GREEN GUATEMALA is a 1991 freight ship. The Coast Guard has recorded 18 inspections since 2016, most recently in May 2025, along with 13 deficiencies — 2 with no resolution recorded — and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 15 May 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it7743 - Convention (Subpart B), Gross Ton 4113 - Convention (Subpart B), Net Ton 7726 - Dead Weight, Ton 12885 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
15 May 2025PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8126289
24 February 2025Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8084017
16 October 2024PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8019668
The structue, machinery and equipment of a cargo ship shall be subject to... a minimum of two inspections of the outside of the ships bottom during any five year period. One of two required surveys of the ships bottom exceeds more than five years.
74 SOLAS920)I/10(a)(v), Code 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2025
Resolution: PSC NOLA received a class report from issuing entity satisfying the requirement
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 15 May 2025Resolved
The oil record book part 1 shall be completed on each occasion on a tank to tank basis if appropriate, whenever any of the following machinery space operations take place: collection and disposal of oil residues (sludge). PSCO observed multiple missing weekly soundings of the Sludge Tank L.O. Purifier.
MARPOL I/17.2.3, Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 5 June 2025
Resolution: PSC NOLA received a class report from issuing entity satisfying the requirement
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2025No resolution recorded
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed fire detector covered with a bag in engineers workshop.
74 SOLAS(20) II-2/14.2.1.1.2, Code 10c
Action required: 10 - Deficiency Rectified
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2025No resolution recorded
Electrical installations shall be such that: electrical services essential for safety will be ensured under various emergency conditions... PSCE observed 02 lights on deck that were extinguished and inoperable.
74 SOLAS(04) II-1/40.1.2, Code 10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 October 2024Resolved
PSCO observed a 15cm crack penetrating the door frame, bulkhead and self closing door of the engine room fire boundary.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 24 February 2025
Resolution: Recieved class survery documenting repairs of deficiency with pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2024Resolved
Unapproved temporary repair was identified on cooling water line on Generator #1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2024
Resolved 24 February 2025
Resolution: Recieved class survery documenting repairs of deficiency with pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 13 March 2024Resolved
All items of the rescue boat equipment shall be secured within the rescue boat by lashings, storage in lockers or compartments, storage in brackets or similar mounting arrangenments, or other suitable means. PSCO observed that the rescue boat equipment was not stowed within the rescue boat but was stored in a container nearby. The container was attached to the ship and would not be able to be moved to the rescue boat.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 24 February 2025
Resolution: Recieved class survery documenting repairs of deficiency with pictures.
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed substantial amount of cracking in the cement deck in CO2 room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 February 2025
Resolution: Recieved class survery documenting repairs of deficiency with pictures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 13 March 2024Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed that the deck line was painted white, the same color as the ships hull.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2024
Resolution: Ships crew painted the deck line black on a contrasting black background.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 October 2020Resolved
Rapid recovery of the rescue boat shall be possible when loaded with its full compliment of persons and equipment. PSCO noted that rescue boat davit motor controller was inoperable. 74SOLAS(97) III/16.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 October 2020
Resolved 13 October 2020
Resolution: Vessels crew was able to bring rescue boat davit motor controller into a working condition.
Engineering › Compressed Air System (start air) › Compressor
Issued 15 February 2017Resolved
01 1499 SOLAS 74 (14 CONS.)I/11 40C THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. AIR COMPRESSOR FOR STARTING MAIN ENGINE WAS OVER HEATING AND A PORTABLE FAN WAS BEING USED FOR COOLING OF THE COMPRESSOR.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 October 2020
Resolution: Vessel removed portable fan used for cooling the compressor.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 February 2017Resolved
02 2035 SOLAS 74 (14CONS.)II-2/15.24.1 40C FIRE CONTROL PLAN SHALL BE UP TO DATE. FIRE CONTROL PLAN INDICATED THERE ARE SELF-CLOSING DEVICES ON THE GALLEY DOORS, IN WHICH THEY ARE NOT INSTALLED.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 October 2020
Resolution: Vessel updated fire control plan to show actual equipment installed on vessel.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 June 2016Resolved
2299 - When operating a vessel on a body where the discharge of sewage is prohibited by the EPA, the opertor must secure each type I or type II MSD in a manner which prevents discharge of sewage." Seacock was closed but unlocked, with the handle still in place. 33CFR159.7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016
Resolution: Deficiency rectified on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.