Records from 1992 to 2003. Most recent: inspection, 20 March 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
20 March 2003
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1757309
28 March 2002
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1493799
21 April 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1429533
11 May 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1049784
24 March 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 816689
23 June 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1192064
23 March 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 780809
11 May 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1125802
2 April 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1125730
21 August 1997
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394817
17 March 1997
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1094141
22 March 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425715
24 March 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374238
15 March 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359748
17 March 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379760
15 January 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 826415
6 November 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1260541
10 September 1992
Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 947604
Operations/Management › Drug and Alcohol Testing
Issued 28 March 2002
Resolved
Provide proof of chemical/drug testing program prior to the carriage of any passengers. 46 CFR 16 LEGACY COMPONENT DESC: Testing, Random
Condition: Unknown
Due 28 April 2002
Resolved 27 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 March 2002
Resolved
Update all expired first aid kit items prior to the carriage of passengers. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Due 28 April 2002
Resolved 27 June 2002
Documentation › Certificates/Documents
Issued 28 March 2002
Resolved
Provide valid state registration prior to any vessel operations. 46 CFR 67.7 & 67.9 LEGACY COMPONENT DESC: State Registration
Condition: Unknown
Due 28 April 2002
Resolved 27 June 2002
Electrical › Electric Supply System (service)
Issued 28 March 2002
Resolved
Correct all wiring shorts in electrical system. Ensure that the fume detector, high level bilge alarm, and stbd-side exhaust blower all work prior to the carriage of passengers. 46 CFR 176.806 & 46 CFR 183.340 LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 28 April 2002
Resolved 27 June 2002
Fire Fighting › Fixed Fire Detection System
Issued 28 March 2002
Resolved
Repair loose connections in fire detection system so alarm sounds when the fixed halon system discharges and both exhaust blowers shutdown. Complete prior to the carriage of passengers. 46 CFR 181.420 LEGACY COMPONENT DESC: Power Supply
Condition: Improper/Lack of Maintenance
Due 28 April 2002
Resolved 27 June 2002
Lifesaving › Lifejacket/PFD (Type II)
Issued 28 March 2002
Resolved
Provide retro-reflective tape on all life-jackets. Only use solas approved tape. 46 CFR 185.604 LEGACY COMPONENT DESC: Retroreflective Material
Condition: Placed in Improper Service
Due 28 April 2002
Resolved 27 June 2002
Engineering
Issued 21 April 2001
Resolved
Repair emergency fuel cutout device. Repair prior to the carriage of passengers.
Condition: Unknown
Due 21 April 2001
Resolved 22 November 2002
Resolution: Cleared per [name withheld].
Fire Fighting
Issued 21 April 2001
Resolved
Provide audible alarm for fixed fire extinguishing system.
Condition: Unknown
Due 21 April 2001
Resolved 22 November 2002
Resolution: Cleared per [name withheld]
Fire Fighting
Issued 21 April 2001
Resolved
Lower fume detector to approx 10 inches from bilge.
Condition: Unknown
Due 21 April 2001
Resolved 22 November 2002
Resolution: Cleared as per [name withheld].
Construction/Loadline
Issued 21 April 2001
Resolved
Repair boot on steering cables to make engine compartment fume/vapor tight.
Condition: Unknown
Due 21 April 2001
Resolved 22 November 2002
Resolution: Cleared as per [name withheld].
Lifesaving
Issued 21 April 2001
Resolved
Provide 2 adult life jackets. Complete prior to having 18 passengers or limit capacity to only 16 passengers.
Condition: Unknown
Due 21 April 2001
Resolved 22 November 2002
Resolution: Cleared as per [name withheld].
Lifesaving
Issued 21 April 2001
Resolved
Provide life jacket donning placard.
Condition: Unknown
Due 21 April 2001
Resolved 22 November 2002
Resolution: Cleared as per [name withheld].
Construction/Loadline
Issued 24 March 2000
Resolved
WELD FRACTURED FILLET WELD ON FRAME BOTTOM STARBOARD SIDE UNDER FUEL TANK AFT AND UNDER ENGINE STARBOARD SIDE.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Lifesaving
Issued 24 March 2000
Resolved
MARK ALL LIFEJACKET STOWAGE WITH NUMBER OF LIFEJACKETS.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Engineering
Issued 24 March 2000
Resolved
PROVIDE FLAME SCREEN FOR STARBOARD DRIP PAN UNDER FUEL FILTER.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Construction/Loadline
Issued 24 March 2000
Resolved
PROVIDE INDICATOR LIGHT FOR AUTO BILGE PUMP TO SHOW WHEN BILGE PUMP IS AUTOMATIC PUMPING.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Engineering
Issued 23 March 1999
Resolved
Renew the fuel filter drip pan flame screen.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Lifesaving
Issued 23 March 1999
Resolved
Provide a life jacket donning placard.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Lifesaving
Issued 23 March 1999
Resolved
Provide 2 additional adult size life jackets type I.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Unknown
Issued 23 March 1999
Resolved
Provide replacment aspirin/eye wash, and burn cream for the expired ones.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Unknown
Issued 23 March 1999
Resolved
Provide emergency check off list.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Lifesaving
Issued 23 March 1999
Resolved
Properly mark life jacket stowage locations to include the number in each compartment.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Fire Fighting
Issued 2 April 1998
Resolved
REPLACE FIXED EXTINGUISHING SYSTEM GAS CYLINDER.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Engineering
Issued 17 March 1997
Resolved
PROVIDE DRAIN PANS FOR FUEL FILTERS. TO BE FITTED WITH 30 X 30 MESH, CORROSION RESISTANT METALIC FLAME SCREEN.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Lifesaving
Issued 17 March 1997
Resolved
PROVIDE FIRST AID KIT MEETING OR EQUIVALENT TO 46 CFR 160.041.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Lifesaving
Issued 24 March 1995
Resolved
Provide and post emergency check off procedures.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
Service portable fire extinguishers and provide 1 additional B-I.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Lifesaving
Issued 24 March 1995
Resolved
Remove duct tape from blower hose and replace w/ aluminized tape.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Construction/Loadline
Issued 24 March 1995
Resolved
Repair fracture in transom in way of dive platform support.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 24 March 1995
Resolved
Prove operation of fuel supply shut-off valve.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 24 March 1995
Resolved
Provide and post pollution placard.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Lifesaving
Issued 10 September 1992
Resolved
PUT VESSEL NAME ON ALL LIFE PRESERVERS WITH AT LEAST ONE INCH LETTERS.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Documentation
Issued 10 September 1992
Resolved
PROVIDE DOCUMENTATION OF A DRUG TESTING PROGRAM FOR ALL CREW MEMBERS._x001C_
Condition: Unknown
Due 10 September 1992