Issued 3 May 2000
Resolved
Install emergency fuel shut-off valves for fuel tanks IAW 46CFR182.455 (b) (4).
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 3 May 2000
Resolved
Install audible alarm for fixed FIREBOY halon system in the engine room IAW46CFR181.420
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 3 May 2000
Resolved
Lower fume detector to approx 6" above the bilge bottom IAW 46CFR182.480 (e).
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 3 May 2000
Resolved
Update emergency checkoff list for area and vessel operations IAW 46CFR185.510 & .512
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Accommodation/Occupational Safety
Issued 6 May 1997
Resolved
PROVIDE EMERGENCY CHECKOFF MEETING 46 CFR 185.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Documentation
Issued 6 May 1997
Resolved
PROVIDE AND MOUNT POLLUTION PLACARD.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Documentation
Issued 6 May 1997
Resolved
PROVIDE DOCUMENTATION THAT ANNUAL DRUG TESTING DATA HAS BEEN SUBMITTED TO CG HEADQUARTERS.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Accommodation/Occupational Safety
Issued 6 May 1997
Resolved
PROVIDE FIRST AID KIT MEETING OR EXCEEDING 46 CFR 160.041.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Engineering
Issued 6 May 1997
Resolved
PROVIDE DRIP PANS FOR EACH FUEL FILTER. EACH PAN SHALL BE FITTED WITH 30 X30 MESH METALIC FLAME SCREEN.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 6 May 1997
Resolved
PROVIDE 4 ADDITIONAL CG APPROVED TYPE I PFD'S-ADULT SIZED.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Construction/Loadline
Issued 6 May 1997
Resolved
MARK BOW (PORT & STBD) AND TRANSOM WITH VESSEL'S NAME. ON TRANSOM, ALSO INCLUDE HAILING PORT. LETTERING TO BE MINIMUM 4 INCHES.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 9 September 1994
Resolved
Make permanent repairs to temporary patches welded over holes in vessel bottom plate. Inspection of patches shall be conducted daily to ensure integrity of repairs until permanent repairs are completed and witnessed byCoast Guard inspector.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Fire Fighting
Issued 28 April 1993
Resolved
REFILL FIXED HALON SYSTEM (PORTSIDE) IN ENGINE COMPARTMENT. PASSENGERS MAY_x001C_NOT BE CARRIED UNTIL REFILLED.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Lifesaving
Issued 28 April 1993
Resolved
PROVIDE TWO CHILD PFD'S, UNTIL PROVIDED, ONLY 1 CHILD MAY BE CARRIED.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993