Records from 1992 to 2010. Most recent: inspection, 13 October 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
13 October 2010
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3869222
2 August 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2734017
26 April 2005
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2343414
15 July 2004
Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2134510
9 June 2004
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2093745
5 May 2004
Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2060073
20 August 2003
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1882186
23 July 2003
Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1854651
6 March 2003
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1753285
20 August 2002
Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1663761
29 March 2002
Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1599101
27 April 2001
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1426631
24 April 2001
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1062207
12 June 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 819533
27 April 2000
COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1381897
13 March 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432269
10 January 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 814245
28 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 795330
20 September 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391104
1 December 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 806524
12 November 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805796
14 September 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 799379
30 January 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1390704
19 December 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1116730
19 December 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388475
19 November 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 775809
5 December 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1091175
27 February 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077425
29 November 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192382
12 October 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 211879
12 October 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882808
1 April 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857033
21 December 1993
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160835
23 September 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154938
10 September 1993
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846925
1 September 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832409
3 September 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251822
5 August 1992
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1466283
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 15 July 2004
Resolved
Provide proof of master's valid FCC radio operator permit.
Condition: Unknown
Due 18 October 2004
Resolved 26 April 2005
Resolution: Not required for domestic voyages.
Operations/Management › Drills/Instruction › Fire
Issued 15 July 2004
No resolution recorded
Provide proof of required crew training as per 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Pump
Issued 15 July 2004
No resolution recorded
Provide one portable bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Ventilation
Issued 5 May 2004
Resolved
Repair vent grill @ engine room entrance.
Condition: Unknown
Due 14 May 2004
Resolved 11 May 2004
Resolution: Completed.
Construction/Loadline › Structures
Issued 5 May 2004
Resolved
Crop/renew to good metal stern bulwark at main deck level as marked. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 26 May 2004
Resolution: Complete.
Construction/Loadline › Structures
Issued 5 May 2004
Resolved
Crop/renew bulkhead @ engine room entrance to good metal. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 11 May 2004
Resolution: Completed.
Construction/Loadline › Structures
Issued 5 May 2004
Resolved
Repair or replace two doors leading to foredeck and hose test for USCG marine inspector. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 9 June 2004
Resolution: Doors repaired; witnessed satisfactory hose test.
Engineering › Bilge Water Management System
Issued 5 May 2004
Resolved
Replace last section of fire/bilge overboard hose in engine room. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 11 May 2004
Resolution: Completed.
Construction/Loadline › Penetrations
Issued 5 May 2004
Resolved
Replace port shaft packing hardware (NO SAIL). LEGACY COMPONENT DESC: Bottom Plug Packing
Condition: Unknown
Due 7 May 2004
Resolved 14 May 2004
Resolution: Complete.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 5 May 2004
Resolved
Replace missing belt cover on A/C unit.
Condition: Unknown
Due 14 May 2004
Resolved 11 May 2004
Resolution: Completed.
Electrical › Lighting (service)
Issued 5 May 2004
Resolved
Repair light fixture in fuel tank room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 14 May 2004
Resolved 11 May 2004
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment
Issued 5 May 2004
Resolved
Repair collar/leaks at fill connection atop MSD tank (NO SAIL). LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Condition: Improper/Lack of Maintenance
Due 7 May 2004
Resolved 26 May 2004
Resolution: Complete.
Accommodation/Occupational Safety › Potable Water System
Issued 5 May 2004
Resolved
Repair hold down strapping for potable water tank.
Condition: Unknown
Due 14 May 2004
Resolved 14 May 2004
Resolution: Complete.
Electrical › Electrical Distribution System (service)
Issued 5 May 2004
Resolved
Repair wiring on potable water pump with compression fittings as needed. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 20 May 2004
Resolution: Completed.
Accommodation/Occupational Safety › Ventilation
Issued 5 May 2004
Resolved
Replace broken window in fwd starboard door on main deck. LEGACY COMPONENT DESC: Window
Condition: Damaged By Earlier Event
Due 1 June 2004
Resolved 26 May 2004
Resolution: Complete.
Accommodation/Occupational Safety › Potable Water System
Issued 5 May 2004
Resolved
Replace missing fill cap to potable water line. LEGACY COMPONENT DESC: Fill
Condition: Unknown
Due 1 June 2004
Resolved 26 May 2004
Resolution: Complete.
Documentation › Certificates/Documents
Issued 23 July 2003
Resolved
Post valid original C.O.D. on board vessel. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 20 August 2003
Resolved 20 August 2003
Resolution: C.O.D. posted.
Documentation › Logs/Records
Issued 23 July 2003
Resolved
Establish crew training/drill log as required by 46 CFR 185.420. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Condition: Improper/Lack of Maintenance
Due 20 August 2003
Resolved 20 August 2003
Resolution: Logs provided.
Engineering › Bilge Water Management System
Issued 23 July 2003
Resolved
Power vacuum dry standing water in compartment voids #1 & 2 and engine room.
Condition: Improper/Lack of Maintenance
Due 20 August 2003
Resolved 20 August 2003
Resolution: All spaces clear of standing water.
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 July 2003
Resolved
Replaced expired medications and provide one wire splint for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 20 August 2003
Resolved 20 August 2003
Resolution: Meds renewed; splint provided.
Accommodation/Occupational Safety › Ventilation
Issued 23 July 2003
Resolved
Replace broken window in galley. LEGACY COMPONENT DESC: Window
Condition: Unknown
Due 20 August 2003
Resolved 20 August 2003
Resolution: Window replaced.
Electrical › Lighting (service)
Issued 23 July 2003
Resolved
Repair lighting in lazzarette. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 20 August 2003
Resolved 20 August 2003
Resolution: Repaired and tested sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 23 July 2003
Resolved
Provide proper brackets for fire extinguishers as needed and provide one portable extinguisher at engine room entrance. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 20 August 2003
Resolved 20 August 2003
Resolution: Brackets installed; extinguisher placed at E/R entrance.
Electrical › Electrical Distribution System (service)
Issued 29 August 2002
Resolved
Remove bundle (approx 20) dead ended wires in overhead of E/R above stbd main engine. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: Unused wires electrically insulated.
Electrical › Electric Generation Source (service)
Issued 29 August 2002
Resolved
Install covers on all battery boxes. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: All new battery boxes installed.
Electrical › Electrical Distribution System (service)
Issued 29 August 2002
Resolved
Remove dead ended wire from bulkhead in front of stbd main engine. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: Wires properly insulated.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 August 2002
Resolved
Properly support exhaust pipes port side of e/r. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Due 9 September 2002
Resolved 6 September 2002
Resolution: Metal straps installed in overhead frames. Repairs sat.
Lifesaving › Lifejacket/PFD (General)
Issued 29 August 2002
Resolved
Properly label storage room for Life jackets and Fire Extinquishers. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 9 September 2002
Resolved 6 September 2002
Resolution: Storage labelled.
Accommodation/Occupational Safety › Occupational Safety
Issued 29 August 2002
Resolved
Install latch on storage room door.
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: Repairs sat.
Electrical › Electrical Distribution System (service)
Issued 20 August 2002
Resolved
Properly secure all Starting Batterys and replace all starting battery cables. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: Repairs sat.
Electrical › Electrical Distribution System (service)
Issued 20 August 2002
Resolved
Remove red dead ended wire from over center starting battery. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 5 September 2002
Resolved 29 August 2002
Fire Fighting › Fire Pumps
Issued 20 August 2002
Resolved
Properly mount bilge/fire pump and attached capaciter.
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: Pump/moter replaced in kind and properly secured on platform.
Electrical › Electrical Distribution System (service)
Issued 20 August 2002
Resolved
Repair loose wires to outlet on E/R Ladder. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 5 September 2002
Resolved 6 September 2002
Resolution: Repairs sat.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 August 2002
Resolved
Properly secure CO2 cylinder in Soda Room.
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 6 September 2002
Resolution: Cylinder secured.
Communications › Audible Communications
Issued 20 August 2002
Resolved
Provide Ships Bell LEGACY COMPONENT DESC: Bell
Condition: Improper/Lack of Maintenance
Due 5 September 2002
Resolved 6 September 2002
Resolution: Proper bell installed ivo wheelhouse.
Communications › Audible Communications
Issued 20 August 2002
Resolved
Prove proper operation of PA Sytem.
Condition: Improper/Lack of Maintenance
Due 5 September 2002
Resolved 5 March 2003
Resolution: Satisfactory test on both decks complete.
Electrical › Electrical Distribution System (service)
Issued 20 August 2002
Resolved
Install cover on Shore tie connection Stbd side. LEGACY COMPONENT DESC: Shore Connection Box
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 5 March 2003
Resolution: Cover with captive device installed.
Operations/Management › Drills/Instruction
Issued 20 August 2002
Resolved
Conduct MOB Drill. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 6 September 2002
Resolution: Drill sat.
Electrical › Electrical Distribution System (service)
Issued 20 August 2002
Resolved
Remove dead ended white wire from under E/R Ladder. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 5 September 2002
Resolved 29 August 2002
Engineering › Shafting/Propeller Arrangements
Issued 29 March 2002
Resolved
Replace port and starboard cutless bearings. LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2002
Engineering › Steering Gear System
Issued 29 March 2002
Resolved
Repack P & S rudder bearings LEGACY COMPONENT DESC: Rudder Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2002
Engineering › Bilge Water Management System
Issued 29 March 2002
Resolved
Secure wiring on the bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2002
Engineering › Sea-water System (primary cooling)
Issued 29 March 2002
Resolved
provide chaff gear on rww water hose IWO air intake on the SSG. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2002
Engineering › Sea-water System (primary cooling)
Issued 29 March 2002
Resolved
Replace double clamps as needed. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 4 April 2002
Engineering › Shafting/Propeller Arrangements
Issued 29 March 2002
Resolved
Repack P & S shaft bearings. LEGACY COMPONENT DESC: Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 4 April 2002
Engineering › Fuel Oil Service System
Issued 29 March 2002
Resolved
Prove proper operation of fuel oil shut offs. LEGACY COMPONENT DESC: Valve, Control
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2002
Operations/Management
Issued 29 March 2002
Resolved
Reattach the gray water drain to the bulkhead in the engine room from the aft galley.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 4 April 2002
Electrical › Electrical Distribution System (service)
Issued 29 March 2002
Resolved
Remove wire nuts on freash water pumps. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2002
Documentation
Issued 27 April 2000
Resolved
PROVIDE AND POST AN EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Construction/Loadline
Issued 27 April 2000
Resolved
CONDUCT AN OPERATIONAL TEST OF THE INSTALLED BILGE PIPING SYSTEM.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Lifesaving
Issued 27 April 2000
Resolved
CONDUCT REQUIRED DRILLS AS REQUIRED BY ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 20 September 1999
Resolved
MAKE PERMANENT REPAIRS TO FIRE HOSE NOZZEL ON 2ND DECK.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Navigation
Issued 20 September 1999
Resolved
INSTALL PROPER MASTHEAD LIGHT.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Navigation
Issued 20 September 1999
Resolved
POST EMERGENCY BROADCAST PLACARD IN PILOTHOUSE.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Navigation
Issued 20 September 1999
Resolved
IMPLIMENT DECK LOG AND PROVIDE PROOF OF QUARTERLY DRILLS.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Navigation
Issued 20 September 1999
Resolved
PROVIDE CURRENT COPY OF CHART WITH BEST SCALE FOR ENTIRE OPERATING AREA.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Fire Fighting
Issued 20 September 1999
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS INSPECTED.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Navigation
Issued 20 September 1999
Resolved
REPAIR TACHOMETERS ON BOTH MAIN DIESEL ENGINE INDICATORS IN PILOTHOUSE.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Documentation
Issued 20 September 1999
Resolved
MISSING DRUG AND ALCOHOL SUPERVISOR TRAINING CERTIFICATE.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Documentation
Issued 20 September 1999
Resolved
PROVIDE PROOF OF PARTICIPATION IN DRUG AND ALCOHOL PREVENTION PROGRAM OR CONSORTIUM MEMBERSHIP FOR 2ND DECK HAND.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Electrical
Issued 20 September 1999
Resolved
PROPERLY MOUNT GROUNDING DEVICE ON STARBOARD ENGINE/REMOVE ALL DEAD ENDED WIRE IN ENGINE ROOM.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Engineering
Issued 20 September 1999
Resolved
REPLACE BELT GUARDS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Electrical
Issued 14 September 1998
Resolved
PROPERLY SECURE PORT SIDE BATTERY BOX COVER IN ENGINE ROOM.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Electrical
Issued 14 September 1998
Resolved
REPLACE MISSING METER ON GENERATOR OR PROVIDE PROTECTIVE BLANK.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Navigation
Issued 14 September 1998
Resolved
PROVIDE BELT GUARDS FOR BOTH MAIN ENGINES.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Lifesaving
Issued 14 September 1998
Resolved
PROVIDE SUITABLE FUEL TANK VENTS WITH 30x30 MESH SCREEN.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Electrical
Issued 14 September 1998
Resolved
PROPERLY SECURE CABLES WITH HANGERS TO OVERHEAD AFT OF STRB ENGINE.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Accommodation/Occupational Safety
Issued 14 September 1998
Resolved
REPAIR AFT STRB SIDE SAFETY GLASS.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Lifesaving
Issued 14 September 1998
Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR STRB SIDE RING BOUY.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Construction/Loadline
Issued 14 September 1998
Resolved
MAKE SUITABLE REPAIRS TO SCREW HOLE IN HULL IWO STRB AFT RUB RAIL. INSTALLED BOLT WITH SEALANT AS A TEMP REPAIR UNTIL NEW RUB RAIL ARRIVES FROM VENDOR.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Electrical
Issued 14 September 1998
Resolved
REPAIR SWITCH COVER IN LAZERRETE.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Lifesaving
Issued 19 November 1997
Resolved
WATERLIGHT FOR RING BOUY NEEDS 3-6' LANYARD W/DETACHABLE CLIP. DARK SYNTHETIC OR UV RESISTANT LINE.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Lifesaving
Issued 19 November 1997
Resolved
PROVIDE DARK SYNTHETIC OR UV RESISTANT LINES FOR RING BOUYS.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Lifesaving
Issued 19 November 1997
Resolved
POST DONNING INSTRUCTIONS FOR PFD'S.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Electrical
Issued 19 November 1997
Resolved
REMOUNT/SECURE BATTERY BOX ON PORT SIDE.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Electrical
Issued 19 November 1997
Resolved
SECURE A/C JUNCTION BOX COVER IN ENGINE ROOM.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Engineering
Issued 19 November 1997
Resolved
DOUBLE NUT/NYLOCK NUT THROTTLE LINKAGES ON PORT AND STARBOARD ENGINE.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Navigation
Issued 19 November 1997
Resolved
SWING MAG COMPASS FOR CALIBRATION AND PROVIDE DEVIATION CARD.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Lifesaving
Issued 19 November 1997
Resolved
POST PASSENGER CAPACITY FOR UPPER DECK ON LADDERWELLS LEADING TO THE UPPER DECK.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Documentation
Issued 19 November 1997
Resolved
PROVIDE PROOF OF VALID FCC OPERATORS PERMIT._x001C_ _x001C_
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Documentation
Issued 19 November 1997
Resolved
PROVIDE PROOF OF PARTICIPATION IN A DAPI CONSORTIUM.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Navigation
Issued 19 November 1997
Resolved
PROCURE NOTICE TO MARINERS TO UPDATE BRIDGE NAVIGATION CHARTS.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Electrical
Issued 19 November 1997
Resolved
REPAIR OR REPLACE MDE CONTROL BOX FOR STARBOARD ENGINE.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Navigation
Issued 19 November 1997
Resolved
PROCURE 46 CFR AND 47 CFR.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Navigation
Issued 19 November 1997
Resolved
PROVIDE ANCHOR BALL DAYSHAPE.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Navigation
Issued 19 November 1997
Resolved
NEED TO PROVIDE ENTRIES IN SHIPS LOGS FOR CONDUCT OF FIRE/MANOVERBOARD DRILLS AND GARBAGE IAW MARPOL REGS.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Navigation
Issued 5 December 1996
Resolved
PAINT PYRO CONTAINER A BRIGHT COLOR AND MARK WITH VESSEL NAME
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Navigation
Issued 5 December 1996
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Deck/Cargo
Issued 12 October 1995
Resolved
PROVIDE PROOF OF CERTIFICATE OF DOCUMENTATION RENEWAL.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Lifesaving
Issued 12 October 1995
Resolved
PROVIDE 2 RED HAND FLARES.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Navigation
Issued 1 September 1993
Resolved
PROVIDE UPDATED CHARTS FOR VESSELS OPERATING AREA.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Construction/Loadline
Issued 1 September 1993
Resolved
REPLACE PLASTIC THRU HULL FITTINGS WITH METAL FITTINGS AND VALVES FOR ELECTRIC BILGE PUMP OVERBOARD DISCHARGE.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Documentation
Issued 1 September 1993
Resolved
PROVIDE UPDATED CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Documentation
Issued 1 September 1993
Resolved
DO NOT OPERATE WITH CANOPY INSTALLED.
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Documentation
Issued 1 September 1993
Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Lifesaving
Issued 1 September 1993
Resolved
PROVIDE AND POST LIFE PRESERVER DONNING INSTRUCTIONS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993
Documentation
Issued 5 August 1992
Resolved
PROVIDE FCC LICENSE.
Condition: Unknown
Due 5 August 1992
Resolved 5 August 1992
Documentation
Issued 5 August 1992
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 5 August 1992
Resolved 5 August 1992