← All vessels
FRANK B
FRANK B is a 1992 tank barge. The Coast Guard has recorded 39 inspections since 1992, most recently in August 2022, along with 33 deficiencies and 1 operational control.
Records from 1992 to 2022. Most recent: inspection, 3 August 2022.
- Built
- 1992
- Last inspected
- 3 August 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 33 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
79 - Regulatory (Subpart C or D), Net Ton
79 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
3 August 2022
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7530857
2 March 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7411088
27 May 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7201234
28 January 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7132677
26 February 2020
MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6921505
27 February 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6630844
21 February 2018
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359014
8 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6101046
20 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5881960
31 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5844352
4 May 2015
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5117264
19 May 2014
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4848485
14 March 2012
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4230160
25 February 2011
VRP Review
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3952630
9 February 2011
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3939539
12 June 2010
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3748541
4 June 2009
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3474286
3 June 2008
MTSA Verification · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3220283
6 June 2007
Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2946494
6 June 2006
Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2666309
11 May 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2646336
10 May 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2645833
17 April 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2634839
6 October 2005
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2509125
14 June 2005
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2375825
13 October 2004
Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2086283
19 June 2003
Periodic Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1840798
28 May 2002
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1626233
4 June 2001
Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362276
19 July 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427873
14 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388861
16 June 1998
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386299
11 April 1997
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1460951
7 August 1996
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1437136
8 March 1996
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388042
10 March 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355154
8 March 1994
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1164736
17 March 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1150163
14 September 1992
Initial Certification · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 950164
Deficiency record · 33
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 May 2021
Resolved
There is a gap between the flame screen bowl and the flange on the pressure relief valve which is mounted next to the PV valve on the tank dome. The gap is not vapor-tight and essentially bypasses the flame screen and leaves the tanks in an open-vented configuration at all times. Add a gasket or otherwise modify the configuration in order to make the pressure relief valve vapor-tight.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 27 May 2021
Resolved
Provide documentation showing that the cargo tank gauging connectors which are fitted within the hazardous area are intrinsically safe.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 February 2020
Resolved
Port Nav light was in-op.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2019
Resolved
Re-establish benzene monitoring program and follow safety procedures prior to next loading.
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 27 February 2019
Resolved
Prove wiring to gauging system is intrinsically safe or explosion proof.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 27 February 2018
Resolved
Install approved intrinsically safe, explosionproof, or purged and pressurized electrical equipment (switches, fuses, battery boxes, lights, chargers) and through runs of marine shipboard cable in accordance with 46CFR111.105.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 May 2014
Resolved
Porve proper operation of navigation lights and red warning light. Vessel restricted to daylight operations only.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 21 May 2014
Resolved
Provide current hose hydrostatic test results.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 21 May 2014
Resolved
Make proper repairs to battery boxes.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 June 2010
Resolved
Replace #1 and #2 Cargo Tank Fuel Sensors.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 12 June 2010
Resolved
Properly secure cargo tank siphoning piping and replace fitting.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 12 June 2010
Resolved
Replace cargo pump actuators for cargo pumps #1, 2 and 3.
Deck/Cargo › Towing › Towline
Issued 3 June 2008
Resolved
Repair/renew twisted port aft tow cable.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 3 June 2008
Resolved
Replace non-authorized secondary PV valve hinge pin with proper pin and clips.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 June 2008
Resolved
Place updated (most recent) V.R.P. on barge.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 June 2008
Resolved
Secure extra portable fire extinguisher.
Deck/Cargo › Holds/Tanks › Ullage
Issued 6 June 2006
Resolved
Repair one pin on #1 fuel cell ullage cover & provide snap ring clips where missing on ullage vents.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2006
Resolved
Prove proper operation of starboard running light.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 6 June 2006
Resolved
Repair sensor to #2 fuel cell.
Deck/Cargo › Towing › Terminal Gear
Issued 6 June 2006
Resolved
Provide evidence of towing/terminal gear (wire) maintenance.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 22 June 2005
Resolved
Develop and implement transfer procedures and maintain copy on board iaw 33 CFR 155.750
Documentation › Markings/Placards › Oil Discharge Placard
Issued 22 June 2005
Resolved
Provide discharge placard iaw 33 CFR 155.450
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 14 June 2005
Resolved
Mark P/S bow with vessel name iaw 46 CFR 67.123
Deck/Cargo › Holds/Tanks › Ullage
Issued 13 October 2004
Resolved
Replace gaskets in way of ullage opening PV vents IAW vent design specifications. 46 CFR 32.20-5
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 19 June 2003
Resolved
Renew gaskets in way of ullage covers pressure vacuum valves on all three tanks. LEGACY COMPONENT DESC: Pressure/Vacuum Relief Valve
Electrical › Electrical Distribution System (service)
Issued 19 June 2003
Resolved
Provide bonding cable of sufficient length to reach transfer manifold ground connection. LEGACY COMPONENT DESC: Grounding Conductor
Electrical › Electrical Distribution System (service)
Issued 19 June 2003
Resolved
Provide proper size cable in way of cargo tank #1 umbilical cord. LEGACY COMPONENT DESC: Cable
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 28 May 2002
Resolved
Repair connections to dock to prevent chafing on barge. LEGACY COMPONENT DESC: Piping
Deck/Cargo
Issued 4 June 2001
Resolved
Provide documentation of annual review by 07JUL01 to the satisfaction of the attending Marine Inspector.
Deck/Cargo
Issued 11 April 1997
Resolved
Clean or renew vent flame screen for the aft two tanks._x001C_
Documentation
Issued 17 March 1993
Resolved
PROVIDE A CREW PROTECTION PROGRAM FROM THE HAZARDS OF BENZENE AS REQUIRED BY 46 CFR 197. THE PROGRAM IS REQUIRED UNLESS LABORATORY RESULTS OF CARGO SAMPLES CONSISTENTLY SHOW LESS THAN 0.5 PERCENT BENZENE BY VOLUME. NVIC 6-92 MAY BE OF HELP IN COMPLYING (ORDER FROM G-MSC, [phone withheld]).
Documentation
Issued 17 March 1993
Resolved
PROVIDE COPY OF APPROVED VESSEL RESPONSE PLAN AS PER NVIC 8-92 NOT LATER THAN 13 AUG 93. PLAN MUST BE APPROVED BY USCG COMMANDANT (G-MEP-6) IN WASHINGTON DC.
Unknown
Issued 14 September 1992
Resolved
INSTALL DRAFT MARKS TO BE IN COMPLIANCE WITH 46 CFR 32.05-1, INCLUDING HAVING THE BOTTOM OF THE VESSEL SERVE AS THE STARTING (ZERO) POINT. (MARKSNEED TO BE PAINTED ONLY OVER THE RANGE OF OPERATING DRAFTS.)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.