Records from 2016 to 2024. Most recent: inspection, 30 July 2024.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 15.4 ft × 6.9 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 1992
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVENICE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
30 July 2024
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7949764
15 August 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7769183
30 August 2022
Examination of Repairs · Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7500744
18 May 2021
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7171972
23 June 2020
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6968018
23 July 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6744939
2 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6498256
5 July 2018
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6467143
29 June 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6189326
16 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5834535
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2024
Resolved
S and L. All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Power bilge pump inoperable. Electric clutch would not engage.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 August 2024
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2024
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Floating light attached to the ring life buoy inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2024
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2024
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Generator prime mover has an oil leak from the oil pan.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 August 2024
Resolution: Repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 July 2024
Resolved
Cowls or scoops shall be kept open at all times except when the stress of weather is such as to endanger the vessel if the openings are not temporarily closed. Starboard engine room ventilation did not have an operable means of securing the closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2024
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 July 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The port engine room hatch has deteriorated foam gasket on sealing edge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 August 2024
Resolution: Repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 July 2024
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI identified missing guards on rotating components for the power bilge pump driven by the starboard engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2024
Resolution: Installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 30 July 2024
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Owner did not have an FCC license available at time of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2024
Resolution: Permit supplied to CG.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 September 2023
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets with attached lanyard to the satisfaction of the cognizant [name withheld] observed vessel with incorrect size buckets and only 02 onboard. Add appropriate equipment to the satisfaction of attending MI.
46CFR181.610
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2023
Resolution: Added appropriate fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 September 2023
Resolved
Each rescue boat and ring life buoy must be marked with type II retro-reflective material. MI observed markings on ring life buoy to not be reflective. Replace to the satisfaction of attending MI.
46CF185.604 (i)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2023
Resolution: Replaced retroreflective tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023
Resolved
When the exhaust cooling system is separate from the engine cooling system, a suitable warning device shall be provided to indicate any failure. MI observed warning device not operable on both port and starboard engines. Repair to the satisfaction of the attending MI.
46CFR182.20-15
46CFR182.15-15(b)(5)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2023
Resolution: Received video of satisfactory operation and activation of alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 September 2023
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port. MI observed life float severely cracked, lines degraded, and not in a float free configuration.
46CFR185.700(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2023
Resolution: Received satisfactory photographs of new lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 August 2019
Resolved
Marine Inspectors found wasted/worn line around basket of lifefloat. Replace to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2019
Resolved 14 August 2019
Resolution: Received email with attached photos clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2019
Resolved
Marine Inspectors found 02 fuel leaks near fuel shutoff and fuel fill. Repair to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2019
Resolved 14 August 2019
Resolution: Received photos attesting to proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 August 2019
Resolved
Marine Inspectors found wasted cover/housing on generator. Repair/replace to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2019
Resolved 14 August 2019
Resolution: Received photos attesting to proper repair.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 March 2016
Resolved
Failure to make vessel available for annual inspection within 3 months before or after each anniversary date of the COI.
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 2 August 2018
Resolution: Vessel was available for annual inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 March 2016
Resolved
Failure to make vessel available for drydock examinations and internal structural examinations required by this section.
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 2 August 2018
Resolution: Vessel was available for drydock/ISE.