Records from 1992 to 2025. Most recent: inspection, 8 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
8 September 2025
Hull Examination · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8229596
5 February 2025
Examination of Repairs · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8074412
4 September 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7996195
15 June 2023
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7701180
21 June 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7472709
16 June 2021
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7224756
5 June 2019
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6703405
5 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6435539
5 June 2017
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6167467
13 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5907947
22 June 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4356396
18 July 2011
Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4072363
15 July 2009
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3535336
13 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247450
4 June 2007
Hull Examination · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2950944
27 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2692194
20 June 2005
COI Inspection · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2396225
7 July 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2123786
19 June 2003
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1820851
19 June 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1632996
23 July 2001
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1465673
24 July 2000
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1452697
22 November 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1427749
23 July 1999
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1103129
2 March 1999
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799290
11 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1130532
24 July 1997
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1123060
16 June 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 878195
13 July 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1417668
3 August 1993
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 842787
16 July 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1466848
25 September 1992
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1253206
16 July 1992
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 937942
10 July 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 937944
30 June 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 935966
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Label new life jackets with name of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2025
Resolved 22 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Provide donning instructions for life jackets on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2025
Resolved 22 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 September 2025
Resolved
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part:(1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed hull exam date as indicated on COI. Credit hull exam must be issued prior to carrying passengers. Hull exam scheduled for 11Sep25.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2025
Resolution: Conducted hull/ISE exam. Issued dry dock credit.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 4 September 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel missing posted emergency instructions near operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2024
Resolved 18 September 2024
Resolution: Operator posted emergency instructions
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 September 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have nautical publications on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 18 September 2024
Resolution: Rcvd objective evidence for pubs.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 16 June 2021
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a SMI shall comply with subchapter A of 4.06. Company does not evidence have a DAPI program.
46CFR185.212
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 18 June 2021
Resolution: Observed documentation of chemical reenrollment.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2021
Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10, which require the extinguishers be mounted w/ approved brackets. The two extinguishers are not stored utilizing the approved brackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 18 June 2021
Resolution: Witnessed the new brackets installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2021
Resolved
At least one ring life buoy must be fitted w/ a lifeline. The lifeline is absent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 18 June 2021
Resolution: Confirmed the installation of the brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2021
Resolved
Watertight shall be attached to the lanyard with a corrosion-resistant clip. The lanyard does not have a clip attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 18 June 2021
Resolution: Observed the clip was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2019
Resolved
A positive control shut off valve must be installed at the hull penetration for all electrical submersible bilge pumps. No valve found at hull penetration. Provide required valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2019
Resolved 24 June 2019
Resolution: Positive shutoff valve installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2019
Resolved
Child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 3 of the 4 required child sized life jackets where not present or suitable for service. Provide a total of 4 child sized life jackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 24 June 2019
Resolution: 04 new child sized lifejackets procured and stowed onboard vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 June 2019
Resolved
Electrical equipment exposed to the weather must be watertight. A hole was found in the operating station console that would allow water to enter the console and directly come into contact with the main distribution of the vessels electrical system. Seal hole in the operating station console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 24 June 2019
Resolution: Weather tight plate and gasket installed sealing hole in console.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2019
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Rail directly behind the operating station is loose in its mounting and will not support the required weight. Make repairs to rail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 24 June 2019
Resolution: New hardware installed. Handrail now meets the requirements of 46 CFR 177.900.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 June 2019
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information.
(1) Date of the training; and
(2) General description of the training topics.
No records of firefighting or man overboard drills available. Provide vessel log with properly documents drills at intervals of no greater than every 3 months.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 24 June 2019
Resolution: Drill log provided for vessel with properly logged fire and MOB drills.
Engineering › Bilge Water Management System › Pump
Issued 5 June 2018
Resolved
Manual bilge pump was not available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 July 2018
Resolution: Photo evidence of bilge pump.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 June 2018
Resolved
Center pax seat was broken and had exposed screws sticking up. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 July 2018
Resolution: Photo evidence of repaired seat.
Lifesaving › Lifebuoys › Serviceable
Issued 5 June 2018
Resolved
RLB was not serviceable. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 July 2018
Resolution: Photo evidence of 24" ring buoy with light/line.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 5 June 2017
Resolved
Portable light at operating station was inoperable.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Rcvd email showing correction of def.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 5 June 2017
Resolved
Vsl rep could not produce original vsl registration.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Rcvd email showing correction of def.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2016
Resolved
Portable bilge pump does not have sufficient length of hose to adequately dewater. Lengthen hose to satisfy dewatering requirements.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 23 June 2016
Resolution: Appropriate length of hose was installed to portable bilge pump allowing ability to dewater.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 June 2016
Resolved
Markings are insufficient. Repair as needed to properly mark lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 23 June 2016
Resolution: Lifering marked satisfactorily.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 June 2007
Resolved
replace bracket for fire extinquisher.
Due 26 June 2007
Resolved 26 June 2007
Resolution: replaced sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 7 July 2004
Resolved
Provide two properly mounted B-II portable fire extinguishers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2004
Resolved 8 July 2004
Resolution: Received fax copy of receipt for 2 10-pound dry chemical extinguishers.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 July 2004
Resolved
Prove proper operation of bilge alarm visual indicator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 22 July 2004
Resolution: Received fax copy of invoice for new alarm indicator.
Lifesaving › Lifebuoys
Issued 19 June 2003
Resolved
Replace Ring Buoy
Condition: Unknown
Due 18 July 2003
Resolved 8 July 2003
Resolution: O/O purchased new Ring Buoy
Navigation › Piloting/Steering
Issued 19 June 2002
Resolved
Properly install a comapss with a light. LEGACY COMPONENT DESC: Magnetic Compass
Due 3 July 2002
Resolved 3 July 2002
Electrical › Electrical Distribution System (service)
Issued 19 June 2002
Resolved
Install chaffing gear around the ground cable in the eng. compartment. LEGACY COMPONENT DESC: Cable
Due 3 July 2002
Resolved 3 July 2002
Engineering › Fuel Oil Service System
Issued 19 June 2002
Resolved
Replace the worn hose in the engine compartment and install chaffing gear around new hose. LEGACY COMPONENT DESC: Hose
Due 3 July 2002
Resolved 3 July 2002
Lifesaving › Lifebuoys
Issued 19 June 2002
Resolved
Provide a light for the ring bouy. LEGACY COMPONENT DESC: Self-igniting Lights
Due 3 July 2002
Resolved 3 July 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 19 June 2002
Resolved
Provide servicing for the fixed and portable fire extinguishers.
Due 3 July 2002
Resolved 3 July 2002
Construction/Loadline
Issued 24 July 2000
Resolved
MAKE VESSEL AVAILABLE WITH CREW TO CONDUCT SATISFACTORY UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 July 2000
Resolved 28 July 2000
Lifesaving
Issued 24 July 2000
Resolved
PROVE FULL COMPLIANCE WITH THE FEDERAL DRUG TESTING REQUIREMENTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 July 2000
Resolved 28 July 2000
Engineering
Issued 24 July 2000
Resolved
LABEL THE STARBOARD EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 24 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 23 July 1999
Resolved
MAKE TEMPORARY REPAIR TO CRACKS IN BOTTOM PLATING PORT AND STARBOARD SIDE_x001C_ PRIOR TO RETURNING THE VESSEL TO SERVICE.
Condition: Unknown
Due 30 July 1999
Resolved 23 July 1999
Construction/Loadline
Issued 23 July 1999
Resolved
CROP AND PROPERLY INSERT CRACKED BOTTOM PLATING, PORT AND STARBOARD SIDE, INWAY OF TEMPORARY REPAIR PORT AND STARBOARD SIDE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Lifesaving
Issued 13 July 1994
Resolved
REPLACE 12 EXPIRED DISTRESS SIGNAL FLARES (6 ORANGE, 6 RED)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Lifesaving
Issued 16 July 1993
Resolved
PROVIDE PROOF OF ENROLLMENT IN A PRE-EMPLOYMENT AND RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1992
Resolved
OBTAIN PORTABLE EMERGENCY LIGHTS.
Condition: Unknown
Due 15 August 1992
Resolved 15 August 1992
Documentation
Issued 16 July 1992
Resolved
OBTAIN AND POST FCC RADIO OPERATORS LICENSE.
Condition: Unknown
Due 15 August 1992
Resolved 15 August 1992
Documentation
Issued 16 July 1992
Resolved
MAKE UP AND POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 15 August 1992
Resolved 15 August 1992
Lifesaving
Issued 16 July 1992
Resolved
OBTAIN AND MOUNT PROPER AUTOMATIC FLOAT LIGHT FOR LIFE RING.
Condition: Unknown
Due 16 July 1992
Resolved 16 July 1992
Documentation
Issued 16 July 1992
Resolved
OBTAIN AND POST OIL DISCHARGE PLACARD.
Condition: Unknown
Due 15 August 1992
Resolved 15 August 1992
Documentation
Issued 16 July 1992
Resolved
OBTAIN AND POST FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 15 August 1992
Resolved 15 August 1992