Records from 1992 to 2004. Most recent: inspection, 14 October 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 10 August 2004
No resolution recorded
OBTAIN INTERNATIONAL TONNAGE CERTIFICATE.
Action required: 705 - Other - as specified
Due 10 October 2004 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVIDE EVIDENCE THAT CREW IS ENROLLED IN A RANDOM DRUG TEST CONSORTIUM AS PER 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVIDE EVIDENCE OF STCW TRAINING FOR ALL CREW MEMBERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVIDE EVIDENCE THAT ALL CREW MEMBERS HAVE PARTICIPATED IN AN UNDERWAY FIRE, MAN OVERBOARD AND ABANDON SHIP DRILL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVIDE WRITTEN POLICY FOR MONTHLY EPIRB CHECKS AND CONSEQUENCES OF NON-COMPLIANCE AND POST ON BRIDGE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, CONDUCT SATISFACTORY UNDERWAY FIRE, MAN OVERBOARD AND ABANDON SHIP DRILLS WITH CREW AND IN THE PRESENCE OF THE COAST GUARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Not Operational
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF ALL BILGE HIGH WATER ALARMS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF DESIGNATED EMERGENCY LIGHTING FIXTURE IN WHEELHOUSE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF RUDDER INDICATOR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVIDE WRITTEN ANNUAL SERVICING REPORT FOR FIXED CO2 SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF ALL ENGINE ROOM LIGHTING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, RENEW ALL EXHAUST LAGGING, IN ITS ENTIRETY, FOR STARBOARD MAIN ENGINE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, REPAIR EXHAUST LAGGING FOR PORT MAIN ENGINE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, CLEAN ALL ENGIE ROOM BILGES OF OIL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, CLEAN ALL OIL FROM RUDDER ROOMS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, PROPERLY SECURE ALL ELECTRICAL WIRING FROM PORT MAIN ENGINE FOUND DRAPING OVER ITS EHAUST MANIFOLD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 August 2004
No resolution recorded
PRIOR TO CARRYING PASSENGERS, INSTALL COMPLETE HAILING PORT ON VESSEL STERN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service)
Issued 26 February 2004
Resolved
Prior to carrying passengers. Stbd gear room forward of engine room, electrical box cover needs to be reinstalled and wires properly routed. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2004
Resolved 23 March 2004
Resolution: Cover reinstalled and wires properly routed.
Deck/Cargo › Holds/Tanks
Issued 26 February 2004
Resolved
Prior to carrying passengers. Port fuel tank leaking small amount of fuel. Repair fuel tank. LEGACY COMPONENT DESC: Independent Tank
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2004
Resolved 23 March 2004
Resolution: Fuel tank repaired.
Construction/Loadline › Penetrations
Issued 26 February 2004
Resolved
Stbd exhaust flange pitted needs to be replaced. LEGACY COMPONENT DESC: Pipe Flange
Condition: Unknown
Due 11 March 2004
Resolved 23 March 2004
Resolution: Flange renewed.
Construction/Loadline › Penetrations
Issued 26 February 2004
Resolved
Pipe flange in way of port bow from sink in cabin wasted and needs repaired. LEGACY COMPONENT DESC: Pipe Flange
Condition: Unknown
Due 11 March 2004
Resolved 23 March 2004
Resolution: Flange renewed.
Construction/Loadline › Structures
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROPERLY SEAL DECK AREA IN WAY OF REMOVED BOARDING RAMP LEGACY COMPONENT DESC: Deck Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Area welded IWO removed baording ramp.
Pollution Prevention/Response › Prevention Equipment
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, MAKE FOREPEAK BILGE PUMP OPERABLE LEGACY COMPONENT DESC: Oily Mixture Discharge Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Bilge pump made operational.
Construction/Loadline › Structures
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, MAKE PORT COLLISION BULKHEAD WATERTIGHT LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Bulkhead made watertight.
Electrical › Electric Supply System (service)
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, SECURE BATTERY BOX AND BATTERY CHARGER WIRING IN PORT FOREPEAK. LEGACY COMPONENT DESC: Battery Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Box and wiring made secure.
Construction/Loadline › Hull
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REPAIR DAMAMGE TO PORT AND STBD TRANSOM CORNERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Transom corners renewed.
Construction/Loadline › Structures
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, RENEW FRACTURED DECK PLATING PORT AFT DECK AS DESIGNATED BY THE ATTENDING CG MARINE INSPECTOR. LEGACY COMPONENT DESC: Deck Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Deck plating renewed.
Stability
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REMOVE ADDITIONAL GENERATOR. ANY ALTERATIONS TO VESSEL'S EXISTING EQUIPMENT MUST BE APPROVED PRIOR TO INSTALLATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Operations/Management
Issued 12 February 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, COMPLETE A CREDITED DRYDOCK/HULL EXAM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 23 March 2004
Resolution: Credit Dry-dock exam completed.
Operations/Management › Drug and Alcohol Testing
Issued 28 July 2003
Resolved
Provide proof FROM WPCI of enrollment in a drug testing program. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Received letter from WPCI of enrollment.
Operations/Management › Vessel Safety Management
Issued 28 July 2003
Resolved
Provide proof of annual internal company audit. LEGACY COMPONENT DESC: Reports and Analysis
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Reviewed company''s internal audit paperwork.
Personnel › Certificates/Documents/Licenses
Issued 28 July 2003
Resolved
Provide proof of crew's first aid training and CPR. LEGACY COMPONENT DESC: STCW Certificate, Medical First Aid/Care
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Crew provided STCW endorsements.
Lifesaving › Buoyant Apparatus
Issued 28 July 2003
Resolved
Make serviceable or replace 22 person life float.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 3 October 2003
Resolution: Life float replaced in kind.
Lifesaving › Buoyant Apparatus
Issued 28 July 2003
Resolved
Provide 5 serviceable paddles for the life floats. LEGACY COMPONENT DESC: Paddles
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Serviceable paddles placed on-board.
Lifesaving › Buoyant Apparatus
Issued 28 July 2003
Resolved
Paint with black paint the name of vessel on life floats. LEGACY COMPONENT DESC: Vessel Name
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Name properly stenciled on appliances.
Lifesaving › Lifebuoys
Issued 28 July 2003
Resolved
Port ring buoy life line needs to be replaced. Ring buoy also needs reflective tape LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Ring buoys made seviceable.
Lifesaving › Lifebuoys
Issued 28 July 2003
Resolved
Stbd ring buoy needs to have grab line replaced. Ring buoy also needs reflective tape. LEGACY COMPONENT DESC: Grab line
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Ring buoy made serviceable.
Communications › Radio Communications
Issued 28 July 2003
Resolved
Provide proof of EPIRB registration. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: EPIRB registation sticker placed on EPIRB.
Accommodation/Occupational Safety › Occupational Safety
Issued 28 July 2003
Resolved
Stbd hand rail on pilot house needs to be made secure. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 4 August 2003
Resolved 7 August 2003
Resolution: Hand rail bolted to pilot house.
Electrical › Electrical Distribution System (service)
Issued 28 July 2003
Resolved
Junction box in engine room needs to have the cover replaced. LEGACY COMPONENT DESC: Junction Box
Condition: Damaged By Earlier Event
Due 28 July 2003
Resolved 7 August 2003
Resolution: Junction box removed.
Electrical › Lighting (service)
Issued 28 July 2003
Resolved
Lights in reduction gear rooms needs to operate properly. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 4 August 2003
Resolved 7 August 2003
Resolution: Lights operate properly.
Engineering › Lubricating Oil Service System
Issued 28 July 2003
Resolved
Remove old unused piping in engine room. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Due 4 August 2003
Resolved 7 August 2003
Resolution: Unused piping removed.
Engineering › Steering Gear System
Issued 28 July 2003
Resolved
Steering pump has numerous leaks at pump and splitter valve. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: New splitter valve installed and leaks corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 28 July 2003
Resolved
Remove toilet water pump wires that are hanging loose in engine room. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Due 4 August 2003
Resolved 7 August 2003
Resolution: Wires removed.
Fire Fighting › Fire Hoses
Issued 28 July 2003
Resolved
Label engine room fire hose storage container. LEGACY COMPONENT DESC: Storage container
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Container properly labeled.
Electrical › Lighting (service)
Issued 28 July 2003
Resolved
Replace or make properly serviceable the light fixture over passenger entrance on port aft side. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Light properly attached and serviceable.
Communications › Radio Communications
Issued 28 July 2003
Resolved
Radio transformer needs to be relocated due to probability of water leakage from foward port fire hose. LEGACY COMPONENT DESC: VHF Radiotelephone
Condition: Improper Installation
Due 28 August 2003
Resolved 7 August 2003
Resolution: Transformer relocated to bridge.
Electrical › Lighting (emergency)
Issued 28 July 2003
Resolved
STBD emergency exit light missing. Install new fixture. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: New fixture installed.
Fire Fighting › Fixed Fire Detection System
Issued 28 July 2003
Resolved
Provide proof of testing of heat detectors in engine room. LEGACY COMPONENT DESC: Heat Detectors
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 3 October 2003
Resolution: Provided proof of heat detector testing.
Construction/Loadline › Structures
Issued 28 July 2003
Resolved
Install door alarms on hatches entering reduction gear rooms. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Unknown
Due 28 August 2003
Resolved 3 October 2003
Resolution: Alarms installed and tested, all sat.
Pollution Prevention/Response › Prevention Equipment
Issued 28 July 2003
Resolved
Demonstrate proper operation of high bilge alarms. LEGACY COMPONENT DESC: Bilge Monitor
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: High bilge alarms tested satisfactory.
Engineering › Fuel Oil Service System
Issued 28 July 2003
Resolved
Demonstrate proper operation of port emergency shut off valve. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2003
Resolved 7 August 2003
Resolution: Port emergency shut off valve operated properly.
Fire Fighting › Emergency Fire Pumps
Issued 28 July 2003
Resolved
Prove proper operation of emergency fire pump. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Due 21 August 2003
Resolved 3 October 2003
Resolution: Emergency fire pump tested, all sat.
Construction/Loadline › Hull › Side Shell
Issued 4 February 2003
Resolved
REMOVE PORT EXHAUST SOFT PATCH AND RENEW METAL UNDERNEATH AS REQUIRED
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Construction/Loadline › Hull › Side Shell
Issued 4 February 2003
Resolved
RENEW METAL UNDER STBD RUBRAIL AS MARKED BY CG INSPECTOR
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Construction/Loadline › Hull › Side Shell
Issued 4 February 2003
Resolved
REPAIR PIT UNDER STBD DRAFT MARK
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 February 2003
Resolved
REMOVE SLUICE VALVE STBD VOID #1 AND FIT INSERT
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Construction/Loadline › Hull › Transverse Frame
Issued 4 February 2003
Resolved
REPAIR CRACKED TRANSVERSE FRAME IN VOID #2
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 February 2003
Resolved
ENSURE ALL WIRES ARE SEALED THROUGH WATERTIGHT BULKHEADS
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 4 February 2003
Resolved
REMOVE OIL AND SLUDGE FROM ENGINE ROOM, REDUCTION GEAR ROOMS, AND RUDDER ROOM
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2003
Resolved
REPAIR HOLES INBOARD OF STBD AFT ENGINE ROOM VENT
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2003
Resolved 25 February 2003
Fire Fighting › Nozzles
Issued 17 July 2002
Resolved
PROVIDE PROPER FIRE NOZZLE FOR ENGINE ROOM FIRE HOSE LEGACY COMPONENT DESC: Type
Due 17 August 2002
Resolved 25 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 July 2002
Resolved
RENEW ROPES FOR THE LADDERS AT ALL FOUR ACCOMODATION STATIONS
Due 17 August 2002
Resolved 25 February 2003
Construction/Loadline › Structures
Issued 17 July 2002
Resolved
RENEW THREE WINDOWS IN PILOTHOUSE THAT ARE OBSCURED BY HAIRLINE FRACTURES LEGACY COMPONENT DESC: Superstructure
Due 17 August 2002
Resolved 25 February 2003
Documentation › Logs/Records › Logbook (official)
Issued 17 July 2001
Resolved
PROVIDE LOGBOOK TO RECORD ALL VESSEL OPERATIONS AND PASSENGER COUNTS
Due 17 July 2001
Resolved 17 July 2001
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 17 July 2001
Resolved
PROVIDE EMERGENCY INSTRUCTIONS IN PILOTHOUSE
Due 17 July 2001
Resolved 17 July 2001
Navigation › Piloting/Steering › Marine Charts
Issued 17 July 2001
Resolved
PROVIDE CHARTS AND NAVIGATION PUBLICATIONS IAW 46 CFR 184.420
Due 17 July 2001
Resolved 17 July 2001
Navigation › Collision/Grounding Avoidance
Issued 17 July 2001
Resolved
PROVIDE OPERATIONAL HORN
Due 17 July 2001
Resolved 17 July 2001
Accommodation/Occupational Safety
Issued 17 July 2001
Resolved
PROVIDE OPERATIONAL PUBLIC ADDRESS SYSTEM
Due 17 July 2001
Resolved 17 July 2001
Construction/Loadline › Structures › Ventilators
Issued 17 July 2001
Resolved
PROVIDE POWERED ENGINE ROOM FANS WITH AUTOMATIC SHUT-OFF IAW 46 CFR 181.410(b)(10)
Due 17 July 2001
Resolved 17 July 2001
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 July 2001
Resolved
SERVICE FIXED FIRE EXTINGUISHING SYSTEM IAW NFPA STANDARDS
Due 17 July 2001
Resolved 17 July 2001
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 July 2001
Resolved
INSTALL ALL PORTABLE FIRE EXTINGUISHERS IN APPROVED BRACKETS
Due 17 July 2001
Resolved 17 July 2001
Engineering › Diesel Engine (auxiliary)
Issued 17 July 2001
Resolved
RENEW SEA WATER DISCHARGE HOSE FOR ELECTRICAL GENERATOR ENGINE
Due 17 July 2001
Resolved 17 July 2001
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2001
Resolved
REPAIR/RENEW ALL LIFEJACKETS AS IDENTIFIED BY CG INSPECTOR
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Buoyant Apparatus
Issued 31 May 2001
Resolved
INSTALL PAINTERS FOR LIFEFLOATS
Due 31 May 2001
Resolved 17 July 2001
Navigation › Piloting/Steering
Issued 31 May 2001
Resolved
PROVIDE VESSEL WITH BELL WITH MOUTH OF AT LEAST 8"
Due 31 May 2001
Resolved 17 July 2001
Documentation › Logs/Records › Logbook (official)
Issued 31 May 2001
Resolved
PROVIDE VESSEL WITH LOGBOOK TO RECORD VESSEL TRAINING
Due 31 May 2001
Resolved 17 July 2001
Documentation › Logs/Records › Logbook (official)
Issued 31 May 2001
Resolved
PROVIDE A PRE-UNDERWAY CHECKLIST IAW SMS
Due 31 May 2001
Resolved 17 July 2001
Documentation › Logs/Records › Logbook (official)
Issued 31 May 2001
Resolved
PROVIDE A LOGBOOK TO RECORD ALL MAINTENANCE TO FIREFIGHTING AND LIFESAVING EQUIPMENT
Due 31 May 2001
Resolved 17 July 2001
Deck/Cargo › Mooring/Anchoring
Issued 31 May 2001
Resolved
PROVIDE MECHANISM TO SAFELY DISENGAGE ANCHOR DRUM LEGACY COMPONENT DESC: Brake
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 31 May 2001
Resolved
REMOVE ALL INOPERATIVE LIFERAFTS FROM THE VESSEL
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 May 2001
Resolved
LABEL CHILDREN'S LIFEJACKET STORAGE CLEARLY WITH AMOUNT AND LOCATION. REMOVE ALL OTHER NON-APPLICABLE SIGNS THROUGHOUT VESSEL
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Lifebuoys
Issued 31 May 2001
Resolved
RENEW AFT DECK LIFERING. PROVIDE 1 LIFERING WITH LIGHT AND 60' PAINTER. ALL LIFERINGS TO HAVE RETRO-REFLECTIVE TAPE AND VESSEL'S NAME
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Buoyant Apparatus
Issued 31 May 2001
Resolved
INSTALL WEAK LINK PAINTERS SO ATTACHMENT POINTS ARE SPLICED AND FITTED UNDER THE PAINTER CANISTER
Due 31 May 2001
Resolved 17 July 2001
Construction/Loadline › Structures › Ventilators
Issued 31 May 2001
Resolved
PROVIDE METHOD TO COVER ENGINE ROOM AIR INTAKES
Due 31 May 2001
Resolved 17 July 2001
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 31 May 2001
Resolved
PROVIDE FIRE DETECTION SYSTEM IN MACHINERY SPACES IAW 46 CFR 181.400(c)
Due 31 May 2001
Resolved 17 July 2001
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 May 2001
Resolved
PROVIDE STEP BY STEP INSTRUCTIONS FOR THE DISCHARGE OF THE CO2 SYSTEM AT THE DISCHARGE STATION IAW 46 CFR 185.612(a)
Due 31 May 2001
Resolved 17 July 2001
Communications › Radio Communications › EPIRB
Issued 31 May 2001
Resolved
REMOVE INACTIVE EPIRB FROM PILOTHOUSE
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Hand Flares › Condition
Issued 31 May 2001
Resolved
REMOVE EXOIRED PYROTECHNICS FROM PILOTHOUSE
Due 31 May 2001
Resolved 17 July 2001
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 31 May 2001
Resolved
INSTALL REQUIRED HIGH BILGE LEVEL ALRMS REQUIRED BY 46 CFR 182.530
Due 31 May 2001
Resolved 17 July 2001
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 31 May 2001
Resolved
CLEARLY MARK ALL ESCAPE ROUTES FOR PASSENGERS IN CABIN AREA. REMOVE ALL OLD FOREIGN LANGUAGE PLACARDS THAT NO LONGER APPLY
Due 31 May 2001
Resolved 17 July 2001
Pollution Prevention/Response › Prevention Equipment
Issued 31 May 2001
Resolved
INSTALL MARPOL V GARBAGE DISCHARGE PLACARD
Due 31 May 2001
Resolved 17 July 2001
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 May 2001
Resolved
PROVIDE 2 PORTABLE LIGHTS, 1 AT THE PILOTHOUSE AND 1 AT THE ENTRANCE TO THE MACHINERY ROOM
Due 31 May 2001
Resolved 17 July 2001
Construction/Loadline › Penetrations
Issued 31 May 2001
Resolved
PROVIDE HANDWHEEL FOR ELECTRICAL GENERATOR SEA SUCTION VALVE
Due 31 May 2001
Resolved 17 July 2001
Fire Fighting › Fire Pumps › Pressure
Issued 31 May 2001
Resolved
INSTALL PRESSURE GAUGES FOR EACH FIRE PUMP
Due 31 May 2001
Resolved 17 July 2001
Fire Fighting › Fire Pumps › Arrangement
Issued 31 May 2001
Resolved
PROVIDE PUMP DATA FOR EACH FIRE AND BILGE PUMP
Due 31 May 2001
Resolved 17 July 2001
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 31 May 2001
Resolved
MAKE BILGE PUMPING SYSTEM OPERABLE
Due 31 May 2001
Resolved 17 July 2001
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 31 May 2001
Resolved
LABEL BILGE SUCTION MANIFOLD VALVES IN EACH HULL
Due 31 May 2001
Resolved 17 July 2001
Construction/Loadline › Penetrations
Issued 31 May 2001
Resolved
PROPERLY SECURE ALL VOID COVERS
Due 31 May 2001
Resolved 17 July 2001
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 31 May 2001
Resolved
REMOVE OR PERMANENTLY INSTALL OIL PRESSURE GAUGE UNDER BRIDGE CONSOLE
Due 31 May 2001
Resolved 17 July 2001
Lifesaving › Buoyant Apparatus
Issued 31 May 2001
Resolved
RENEW RETRO-REFLECTIVE TAPE ON PORT AFT LIFEFLOAT AND PATCH TEARS WITH APPROVED KIT
Due 31 May 2001
Resolved 17 July 2001
Engineering › Fuel Oil Service System › Filter
Issued 31 May 2001
Resolved
INSTALL HEAT SHIELDS ON RACOR FUEL FILTERS FOR STBD PROPULSION ENGINE
Due 31 May 2001
Resolved 17 July 2001
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 31 May 2001
Resolved
REPAIR EXHAUST LEAK ON THE EMERGENCY FIRE PUMP
Due 31 May 2001
Resolved 17 July 2001
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 31 May 2001
Resolved
PROVIDE MEANS TO LOCK SEWAGE OVERBOARD DISCHARGE VALVES CLOSED
Due 31 May 2001
Resolved 17 July 2001
Documentation
Issued 29 July 1992
Resolved
Provide Passenger Ship Safety Exemption Certificate from classification Society listing all exemptions permitted._x001C_
Condition: Unknown
Due 29 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 July 1992
Resolved
Properly install liferafts with weak link and hydrostatic releases.
Condition: Unknown
Due 5 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 July 1992
Resolved
Properly secure embarkation ladder to deck on starboard side, aft.
Condition: Unknown
Due 5 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 29 July 1992
Resolved
Provide oil discharge placard at bilge manifold in engine room.
Condition: Unknown
Due 5 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 July 1992
Resolved
Conduct a satisfactory fire drill, man overboard drill, and abandon ship drill to the satisfaction of a Coast Guard Marine Inspector.
Condition: Unknown
Due 12 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 29 July 1992
Resolved
Properly wire refrigerator in main passenger compartment OR remove all unused wiring.
Condition: Unknown
Due 5 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 July 1992
Resolved
Provide charts and publications for St. Thomas, St. John area of operation.
Condition: Unknown
Due 5 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 29 July 1992
Resolved
Label all emergency lights with a red "E" where missing.
Condition: Unknown
Due 5 August 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past