Inspection history · 18
25 February 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8302574
12 August 2025
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8209006
15 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8094164
7 January 2025
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8084683
7 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7907429
7 February 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7866335
15 March 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7655295
17 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7622747
20 September 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7562750
8 March 2022
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7408366
11 January 2021
Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7122938
3 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6966151
2 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6654692
5 March 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6635079
21 February 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6359175
3 April 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117159
8 March 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100084
4 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844048
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 March 2025
Resolved
...A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces.. Vessels constructed of wood must... provide bilge level alarms in all watertight compartments except small buoyancy chambers." Bilge high-level alarms were inoperable in: Port Stern, port bow, and starboard bow compartments.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O repaired and installed bilge high level alarms. MI Tested each alarm satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 March 2025
Resolved
"...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector..." The vessel's rep was unable to provide documentation attesting to the proper servicing of the installed firefighting equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O recieved servicing report. MI verified the validity of the report.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 March 2025
Resolved
"A vessel on a lakes, bays, and sounds, or rivers route must carry: three hand red flare distress signals...Three hand orange smoke distress signals" Vessel had on board, three hand red flare distress signals and two hand orange smoke signals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O received new distress signals totaling 6 red hand flares.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 15 March 2025
Resolved
"As appropriate for the intended voyage, a vessels must carry adequate and up-to-date charts of large enough scale to make safe navigation possible." The vessel's representative was unable to provide detailed information on the updates received to the electronic charts. The most recent update we were able to find was in 2021.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O updated electronic charts satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2025
Resolved
"This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably" A grounding cable was found disconnected in the port side steering compartment on the deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O satisfactorily secured and attached all cables in the steering compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 March 2025
Resolved
"Equipment specification for life floats and buoyant apparatus... Paddle. Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant." Both life floats were missing their paddles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O aquired and secured approved paddles to the life floats.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 15 March 2025
Resolved
"The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI." There were not a sufficient number of testing devices on board, and the ones that were available were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2025
Resolved 28 March 2025
Resolution: O/O received an adequate number of valid alcohol swabs and updated their address with their consortium.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2025
Resolved
Bonding wire on both fuel fill hoses found broken. Renew fill neck bonding.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 4 March 2025
Resolution: Received photos of properly installed bonding.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 May 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in servicable condition must be repaired or replaced.
The aft life-float was found worn on the outer collar edge.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 10 May 2024
Resolution: Received photos from O/O showing repairs to damaged life float.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 March 2022
Resolved
Certificate of Documentation (COD) is expired. Provide valid COD.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 March 2022
Resolution: COD issued. Expires January 31, 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2022
Resolved
Life float painter improperly installed. Line passed through cage will not allow the weak link to function properly. Install painter assembly IAW manufacturers instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2022
Resolution: Painter arrangement corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 October 2021
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The vessel's lifefloat is not fitted with paddle or light.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 19 October 2021
Resolution: Vessel operator sent photos of lifeline, pendants, two paddles, painter and light attached to life float.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 January 2021
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel was not fitted with a compass.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 19 October 2021
Resolution: Vessel sent photo of magnetic compass mounted to primary operating station.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 January 2021
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Vessel has no record of abandon ship/MOB drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 March 2023
Resolved 19 October 2021
Resolution: Vessel sent photos of logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 January 2021
Resolved
Each PFD must have at least 31 sq in of retroreflective material on its front and back side. Vessel must ensure retroreflective tape has been approved under 46CFR164.018.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 19 October 2021
Resolution: Vessel sent photos of newly purchased retro-reflective tape approved under 46CFR164.018.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 February 2018
Resolved
Cracked floating water light and missing dog to secure cap. Replace floating light. 46CFR180.70
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 28 February 2018
Resolution: Received picture of replacement buoy light.
Engineering › Lubricating Oil Service System › Gauge
Issued 21 February 2018
Resolved
L/O pressure guage for STBD engine at operating station not functioning properly. Repair or replace guage. 46CFR182.20-5
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 7 March 2018
Resolution: Received video from [name withheld] of operating oil pressure gauge.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 April 2017
Resolved
STBD engine exhaust riser hose single clamped. Double clamp hose connections.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 31 August 2017
Resolution: STBD exhaust riser hose found double clamped.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 April 2017
Resolved
R/W system hose clamp failing on stbd engine/wasted through. replace double hose clamps on R/W system.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 31 August 2017
Resolution: R/W system hose clamp failing on stbd engine replaced in kind.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 April 2017
Resolved
Ground strap between F/O tanks and fill caps loose on both sides. Provide proper bonding between tanks and caps. Old T 46CFR182.20-30
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 31 August 2017
Resolution: Ground strap between F/O tanks and fill caps loose on both sides found properly tightened.
Lifesaving › Lifefloat › Platform
Issued 8 March 2017
Resolved
15 MAN LIFE FLOAT HAS SIGNIFICANT WATER INTRUSION AND REQUIRES REPAIR OR REPLACEMENT. [IN ACCORDANCE WITH 46 CFR 180.207(D)] PRIOR TO OPERATING MORE THAN 1 MILE FROM SHORE, REPAIR OR REPLACE LIFE FLOAT. IF REPAIR DESIRED, PROVIDE PROPOSAL TO OCMI. - 46 CFR 180.207(D) - PRIOR TO OPERATION MORE THAN ONE (1) MILE FROM SHORE
Action required: 705 - Other - as specified
Resolved 13 March 2017
Resolution: Owners approved removal of lifefloats, and restriction of vessel to no more than one mile from land, in accordance with 46 CFR 180.207(d).
Lifesaving › Rescue Boat › Carriage Requirement
Issued 8 March 2017
Resolved
PERSON IN WATER (PIW) RECOVERY ARRANGEMENTS NOT ADEQUATE FOR HELPLESS VICTIM. [IN ACCORDANCE WITH 46 CFR 180.210(B)(2)] PROVIDE SLING OR OTHER ARRANGEMENT FOR RECOVERY OF HELPLESS PIW. - 46 CFR 180.210(B)
Due 8 April 2017
Resolved 23 March 2017
Resolution: Installed lifesling and ladder clips.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 4 April 2016
Resolved
Uninsulated section of pipe was found between engine and jacketed portion of exhaust as required by 46CFR182.15-15(b)(3). Cover with lagging to the satisfaction of the attending Maring Inspector.
Due 7 April 2016
Resolved 10 May 2016
Resolution: Added lagging to exposed pipe.
Construction/Loadline › Structures › End Bulkhead
Issued 4 April 2016
Resolved
Fireblocks between engine spacees were not installed properly as required by 46CFR181.420(c). Perminantly reattach fire blocks between engine spaces to the satisfaction of attending Marine Inspector.
Condition: Improper Installation
Due 4 May 2016
Resolved 24 May 2016
Resolution: Reinstalled blocking between spaces in a manor that was perminant.