SO LONG is a 1974 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 1992, most recently in June 1999, along with 9 deficiencies.
Records from 1992 to 1999. Most recent: inspection, 22 June 1999.
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for SO LONG, retrieved 18 September 2026. mauryrecords.com/v/psix-378000.html
Documentation record
Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton 4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
22 June 1999Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 882025
22 December 1993Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 849430
15 November 1993Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1403700
14 September 1993Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 849429
9 September 1993Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1141691
24 November 1992Initial Certification · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1268165
31 May 1992Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460607
PROVIDE WATERLIGHT FOR LIFE FLOAT AND PROPERLY STENCIL.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Fire Fighting
Issued 15 November 1993Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 15 January 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 15 November 1993Resolved
INSTALL NON-COMBUSTIBLE INSULATION IN THE ENGINE ROOM AT THE BOUNDARIES BETWEEN THE ENGINE ROOM AND ACCOMMODATION SPACES.
Condition: Unknown
Due 15 November 1993
Resolved 15 November 1993
Documentation
Issued 15 November 1993Resolved
ARRANGE SIMPLIFIED STABILITY TEST WITH RESIDENT COAST GUARD INSPECTORS.
Condition: Unknown
Due 15 November 1993
Resolved 15 November 1993
Engineering
Issued 15 November 1993Resolved
DOUBLE CLAMP ALL FUEL HOSES
Condition: Unknown
Due 15 November 1993
Resolved 15 November 1993
Lifesaving
Issued 15 November 1993Resolved
REPLACE OUTDATED SIGNAL FLARES
Condition: Unknown
Due 16 November 1993
Resolved 16 November 1993
Documentation
Issued 15 November 1993Resolved
PROCURE RADIO-TELEPHONEY SAFETY CERTIFICATE.
Condition: Unknown
Due 15 January 1994
Resolved 15 January 1994
Documentation
Issued 15 November 1993Resolved
PROVIDE PIPING AND ELECTRICAL DRAWINGS TO RESIDENT COAST GUARD INSPECTORS TO COMPLETE ORIGINAL PACKAGE FOR INITIAL INSPECTION.
Condition: Unknown
Due 15 December 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 24 November 1992Resolved
Provide handle for raw water intake valve.
Condition: Unknown
Due 24 November 1992
Resolved 24 November 1992
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.