MAURY USCG vessel records Sign in
← All vessels

LI

LI is a 1992 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1992, most recently in December 2024, along with 29 deficiencies.

Records from 1992 to 2024. Most recent: inspection, 2 December 2024.

Built
1992
Last inspected
2 December 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH5048
378366
Flag
UNITED STATES
—
Maury page id
psix-378366

Inspections, by type

…with no type recorded3
Years with a record 29 calendar years (1992–2024)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

2 December 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8042018
20 September 2023 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7791276
25 May 2023 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7689691
17 October 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7578689
4 November 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7336883
30 August 2021 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7281616
23 September 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7062988
24 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6861929
22 October 2019 Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6839555
9 April 2019 Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6658848
23 April 2018 Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6397609
6 March 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6100114
27 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5920931
1 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5845168
5 June 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4880290
21 May 2014 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4864219
11 March 2014 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4814139
8 June 2012 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4337448
8 March 2010 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3691658
19 May 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3211025
21 March 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3170329
3 July 2007 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2981897
13 April 2006 Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2623737
2 May 2005 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2347192
16 April 2004 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2045118
26 February 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2013384
7 May 2003 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1790092
29 May 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1664283
15 March 2002 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1494017
30 May 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1366382
4 May 2000 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 819384
3 May 2000 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1444324
9 March 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1452637
9 July 1999 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1404800
17 August 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130767
17 July 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1115780
1 July 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1115920
25 July 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1090220
25 April 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1183983
29 March 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 835299
27 April 1994 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1359885
3 May 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1370605
21 April 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1370606
27 October 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 955423
1 September 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 958628
29 June 1992 Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 950132

Deficiency record · 29

Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 June 2016 Resolved
Provide water light for life ring, no light onboard, corrected on the spot, 46CFR180.70.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 27 June 2016
Resolution: corrected on the sport
Lifesaving › Lifebuoys › Serviceable
Issued 27 June 2016 Resolved
Provide 60” of line for life ring, only 30’ onboard, corrected on the spot 46CFR180.70.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 27 June 2016
Resolution: corrected on the spot.
Fire Fighting › Fire Bucket › Availability
Issued 27 June 2016 Resolved
Provide 3 fire buckets none onboard, corrected on the spot, rep stated they get used in the winter for spreading salt and must have forgot to put them back on, corrected on the spot, 46CFR181.610.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 27 June 2016
Resolution: corrected on thespot.
Engineering › Bilge Water Management System › Pump
Issued 27 June 2016 Resolved
Provide portable hand bilge pump not onboard, corrected on the spot, 46CFR182.520.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 27 June 2016
Resolution: corrected on the spot.
Engineering › Fuel Oil Service System › Hose
Issued 27 June 2016 Resolved
Make fuel hose onboard J-1942 with fittings by 11JUL16, 46CFR182.720.
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 22 July 2016
Resolution: Supply piping was replaced with copper tubing and a short section of < 30” was connected leading to the fuel filter.
Electrical › Lighting (service) › Outlet Box
Issued 27 June 2016 Resolved
Enclose or remove open exposed wiring for lighting cabin overhead by 11JUL16, 46CFR183.340.
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 22 July 2016
Resolution: New overhead lighting was installed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 July 2007 Resolved
repair shutdown and over ride system to manufacturers specs.
Due 17 July 2007
Resolved 17 July 2007
Resolution: Repaired sat.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 July 2007 Resolved
replace racor filter flame screen.
Due 17 July 2007
Resolved 17 July 2007
Resolution: Racor filter bowl repalced sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 3 July 2007 Resolved
main diesel engine is smoking looks to be burning oil.
Due 17 July 2007
Resolved 17 July 2007
Resolution: Engine replaced in kind.
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 March 2006 Resolved
Properly mount inverter supply
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Electrical › Electrical Distribution System (service) › Busway
Issued 23 March 2006 Resolved
Properly mount bus heater.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2006 Resolved
Repair gunwale located on the foward port side and tighten rubber rub rail.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2006 Resolved
Repair gel coat damage to side shell located on the aft starboard side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Engineering › Fuel Oil Service System › Vent Pipe
Issued 23 March 2006 Resolved
Install flame screen for fuel tank vent pipe.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Communications › Alarms/Indicators
Issued 16 April 2004 Resolved
Install Hi-level alarm with audible and visual indicators. Until installed visually inspect bilge every 30 minutes while in operation. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 29 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 April 2004 Resolved
Provide updated First aid kit LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 29 April 2004
Communications › Audible Communications
Issued 16 April 2004 Resolved
Provide sound signal. LEGACY COMPONENT DESC: Horn/Whistle
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 29 April 2004
Construction/Loadline › Markings
Issued 16 April 2004 Resolved
Correct Hailing port. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 29 April 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 May 2003 Resolved
Install proper halyard and clip on waterlight for ring buoy.
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 28 May 2003
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2003 Resolved
Install radio emergency broadcast placard.
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 28 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 29 May 2002 Resolved
Provide life jacket donning placard
Due 10 June 2002
Resolved 31 May 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 May 2002 Resolved
provide fuel oil shut-off at the engine end of the fuel line. LEGACY COMPONENT DESC: Valve
Due 10 June 2002
Resolved 31 May 2002
Engineering › Shafting/Propeller Arrangements
Issued 29 May 2002 Resolved
Replace the rubber boot for the shaft. LEGACY COMPONENT DESC: Propeller Shaft
Due 10 June 2002
Resolved 31 May 2002
Engineering › Steering Gear System
Issued 29 May 2002 Resolved
Replace the rudder post plate and tighten the packing gland. LEGACY COMPONENT DESC: Rudder
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2002
Engineering
Issued 1 September 1992 Resolved
PROVIDE METALIC SHIELD FOR VESSEL'S PLASTIC FUEL FILTER.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Engineering
Issued 1 September 1992 Resolved
INSTALL PROPER FUEL LINE CONNECTIONS FOR LINES TO THE MAIN ENGINE.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Engineering
Issued 1 September 1992 Resolved
INSULATE UNLAGGED SECTION OF MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Fire Fighting
Issued 1 September 1992 Resolved
INSTALL A LIGHT ON STEERING STATION INDICATING ACTIVATION OF FIXED HALON _x001C_ EXTINGUISHING SYSTEM FOR THE ENGINE SPACE.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Accommodation/Occupational Safety
Issued 1 September 1992 Resolved
INSTALL TWO VENTS FOR MACHINERY SPACE WITH ONE OF THE VENT DUCT EXTENDING TO THE LOWER SECTION OF BILGE.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.