Records from 1995 to 2000. Most recent: inspection, 28 February 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
28 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275305
4 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429338
1 April 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 427155
28 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 406291
3 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 376899
29 March 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 376768
Electrical
Issued 28 February 2000
No resolution recorded
VESSEL TO REPAIR MUTIPLE SMALL FUEL LEAKS ON INJECTOR LINES ON ALL GENERATORS.
Condition: Unknown
Due 28 March 2000 — due date passed with no resolution recorded
Electrical
Issued 28 February 2000
No resolution recorded
#1 SHIP SERVICE DEISEL GENERATOR HEAD GASKET ON #7 CYLINDER LEAKING JACKET WATER AT A STEADY STREAM.
Condition: Unknown
Due 28 February 2000 — due date passed with no resolution recorded
Unknown
Issued 1 April 1999
Resolved
There was excessive oil on, the deck and machinery, in the engineroom and steering space. (SOLAS 74 REG.I/11)
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Fire Fighting
Issued 1 April 1999
Resolved
The vessel could not demonstrate proper operation of the emergency fire pump, because the crew kept running the main pump to gain adequate pressure. After approx. 20 min the steering space filled with smoke from aleak in the emergency fire pump's exhaust pipe.
Condition: Unknown
Due 6 April 1999
Resolved 9 April 1999
Documentation
Issued 1 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 April 1999
Resolved 9 April 1999
Navigation
Issued 1 April 1999
Resolved
The vessel failed to have a current/correct chart onboard for the area transited.
Condition: Unknown
Due 6 April 1999
Resolved 9 April 1999
Lifesaving
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH SOLAS CHAPTER III REGULATION 31 INSUFFICENT NUMBER OF LIFEBOUYS, 6 REQUIRED, ONE WAS WASTED AND REPLACED WITH NEW LIFEBOUY.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995
Lifesaving
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH SOLAS CHAPTER II-2, REGULATION 2, IMPROPER STOWAGE OF FLAMMABLE PAINTS AND THINNERS IN ENGINE ROOM.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Fire Fighting
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH SOLAS CHAPTER II-2 INSUFFICENT FIREHOSES ON DECK AND IN ENGINE ROOM.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Engineering
Issued 29 March 1995
Resolved
CG BOARDING OFFICER OBSERVED FUEL OIL VENT FLAME SCREENS WASTED.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Engineering
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH 33CFR155.320(a) VESSEL DID NOT HAVE A FIXED CONTAINER AROUND FUEL OIL VENTS.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Documentation
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH 46CFR42.13-40 VESSEL DID NOT HAVE A VISABLE LOADLINE.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Navigation
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH SOLAS CHAPTER II-1 REGULATION 29 VESSEL DID NOT ANY TYPEOF RAISED DECK FOR EMERGENCY STEERING PURPOSES.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Navigation
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH 33CFR164.33(a)(1)(ii) VESSEL DID NOT HAVE CHARTS CURRENTLY CORRECTED.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Lifesaving
Issued 29 March 1995
Resolved
IN ACCORDANCE WITH SOLAS CHAPTER II REGULATION 31 INSUFFICENT MAKE OF LIFEBOUY. MARKER LIGHT ON LIFEBOUY INOPERABLE, WAS REPLACED WITH NEW LIGHT_x001C_
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995