Records from 2006 to 2026. Most recent: inspection, 23 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 23
23 April 2026
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8382770
24 March 2026
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8323319
25 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8059652
3 June 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7925794
9 February 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7863392
9 November 2023
Damage Survey · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7822921
9 November 2023
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7823909
24 May 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7695692
3 August 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7528584
18 May 2022
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7453508
18 September 2021
In-Service Inspection · Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7315002
19 February 2021
Deficiency Check · COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7142945
28 August 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7046499
13 August 2020
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7031972
11 December 2019
Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6872172
20 July 2018
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6485217
7 November 2017
DAPI Audit · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6302187
29 March 2017
In-Service Inspection · DAPI Audit · Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6114064
29 March 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6198866
20 February 2016
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 5819251
17 February 2016
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 5817144
17 February 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5843563
8 February 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5840618
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2026
Resolved
STBD AFT high water alarm has no visual only audible alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2026
Resolved
Post life jacket donning placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 April 2026
Resolved
Mark water tight container with flares "DISTRESS SIGNALS".
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2026
Resolved
Renew lanyards on 2 fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 23 April 2026
Resolved
Update drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2026
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 6 March 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 March 2025
Resolved
While testing Nav. Lights found that the anchor light is inoperable. Vessel currently does not work after sunset.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 6 March 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 March 2025
Resolved
Master of vessel is required to have a FCC operators license. Provide a copy of the FCC operator lic. to MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 6 March 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 March 2025
Resolved
Owner needs to gt a updated list of employees that are in his drug constortium. Provide MI updated list from keys consortium of all employees involved with the company.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 6 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 June 2024
Resolved
Failed to conduct annual inspection within the 90 day window before and 90 day window after the anniversary date of the COI. Must conduct annual inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 November 2023
Resolved
Vessel was involved and an incident where vessel hit home owners dock creating damage to both vessel and dock and Master failed to notify anyone. Must submit repair plan for all damage to vessel for approval prior to any work being done.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2023
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 9 November 2023
Resolved
Grey water tank is open on top causing the full tank to spill into the bilge. Pump out tank, clean bilges and make repairs to the tank.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2023
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 November 2023
Resolved
Hydrostatic release for EPIRB is good for two yrs from date of installation. Hydrostatic release was marked for expiration on DEC 2026. Must provide documentation of when Hydrostatic release was installed or replace hydrostatic release with new and mark accordingly. Vessel restricted to 1 nautical mile from shore
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2023
Resolved 12 December 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2023
Resolved
Vessels name is missing on both port and starboard side hulls. Must place vessels name on both outboard sides of the hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2023
Resolved 12 December 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 November 2023
Resolved
First aid kit was found with expired aspirin. Must replace expired aspirin
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2023
Resolved 12 December 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 May 2022
Resolved
First aid kit had expired/missing items. Must replace all expired and missing items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 19 July 2022
Resolution: bought new first aid kit that meets 160.041 requirements
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 May 2022
Resolved
Drug and alcohol program paperwork is missing. Must provide proof of current enrollment for all crew members.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 19 July 2022
Resolution: Provided proof of meeting all requirements for the Drug and Alcohol program
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2021
Resolved
Owner called stating they were replacing the port outboard powerhead. Must conduct sea trials prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2021
Resolved 2 November 2021
Resolution: Installed a new(used with 180 hours)powerhead. Conducted sea trials and tested kill switch, all SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2021
Resolved
Received picture of vessel in drydock with damage on STBD hull. Report was that the vessel ran aground on a reef. Must conduct drydock and ISE inspection prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2021
Resolved 28 October 2021
Resolution: Vessel's STBD hull was repaired
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2021
Resolved
19 FEB 2021: Called vessel rep [name withheld] to discuss the vessel REEF ROAMER. The COI anniversary date is 07 NOV and vessel has not conducted an annual inspection with in the 90 day period. There for the COI is no longer valid and will need to conduct a new COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2021
Resolved 2 March 2021
Resolution: Conducted COI Inspection
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2021
Resolved
Mast light not working. Must conduct repairs and test to satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2021
Resolved 3 March 2021
Resolution: New bulb, installed, Tested SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2021
Resolved
Stern Nav light lens is completely frosted over and barely able to see a couple feet away. Must make repairs to meet the 2 mile visibility requirement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 12 March 2021
Resolution: Owner/ Operator submitted image of replaced stern light lens with functional light.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 February 2021
Resolved
[name withheld] does not hace a FCC operators permit. Must have FCC operators permit in order to operate the vessel.
47 CFR 13
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 3 April 2021
Resolution: Owner/ Operator submitted evidence attesting to the issuance of the captain's FCC radio operator's permit.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 August 2020
Resolved
Grind out and submit a repair proposal for all identified areas. All four areas identified with chalk.
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 31 August 2020
Resolution: Repair proposal accepted and witnessed final repairs made using west systems. All repairs made satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2020
Resolved
Your vessel requires a dry-dock inspection every 2 yrs. Your last dry-dock inspection was July 2018 and next inspection was supposed to be no later that July 31st 2020. You must have a dry-dock inspection completed to the satisfaction of attending Coast Guard Marine Inspector prior to carrying passengers.
46 CFR 176.600
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2020
Resolved 28 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 December 2019
Resolved
Provide proof of certificate of documentation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2020
Resolution: Proof of COD was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 December 2019
Resolved
Life float has cracks and damage, repair, paint and stencil name on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2020
Resolution: Life float has been repaired and stenciled name and capacity on both sides.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 December 2019
Resolved
Forward port high water visual alarm is extinguished. Repair/Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2019
Resolution: Forward port high water visual alarm was renew with a newly purchased alarm.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 December 2019
Resolved
VHF must have vessels MMSI# input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: New FCC license was provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 December 2019
Resolved
Print local section of light list and coast pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2020
Resolution: Local section of light list and coast pilot have been provided on board the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 December 2019
Resolved
Create new logs for drills and safety gear and EPIRB tests.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2020
Resolution: New logs have been created for drills, safety gear and EPIRB test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 December 2019
Resolved
Multiple hand rails are loose. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2019
Resolution: All hand rails were adjusted, tightened, and outboard handrails were backed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 December 2019
Resolved
Forward starboard bilge pump auto is broken. Repair/Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2019
Resolution: Forward starboard bilge pump was renew with a newly purchases float switch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2017
Resolved
Vessel mast step is severly wasted, and has cracks in the ball and socket.
Action required: 705 - Other - as specified
Resolved 30 July 2018
Resolution: New mast step was built, and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 November 2017
Resolved
1 child PFD was found to be wasted and no longer servicable.
Action required: 10 - Deficiency Rectified
Resolved 21 November 2017
Resolution: New pfd was provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 November 2017
Resolved
FWD STBD hull bilge visual alarm is expired. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 21 November 2017
Resolution: Visual alarm light was repaired.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 November 2017
Resolved
Magnetic compass light is not wired. Repair/renew.
Action required: 10 - Deficiency Rectified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Light was repaired, and tested. all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 November 2017
Resolved
Vessel must have a log book to track training and life float maintenance. Provide a new log.
Action required: 10 - Deficiency Rectified
Due 21 November 2017
Resolved 21 November 2017
Resolution: A new log was provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 November 2017
Resolved
FWD Stbd bow has strike damage, grind area and repair.
Action required: 10 - Deficiency Rectified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Area was ground back and repaired with new epoxy, and several layers of biaxel fiberglass cloth.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2017
Resolved
FWD Port hull bilge alarm visual indicator is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: New alarm system was installed and tested. all sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 April 2017
Resolved
Vessel is missing one of the required child size PFD. Provide new PFD.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: New PFD was provided and marked.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 April 2017
Resolved
PFD storage is not marked with number and size. Marke per CFR.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: All PFD storage was properly marked.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 7 April 2017
Resolved
Port engine tach is inoperable. Repair/renew.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: New Tach was installed and tested. All sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2017
Resolved
Wiring under console is loose, and has multiple deadends. Clean up, remount and clear all deadends.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Dead ends were removed and all wiring was re-mounted.
Fire Fighting › Fire Bucket › Availability
Issued 7 April 2017
Resolved
Vessel is missing 3 fire buckets. Provide.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: New fire buckets were provided and marked.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 April 2017
Resolved
FCC safety Radio cert is expired. Renew.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: NEw FCC Cert was provided.
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 April 2017
Resolved
Magnetic compass is broken. Renew.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: New compass was installed and tested, All sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 April 2017
Resolved
All vessel Charts and navigation publications are expired. Renew or update.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: New Charts and publications were provided.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 April 2017
Resolved
Vessel does not have a life jacket donning placard.Provide and post.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Donning placard was posted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2017
Resolved
Several handrail stanchions are loose. Repair/replace.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Railing was repaired and is all sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 March 2017
Resolved
Vessel failed to complete bi-annual hull exam and annual safety inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2017
Resolution: Completed hull exam and annual inspection.