MAURY USCG vessel records Sign in
← All vessels

METEOR

METEOR is a 1966 freight ship. The Coast Guard has recorded 116 inspections since 1982, most recently in July 2015, along with 250 deficiencies and 1 casualty investigation in 2005.

Records from 1982 to 2015. Most recent: inspection, 28 July 2015.

Built
1966
Last inspected
28 July 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8450677 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
378461
Flag
UNITED STATES
366657000 (licence lapsed)
Maury page id
psix-378461

Inspections, by type

…with no type recorded36
Years with a record 25 calendar years (1982–2015)
The 116 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12326 - Dead Weight, Ton
16658 - Convention (Subpart B), Gross Ton
5103 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KXEKMMSI 366657000 · expired · compulsorily equipped · granted 28 January 1993, cancelled 28 January 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 116

28 July 2015 Hull Examination · Load Line/Change of Employment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5187404
5 February 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2867366
7 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2738708
20 June 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2686155
8 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2598984
7 March 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2597744
22 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2589819
14 February 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2585060
11 January 2006 In-Service Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2564902
19 October 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2517834
19 July 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2409048
19 May 2005 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2315980
19 May 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2384564
28 September 2004 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2207174
26 July 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2145444
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087512
19 May 2004 Periodic Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2071967
4 March 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2018139
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996251
17 December 2003 In-Service Inspection · Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1962085
28 July 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1859895
6 June 2003 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1820270
2 April 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1770939
14 February 2003 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1744702
12 December 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1720716
21 December 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1477660
5 December 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076516
20 November 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772550
22 October 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1366610
5 October 2001 Internal Structural Exam · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1460574
9 February 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1058818
25 April 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1049323
21 September 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1338425
1 April 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1434843
25 June 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1415014
16 June 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 791775
18 March 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 778013
12 March 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 773995
4 March 1998 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378294
21 January 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1450123
23 June 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1112692
9 May 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378041
1 May 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 39050
16 April 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093551
24 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1095876
3 October 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156933
18 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658399
30 August 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212574
30 August 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 226967
27 August 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1380632
7 August 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 876927
12 June 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1467486
7 June 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 158732
25 January 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 882660
27 July 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 17828
11 July 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 157895
16 May 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1419398
27 March 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828588
14 March 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874970
6 March 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 857500
2 November 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1174531
24 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 7713
11 October 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 853019
25 August 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866170
2 June 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870247
2 June 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012270
3 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658382
4 April 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658383
31 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 683391
28 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 31072
24 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165977
17 February 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 132731
11 February 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 853018
10 December 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159938
7 December 1993 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1438137
21 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 86589
19 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839021
13 October 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1158569
6 August 1993 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155157
23 July 1993 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154945
11 March 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1358016
5 February 1993 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136632
3 February 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1134520
7 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 830644
17 December 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 163466
25 November 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451826
24 November 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1135343
16 November 1992 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 961592
1 October 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1268868
5 March 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 962115
5 March 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1257642
31 July 1991 Hull Examination · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 934234
31 July 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 962118
26 May 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249442
24 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935642
16 May 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236220
25 April 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262749
18 April 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935149
1 April 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926177
20 February 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236440
16 January 1991 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 908732
26 November 1990 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1240793
24 August 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1234233
14 February 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229260
19 December 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1211017
24 October 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1203580
4 August 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1038227
28 October 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1333356
1 October 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1318667
16 December 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1339114
1 October 1985 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 989461
20 September 1985 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 986181
13 August 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1293366
2 August 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 986093
15 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 980193
12 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966589

Deficiency record · 250

Lifesaving › Launching Appliances › Falls
Issued 11 January 2006 Resolved
Replace falls and test davits prior to sailing.
Action required: 705 - Other - as specified
Resolved 21 February 2018
Resolution: Deficiency closed, vessel scrapped in 2015
Fire Fighting › Structural - B Class Divisions › Doors
Issued 19 May 2005 Resolved
Prove proper operation of FSD 01-132-2.
Due 29 July 2005
Resolved 19 July 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2005 Resolved
Replace cracked fluorescent light cover located outside the entrance to 1-121-3.
Due 29 July 2005
Resolved 19 July 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 May 2005 Resolved
Cap battery cables on ROS alarm.
Due 29 July 2005
Resolved 19 July 2005
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2005 Resolved
Repair corroded floor in 1-124-2.
Due 29 July 2005
Resolved 19 July 2005
Documentation › Logs/Records › Logbook (official)
Issued 19 May 2005 Resolved
Provide current up to date lifesaving equipment maintenance record log.
Due 29 July 2005
Resolved 19 July 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 19 May 2005 Resolved
Provide proper cover for water fountain located across from 1-119-2.
Due 29 July 2005
Resolved 19 July 2005
Fire Fighting › Structural - B Class Divisions › Doors
Issued 19 May 2005 Resolved
Repair and prove proper operation of door to the port boatdeck.
Due 29 July 2005
Resolved 19 July 2005
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 19 May 2005 Resolved
Replace expired and non serviceable rations for the lifeboats prior to activation.
Action required: 705 - Other - as specified
Resolved 19 July 2005
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 19 May 2005 Resolved
Provide proof of operation of the overspeed trip for the #2 Turbo generator.
Due 29 July 2005
Resolved 19 July 2005
Engineering › Steam Boiler (propulsion) › Superheater
Issued 19 May 2005 Resolved
Provide proof of operation of low drum, super heater pilot and combined safety valves on the starboard boiler.
Due 29 July 2005
Resolved 19 July 2005
Engineering › Steering Gear System › Actuator
Issued 19 May 2005 Resolved
Repair oil leak on the lilt plate actuator shaft seal starboard steering gear.
Due 29 July 2005
Resolved 19 July 2005
Fire Fighting › Structural - A Class Divisions › Cargo Pump Rooms
Issued 19 May 2005 Resolved
Make proper repairs to the 1/2 inch hole in frame 1-42 bulkhead port side aft of the distilling plant.
Due 29 July 2005
Resolved 19 July 2005
Lifesaving › Lifebuoys › Serviceable
Issued 19 May 2005 Resolved
Remove 3 non servicable ring life buoys.
Due 29 July 2005
Resolved 19 May 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2005 Resolved
Renew ring life buoy floating waterlight.
Due 29 July 2005
Resolved 19 May 2005
Electrical › Electric Generation Source (service) › Number of Sources
Issued 10 June 2004 Resolved
Prior to leaving port the vessel shall demonstrate over speed trip safety, and reverse power relay function of both ships service turbine generators. LEGACY COMPONENT DESC: Generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 May 2004 Resolved
Service starboard #1 Life Boat portable fire extinguishers.
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 19 May 2004
Resolution: Serviced portable fire extinguishers.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 19 May 2004 Resolved
Service and charge SCBA cylinders prior to activation.
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 19 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 19 May 2004 Resolved
Repair hospital space head door knob.
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 19 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 19 May 2004 Resolved
Clean and organize hospital space prior to activation. LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 19 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2004 Resolved
Install light cover for light located in passageway near "Able Seaman" State room 1-117-1.
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 19 May 2005
Engineering › Steam System (main) › Valve, Relief
Issued 19 May 2004 Resolved
With both propulsion boilers on line, demonstrate hand relieving of safety relief valves, automation procedures as directed by attending marine inspector, and safety shutdowns including forced drat fan shut-down.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2005
Resolved 19 May 2004
Construction/Loadline › Structures
Issued 7 March 2003 Resolved
Repair vent closure within aft paint locker. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 10 March 2003
Construction/Loadline › Penetrations
Issued 7 March 2003 Resolved
Repair water tight hatch in way of aft line storage access due to pinholes in coaming of hatch. LEGACY COMPONENT DESC: Watertight hatch
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service)
Issued 7 March 2003 Resolved
Repair doors on electrical power panel in way of motor generator room. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 10 March 2003
Documentation › Safety/Response Plans/Programs
Issued 6 March 2003 Resolved
Provide approved Fire Control Plan for vessel. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 19 May 2004
Resolution: Provided approved FCP.
Communications › Alarms/Indicators
Issued 6 March 2003 Resolved
Repair and demonstrate operation of General Alarm bell located on main deck port side above water tight hatch 1-113-2. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 15 March 2003
Communications › Alarms/Indicators
Issued 6 March 2003 Resolved
Repair and demonstrate operation of General Alarm bell located after end of shaft alley. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 8 March 2003
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 6 March 2003 Resolved
Update, with amendment, the Oil Transfer Procedures per 33 CFR 155.750 (1), (2) (ii), and (4). LEGACY COMPONENT DESC: Transfer Procedures
Due 6 September 2003
Resolved 19 July 2005
Construction/Loadline › Structures
Issued 6 March 2003 Resolved
Repair holes in structural steel in way of main deck cargo trunks on 2 forward motor generator houses. LEGACY COMPONENT DESC: Ventilators
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 11 March 2003
Electrical › Electrical Distribution System (service)
Issued 5 March 2003 Resolved
Remove lay-up motor heating bands from motors throughout ship as indicated by attending marine inspector. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2003
Resolved 10 March 2003
Resolution: Wires have been disconnected from power source, coiled up, and tagged out of service. If vessel is activated for deployment all heater wiring shall be removed.
Electrical › Electrical Distribution System (emergency)
Issued 5 March 2003 Resolved
Provide suitable cover for exposed wires on light for upper sight glass on port boiler. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2003
Resolved 1 April 2003
Electrical › Lighting (service)
Issued 5 March 2003 Resolved
Provide and install new light cover/cage on lighting fixture located lower port engine room adjacent to CH water circulation pump. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2003
Resolved 1 April 2003
Fire Fighting › Fire Hydrants
Issued 5 March 2003 Resolved
Provide and install required firefighting equipment. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 10 March 2003
Lifesaving › Inflatable Liferafts
Issued 5 March 2003 Resolved
Properly install all liferaft and hydrostatic release appliances on board vessel. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 10 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 5 March 2003 Resolved
Remove portable freon cylinders from DC heater space and stow in appropriate hazardous locker.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 10 March 2003
Operations/Management › FireFighting
Issued 5 March 2003 Resolved
Prior to departure from port conduct fire and abandon ship drills. LEGACY COMPONENT DESC: Drills
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2003
Electrical › Lighting (emergency)
Issued 12 December 2002 Resolved
Provide operable emergency lights on bridge (2 were inoperable). LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 12 December 2003
Resolved 10 March 2003
Accommodation/Occupational Safety › Heating
Issued 12 December 2002 Resolved
Repair steam piping supports (3) for dehumidifier located on deck 3 cargo hold starboard side overhead as indicated by attending marine inspector. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 December 2002 Resolved
Install new cover on outlet box located port side aft of dishwasher in crews galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 5 March 2003
Electrical › Electrical Distribution System (service)
Issued 12 December 2002 Resolved
Install holding screw on access door to booster heater located in galley. LEGACY COMPONENT DESC: Junction Box
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2003
Resolved 5 March 2003
Lifesaving › Lifeboat › Propulsion Engine
Issued 12 December 2002 Resolved
Demonstrate operation of propulsion engine on both port and starboard lifeboats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2003
Lifesaving › Lifeboat
Issued 12 December 2002 Resolved
Repair or renew exhaust pipe on port lifeboat. LEGACY COMPONENT DESC: Exhaust Pipe
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2003
Fire Fighting › Fire Hydrants
Issued 12 December 2002 Resolved
Repair pipe support bracket on number 1 fire station. LEGACY COMPONENT DESC: Condition
Due 30 April 2003
Resolved 11 March 2003
Lifesaving › Launching Appliances
Issued 12 December 2002 Resolved
Repair port lifeboat davit in way of rust in support structure. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 10 March 2003
Navigation
Issued 22 October 2001 Resolved
Prove proper operation of pilothouse EOT. Correct prior to activation, or not later than compliance date, whichever occurs first.
Condition: Unknown
Due 22 October 2002
Resolved 21 December 2001
Resolution: Conducted satisfactory test of the EOT from the pilot house and the engine room console.
Engineering
Issued 22 October 2001 Resolved
Prove proper operation (i.e, maintain w/in normal operating parameters) of stbd boiler water treatment. _x001C_ Correct prior to activation, or not later than compliance date, whichever occurs first.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Documentation
Issued 22 October 2001 Resolved
Provide onboard a current Fire Control Plan IAW 46CFR91.55-5(d). Correct prior to activation, or not later than compliance date, whichever occurs first. (Note: Originally issued for 1 year from COI IAW MARAD MOU. At operator's request, compliance date extended an additional 6 months (30Apr03).
Condition: Unknown
Due 30 April 2003
Resolved 6 March 2003
Construction/Loadline
Issued 5 October 2001 Resolved
Repair to original, wasted area of deck, inside #2 deck winch house, I.W.O.frames 86-89, port side.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
Gouge and reweld pin ho;e in seam weld, #7 aft ballast tank, port side aft.Prove watertight integrity of tank.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
Adjust and prove watertight integrity of the followingWTDs and cargo hatch doors: WTD 1-113-1 & 1-113-2; #3 flush cargo hatch; #4 flush cargo hatch; #4 raised cargo hatch.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Engineering
Issued 5 October 2001 Resolved
Repair/renew wasted area of stbd main condenser sea scoop.
Condition: Unknown
Due 5 February 2002
Resolved 21 December 2001
Resolution: Conducted satisfactory fit-up, back gouge and final air test on new condenser sea scoop.
Engineering
Issued 5 October 2001 Resolved
Open and make ready for internal examination, #5 centerline D/B fuel oil tank.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
Repair wasted conduit and install missing conduit and piping brackets in forward peak ballast tank.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
Reweld vertical stiffener, #2 deep dallast tank, forward bulkhead, 2nd stiffener from centerline to stbd.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
Repair to original, wasted area of frame 38, stbd side I.W.O. D/B tank top.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Engineering
Issued 5 October 2001 Resolved
Renew the following port boiler main steam piping flange gaskets:_x001C_ Superheater inlet flange; Secondary main steam stop inlet flange; Control desuperheater bypass flange.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Engineering
Issued 5 October 2001 Resolved
Make permanent repairs to lower section of stbd fuel oil settler tank sounding tube, located I.W.O. #4 hold, second deck.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Engineering
Issued 5 October 2001 Resolved
Repair to original, wasted area of machinery space forward D/B fuel oil tank top, I.W.O. frames 125-127, between after stbd boiler foundations.
Condition: Unknown
Due 5 February 2002
Resolved 21 December 2001
Resolution: Conducted satisfactory fit-up, back gouge and final air test on inserted area.
Documentation
Issued 9 February 2001 Resolved
CONDUCT INSPECTION FOR CERTIFICATION PRIOR TO OPERATING VESSEL, IN ACCORDANCE WITH MARAD USCG MOU NOT LATER THAN 09 FEB 2002.
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Engineering
Issued 1 April 1999 Resolved
PROVE PROPER OPERATION OF PORT BOILER SUPERHEATER SAFETY. THIS ITEM TO BE COMPLETED PRIOR TO ACTIVATION OR NOT LATER THAN 15MAY99._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Fire Fighting
Issued 1 April 1999 Resolved
REPLACE HEAT ACTUATOR FOR FIXED CO2 SYSTEM AND PROVE PROPER OPERATION IN FWD BOS'N STORES, 1ST PLATFORM DECK. THIS ITEM TO BE COMPLETED PRIOR TO ACTIVATION OR NOT LATER THAN 15MAY99.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 1 April 1999 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS PRIOR TO ACTIVATION.
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Lifesaving
Issued 25 June 1998 Resolved
Conduct fire & boat drills prior to activation.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 21 January 1998 Resolved
Submit repair proposal for starboard gunnle and holed starboard quarter, inboard port lifeboat. Make repairs as necessary.
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Engineering
Issued 21 January 1998 Resolved
Repair missing refractory area in firebox overhead center directly over thescreen tubes.
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Engineering
Issued 21 January 1998 Resolved
Prove proper valve internals used in authorized repairs to safety valves inboth boilers.
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Engineering
Issued 21 January 1998 Resolved
Set and seal all boiler safeties at next lightoff of boilers or 30Mar98 whichever comes first.
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Electrical
Issued 9 May 1997 Resolved
Repair ground fault light indicators at engine control console and emergency generator switchboard.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Navigation
Issued 9 May 1997 Resolved
Repair/replace wasted ship whistle steam line bridge deck.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Electrical
Issued 9 May 1997 Resolved
Remove deadended cable and scure bulkhead penetration on weatherdeck acrossfrom liferaft starboard side.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Engineering
Issued 9 May 1997 Resolved
Replace lightbulb for starboard boiler water level gauge illumination.
Condition: Unknown
Due 30 May 1997
Resolved 13 May 1997
Accommodation/Occupational Safety
Issued 9 May 1997 Resolved
Properly & safely run air ejector drain/blow out line for evaporator.
Condition: Unknown
Due 30 May 1997
Resolved 13 May 1997
Electrical
Issued 9 May 1997 Resolved
Properly mark following emergency lighting: lower level E.R. forward and aft bulkhead lights (2); shaft alley aft & forward end lights.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Lifesaving
Issued 9 May 1997 Resolved
Remove hasp arrangement from weather door (wea-1-199-1) for aft steering emergency escape.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Accommodation/Occupational Safety
Issued 9 May 1997 Resolved
Replace damaged section of hand railing on fly bridge.
Condition: Unknown
Due 30 May 1997
Resolved 13 May 1997
Electrical
Issued 9 May 1997 Resolved
Replace E-light element shaft alley aft.
Condition: Unknown
Due 30 May 1997
Resolved 13 May 1997
Construction/Loadline
Issued 9 May 1997 Resolved
Provide a means for preventing direct overboard discharge from bilges.
Condition: Unknown
Due 30 May 1997
Resolved 18 June 1997
Engineering
Issued 9 May 1997 Resolved
Provide proof of ASME certification for ship service air receiver.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 9 May 1997 Resolved
Replace damaged insulation for control desuperheater line under starboard boiler.
Condition: Unknown
Due 30 May 1997
Resolved 13 May 1997
Navigation
Issued 1 May 1997 Resolved
Replace the shaft key connecting the rotary hydraulic unit to the rotary actuator assembly on the port steering unit which came adrift from the key way.
Condition: Unknown
Due 10 January 2002
Resolved 21 December 2001
Lifesaving
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, PROVIDE 13 ADDITIONAL LIFEJACKETS. VESSEL IS LIMITED TO CARRYING 46 "OTHER CREW" (TOTAL: 67 PERSONS) UNTIL THE ABOVE EQUIPMENT IS ABOARD.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Engineering
Issued 27 August 1996 Resolved
LAG STARBOARD BOILER CASING AT THE BASE OF THE STACK REAR OF THE BOILER.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Electrical
Issued 27 August 1996 Resolved
MARK UNMARKED EMERGENCY LIGHTING WITH "E"'S.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Unknown
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, REPACK LEAKING BOILER VALVES, FIRE PUMP (EMERGENCY) AND AUXILIARY CONDENSATE PUMP #1.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Lifesaving
Issued 27 August 1996 Resolved
CLEAN UP HYDRAULIC OIL BELOW SSTG #1.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Engineering
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, REPACK LEAKING FUEL OIL VALVES ON MAIN FUEL LINE TO PORT BOILER (2 VALVES).
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Engineering
Issued 27 August 1996 Resolved
LAG DESUPERHEATER PIPING BELOW PORT BOILER (AFT OUTBOARD CORNER).
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Engineering
Issued 27 August 1996 Resolved
PROVIDE AUDIOGAUGING REPORT FOR PORT BOILER GENERATING TUBES.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Unknown
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, TEST SECTION 10 (TRIAL FOR IGNITION) OF THE AUTOMATION PROCEDURES (NEW PROCEDURE ADDED TO TEST FOR IGNITER INSERTED BUTNOT ENERGIZED).
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Documentation
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, PROVIDE THE FOLLOWING FOR OIL TRANSFER PROCEDURES: CROSSOVER STATUS BETWEEN FUEL AND BALLAST SYSTEMS, PROCEDURES FOR FUEL TRANSFER WITHIN VESSEL.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Fire Fighting
Issued 27 August 1996 Resolved
PROVIDE CLOSURE MECHANISM FOR SUPPLY VENT (NATURAL) IN E/R PAINT LOCKER.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Documentation
Issued 27 August 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Engineering
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, DEMONSTRATE "FAST" OPERATION OF THE STARBOARD FORCED DRAFT FAN.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Accommodation/Occupational Safety
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, PROVIDE DATA PLATES FOR CONTROL AIR AND SHIP'S SERVICE AIR PRESSURE VESSELS.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Construction/Loadline
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, REPLACE GASKET ON W.T.D. #10.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Lifesaving
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, DEMONSTRATE PROPER OPERATION OF BRIDGE COMBUSTABLE GAS INDICATOR, CARBON MONOXIDE INDICATOR, CARGO HOLD VENTILATION FAN INDICATOR.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Engineering
Issued 27 August 1996 Resolved
PROVE PROPER AUTOMATIC OPERATION OF STBD STEAM STANDBY L/O PUMP UPON LOSS OF STBD ELEC L/O PUMP. THE STEAM PUMP IS STILL OPERATIONAL MANUALLY.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Construction/Loadline
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, DEMONSTRATE PROPER GASKET CONTACT AT BOTTOM OF W.T.D. #5.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Accommodation/Occupational Safety
Issued 27 August 1996 Resolved
PRIOR TO ACTIVATION OR COI, REPAIR THERMOMETER ON AFT PART OF REEFER. MACHINERY.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Fire Fighting
Issued 27 August 1996 Resolved
REPAIR HOLE IN FORE AND AFT PASSAGEWAY, PORT SIDE, FORWARD OF THE JUNIOR ENGINEER STATEROOM AT 02A-134-4, CLASS A FIRE BOUNDARY.
Condition: Unknown
Due 27 September 1996
Resolved 3 October 1996
Construction/Loadline
Issued 27 August 1996 Resolved
RENEW GOOSENECK VENT TO #6 POTABLE WATER RESERVE FEED WATER TANK.
Condition: Unknown
Due 27 September 1996
Resolved 3 October 1996
Electrical
Issued 27 August 1996 Resolved
PROVE PROPER OPERATION OF FIRST TWO EMERGENCY ESCAPE LIGHTS IN SHAFT ALLEY ESCAPE NEAREST BOTTOM OF VSL.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Construction/Loadline
Issued 27 August 1996 Resolved
ENSURE THAT ALL DECK HOUSE CONDUITS ARE IN PLACE IN EXTERIOR WATERTIGHT BULKHEADS.
Condition: Unknown
Due 27 September 1996
Resolved 3 October 1996
Construction/Loadline
Issued 27 August 1996 Resolved
PROVIDE NUTS TO SECURE TANK ACCESS PLATE IN PORTSIDE SHAFT ALLEY FOR PORT SLOP TANK.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Lifesaving
Issued 27 August 1996 Resolved
PROVIDE BOLT FOR PORTSIDE LIFEBOAT ELECTRIC CONTROLLER BOX.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Electrical
Issued 27 August 1996 Resolved
REPLACE BROKEN LIGHT COVERS IN ENGINE ROOM.
Condition: Unknown
Due 27 September 1996
Resolved 21 October 1996
Electrical
Issued 7 June 1996 Resolved
On 7 June 96, the M/V METEOR tested the new power take off drive gears for the governor/lube oil pump. During the test, the new gears failed within_x001C_ 20 minutes of warm-up operations.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Engineering
Issued 16 May 1995 Resolved
SUBMIT BOILER MANAGEMENT OPERATION TESTING PROCEDURES TO COAST GUARD FOR APPROVAL.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Construction/Loadline
Issued 16 May 1995 Resolved
MAKE AFT BULKHEAD IN WINCH CONTAINMENT ROOM AT FRAME 200 WATERTIGHT. (PLUG TWO HOLES 18" OFF DECK)_x001C_ COMPLETE PRIOR TO ACTIVATION.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Construction/Loadline
Issued 16 May 1995 Resolved
TEST WATERTIGHT DOORS FOR OPERATION AND WATER TIGHT INTEGRITYAS FOLLOWS: 1,2,5,6,13,15,16,3-128-3,3-128-4,PORT SIDE SIDE-PORTS IN HOLDS 3 & 4._x001C_ THIS ITEM IS TO BE COMPLETED PRIOR TO ACTIVATION.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Lifesaving
Issued 16 May 1995 Resolved
CONDUCT LIFEBOAT WEIGHT TESTS ON PORT & STBD BOATS.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Construction/Loadline
Issued 14 March 1995 Resolved
MAKE APPLICABLE REPAIRS TO BHD #39 AT SECOND DECK STBD SIDE.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Engineering
Issued 2 November 1994 Resolved
PROVIDE 1.25 MAWP HYDRO ON BOTH BOILERS PRIOR TO ACTIVATION OR REQUEST EXTENSIONS FOR BOTH HYDROS. HYDROS TO BE WITNESSED BY CG INSPECTOR.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Engineering
Issued 2 November 1994 Resolved
PROVIDE CG APPROVED AUTOMATION PROCEDURES FOR NEW TMS AUTOMATION SYSTEM FORENGINE ROOM.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Construction/Loadline
Issued 24 March 1994 Resolved
PROVIDE REAIR PROPOSAL FOR PERM. REPAIRS TO FRAMES 187-194 STBD. SIDE (SHAFT ALLEY). PROPOSAL TO INCLUDE INTENDED DATE OF REPAIR, I.E. DRYDOCK._x001C_
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Navigation
Issued 24 March 1994 Resolved
PROVIDE UPDATED MAG. COMPASS DEVIATION CARD.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Construction/Loadline
Issued 24 March 1994 Resolved
MAKE APPLICABLE REPAIRS TO BHD #39 @ 2ND DECK STBD SIDE UPON APPROVAL OF PROPOSAL BY OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 24 March 1994 Resolved
MAKE HULL REPAIRS AT FRAMES 108-111, 120-127, AND 142-147 IAW "JAMES RAESIDE CO." SURVEY REF NO. 1690 OF 18FEB94.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 24 March 1994 Resolved
END FOR END LIFEBOAT FALLS AND CONDUCT INSTALLATION TESTS FOR BOTH LIFEBOATS. ITEM TO BE COMPLETE UPON RETURN VOYAGE OR 25JUN94 WHICH EVER ISFIRST. 30MAR94 #2 L/B WT. TEST CONDUCTED & SAT.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
HAVE ELEVATORS INSPECTED IAW ANSI A17.1.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 17 February 1994 Resolved
STORM SURGE CAUSED HULL AND FRAME DAMAGE IWO FRAMES #109, 124, & 144, STARBOARD SIDE.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Engineering
Issued 7 December 1993 Resolved
PROVIDE AUTOMATION PROCEDURES FOR MAIN PROPULSION BOILER.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Construction/Loadline
Issued 7 December 1993 Resolved
PROVIDE REPAIR PROPOSAL TO CROP & RENEW METAL WASTED IN EXCESS OF 25% OF ORINGINAL SCANTLINGS FOR WT BLKH #39 FOR A HEIGHT OF 12" ABOVE EACH CARGO DECK - SAME FOR BLKH #61 AT INTERSECTION W/2ND DECK.
Condition: Unknown
Due 24 March 1994
Resolved 25 March 1994
Construction/Loadline
Issued 7 December 1993 Resolved
PROVIDE A REPAIR PROPOSAL FOR FRAMES 187 THRU 194 WASTED THROUGH AT INTERSECTION WITH DECK IN SHAFT ALLEY STBD SIDE AS WELL AS FOR AFTERMOST TWO SWASH BLKHS IN SHAFT ALLEY BILGE STARBOARD SIDE.
Condition: Unknown
Due 24 March 1994
Resolved 25 March 1994
Engineering
Issued 7 December 1993 Resolved
PROVE PROPER SETTING OF CONTROL AIR PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 24 March 1994
Resolved 25 March 1994
Documentation
Issued 7 December 1993 Resolved
SHOW THAT FUEL OIL TRANSFER PROCEDURES MEET 33 CFR 154.310)(a)(5)(ii)
Condition: Unknown
Due 24 March 1994
Resolved 25 March 1994
Lifesaving
Issued 7 December 1993 Resolved
(CONTINUED FROM CG835 7A): 2 RING BUOYS; 74 SEA SICK BAGS; SEA SICK MEDICINE; 1 SEARCH LIGHT; SURVIVAL MANUAL; 8 THERMAL PROTECTIVE AIDS; SOALSCOVER; 31LBS ADD'L PROVISIONS; AND A RADAR REFLECTOR.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
TEST GENERAL ALARMS.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Accommodation/Occupational Safety
Issued 7 December 1993 Resolved
PROVIDE BELT GUARD FOR MSD BLOWER.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
PROVIDE SATISFACTORY COVERS FOR BILGE OPENING IN WAY OF EMERGENCY ESCAPE INSHAFT ALLEY.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
PROPERLY MOUNT HIGH LEVEL ALARM IN SHAFT ALLEY.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Engineering
Issued 7 December 1993 Resolved
REPAIR SPALLING OF REFRACTORY IN PORT BOILER SUPERHEATER VESTIBULE AFT.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Deck/Cargo
Issued 7 December 1993 Resolved
PROVIDE STANDARD DISCHARGE CONNECTION AS REQUIRED BY 33 CFR 155.430.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Engineering
Issued 7 December 1993 Resolved
REPAIR REACH ROD SUPPORT FOR STBD MAIN STEAM OUTLET VALVE ON UPPER LEVEL.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Engineering
Issued 7 December 1993 Resolved
PROVIDE MANUFACTURER'S RECOMMENDATION FOR WHAT TO DO WITH RUPTURED AND JAGGED SUPER HEATER TUBES IN STBD BOILER.
Condition: Unknown
Due 7 December 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
(CONTINUED FROM CG835 6A): SEA SICK MEDICINE; SEARCH LIGHT; 8 THERMAL PROTECTIVE AIDS; SOLAS COVER; RADAR REFLECTOR.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
FOR #1 LIFE BOAT PROVIDE THE FOLLOWING: 2 ADD'L CAN OPENERS; ILLUMINATION FOR COMPASS; WATER TIGHT 1ST AID KIT W/CURRENTLY DATED CONTENTS; 6 CURRENT FLASH LIGHT BATTERIES; 2 RING BUOYS; REPLACE 3 CRACKED OARS; PROPERLY MARKED (PAINTED) SWEEP; 74 SEA SICK BAGS; (CONTINUED ON CG835 6B)
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
FOR #2 LIFE BOAT PROVIDE THE FOLLOWING: 1 ADD'L BAILER; 1 ADD'L BOAT HOOK (W/ROUND TIP); TWO ADD'L CAN OPENERS; COMPASS ILLUMINATION; WATER TIGHT 1STAID KIT W/CURRENTLY DATED CONTENTS; 6 CURRENTLY DTD FLASH LIGHT BATTERIES &1 SPARE BULB; TWO ADD'L HEAVING LINES; (CONTINUED ON CG835 7B)
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Fire Fighting
Issued 7 December 1993 Resolved
SECURE FIRE PLAN TUBE TO BLK.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Accommodation/Occupational Safety
Issued 7 December 1993 Resolved
REPAIR WINDOW IN BRIDGE, LOCATED FIVE WINDOWS AFT OF PRT DOOR. WINDOW DOESN'T ROLL UP.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
PROVE PROPER OPERATION OF SHAFT ALLEY DOOR FROM SHAFT ALLEY SIDE.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
MAKE WT THE PENETRATIONS THRU BLK BETWEEN E/R & SHAFT ALLEY LOCATED TO STB OF SHAFT ALLEY WTD.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Deck/Cargo
Issued 7 December 1993 Resolved
REPAIR VALVE FOR CHAIN LOCKER SOUNDING PIPE.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Fire Fighting
Issued 7 December 1993 Resolved
PROTECT FROM MECHANICAL DAMAGE THE HEAT ACTIVATING LINE FOR FIXED CO2 SYSTEM LOCATED 2ND DECK BOS'NS STORES OR REMOVE ALL SHACKLES/HOOKS/ETC. FROM AREA AND CUT OUT STORAGE RACK.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
INSPECT EMERGENCY GEAR LOCKERS.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
REPLACE VALVE HANDLE FOR OVERBOARD VALVE FOR BOS'N STORES BILGE SYSTEM._x001C_
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Fire Fighting
Issued 7 December 1993 Resolved
SERVICE ALL FIRE DAMPERS THROUGH OUT VSL & DEMONSTRATE SAT OPERATION W/MARINE INPSECTOR PRESENT.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
CONDUCT SAT HOSE TEST OF ALL CARGO HATCHES & SIDE PORTS.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
CONDUCT SAT CHALK TESTS OF ALL WTD'S.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Lifesaving
Issued 7 December 1993 Resolved
PROPERLY STENCIL ALL RING BUOYS.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 7 December 1993 Resolved
SUBMIT A REPAIR PROPOSAL TO EXPLAIN THE REPAIR DONE ON THE HOLE IN #3 HATCHAT STANCHION BASE ON LEAF 2 PRT SIDE.
Condition: Unknown
Due 20 March 1994
Resolved 20 March 1994
Lifesaving
Issued 7 December 1993 Resolved
METAL BAND & MAKE PROPER DECK/BLK PENETRATIONS FOR WIRE RUN IN SHAFT ALLEY ESCAPE TRUNK.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Fire Fighting
Issued 7 December 1993 Resolved
PROPERLY MARK FWD BOSN STORES TO INDICATE CO2 PROTECTION.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Fire Fighting
Issued 7 December 1993 Resolved
REPAIR AND CONDUCT SAT TEST OF HEAT ACTIVATING TRIP FOR 1ST PLATFORM BOS'NSSTORES FWD CO2 SYSTEM.
Condition: Unknown
Due 7 January 1994
Resolved 14 January 1994
Engineering
Issued 19 November 1993 Resolved
PROVIDE HAND RELIEVING GEAR FOR DC HEATER RELIEF VALVE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Fire Fighting
Issued 19 November 1993 Resolved
REPAIR/REPLACE SECURING DEVICES TO EXTERNAL WEATHER DECK FIRE SCREEN DOORS SO DOORS WILL SHUT & SECURE SHUT.
Condition: Unknown
Due 30 November 1994
Resolved 14 January 1994
Fire Fighting
Issued 19 November 1993 Resolved
MAKE ALL PENETRATIONS OF BULKHEADS PROPER TO MAINTAIN STRUCTURAL FIRE PROTECTION INTEGRITY (IE: 2 A/E STATEROOM NEXT TO PORTLIGHT) PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Engineering
Issued 19 November 1993 Resolved
REPACK VALVE FOR THROTTLE SUPPLY DRAIN LOCATED BY #1 FEED PUMP. TO BE COMPLETED ONE YEAR FROM CERTIFICATION OR NEXT OPERATIONAL PERIOD, WHICHEVEROCCURS FIRST._x001C_ _x001C_
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Fire Fighting
Issued 19 November 1993 Resolved
PROVIDE LOCAL SWITCHES FOR FIRE SCREEN DOORS PORT AND STARB TO ENGINE RM
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Construction/Loadline
Issued 19 November 1993 Resolved
DEMONSTRATE ABILTY OF STEAM DRIVEN PUMP TO PUMP BILGES FURTHEST FROM PUMP_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Lifesaving
Issued 19 November 1993 Resolved
PROVIDE METAL CAP AT BASE OF PORT LIFEBOAT PLYWOOD RUDDER.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 19 November 1993 Resolved
SUBMIT PLANS AND INSTALL BRIDGE AIR CONDITIONERS IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 19 November 1993 Resolved
PROVIDE SOLAS COVER FOR PORT LIFEBOAT PRIOR TO SAILING FOREIGN AND NOT MORETHAN 200 MILES FROM SHORE, BUT NOT LATER THAN 29DEC93.
Condition: Unknown
Due 29 December 1993
Resolved 14 January 1994
Fire Fighting
Issued 19 November 1993 Resolved
CAP BULKHEAD PENETRATION TO MOTOR CONTROL ROOM STBD SIDE MAIN DECK, PRIOR TO SAILING.
Condition: Unknown
Due 30 November 1994
Resolved 14 January 1994
Engineering
Issued 19 November 1993 Resolved
TEST F/O HIGH TEMP ALARM_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 19 November 1993 Resolved
PROVIDE LAUNCHING INSTRUCTIONS FOR STBD LIFERAFT.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Unknown
Issued 19 November 1993 Resolved
FREE UP AND LABLE VALVE 4-127-4
Condition: Unknown
Due 30 November 1994
Resolved 14 January 1994
Fire Fighting
Issued 19 November 1993 Resolved
REPAIR LEAKING VALVE AT FIRE STATION #13.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 19 November 1993 Resolved
REMOVE ALL PLASTIC WIRE WRAPS ON WIRE RUNS AND PROPERLY SECURE WIRES (IE: BY FRAME 110 MAIN DECK OVERHEAD PORT TO STBD).
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 19 November 1993 Resolved
REPAIR PIPE HANGER FOR PIPE IN WAY OF WALKWAY ON FORWARD SIDE OF STARB STEAM DRUM.
Condition: Unknown
Due 9 December 1993
Resolved 9 December 1993
Navigation
Issued 19 November 1993 Resolved
PROVE OPERATION OF POWER FAILURE AUDIO/VISUAL ALARMS OF NAVIGATION LIGHTS UPPER FUSES.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Unknown
Issued 19 November 1993 Resolved
SECURE PORT/STBD MANHOLE ACCESSESS TO SERVICEVENT FAN EXHAUST 1-126-1 & 1- 126-2.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 19 November 1993 Resolved
PROVIDE FLAME SAFETY LAMP FOR BOTH EMERGENCY GEAR LOCKERS.
Condition: Unknown
Due 30 November 1994
Resolved 14 January 1994
Electrical
Issued 13 October 1993 Resolved
COMPLETE MARKING OF EXTERIOR "E" LIGHTS.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Documentation
Issued 13 October 1993 Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33 CFR 155.750
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Electrical
Issued 13 October 1993 Resolved
RE-INSTALL MISSING LIGHT COVERS, PORT MAIN DECK, INTERIOR PASSAGE.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Electrical
Issued 13 October 1993 Resolved
RECONNECT/ MAKE OPERATIONAL CARBON MONOIDE SIREN, #5 LEVEL, LOWER #4 HOLD, FORWARD BULKHEAD.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Lifesaving
Issued 13 October 1993 Resolved
REPAIR OR REPLACE BILGE PUMP TO PORT LIFE BOAT.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Construction/Loadline
Issued 13 October 1993 Resolved
GAS FREE BY MARINE CHEMIST #7 FWD P/S (COMMON TANK) SALT WATER BALLAST TANKS AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Deck/Cargo
Issued 13 October 1993 Resolved
REPAIR AND PROVE OPERATION OF PORT ANCHOR WINDLASS.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Engineering
Issued 13 October 1993 Resolved
PROVIDE RELIEF VALVE FOR CONTROL AIR RECEIVER (MAWP 125#) OR PROVE PROPER OPERATION OF EXISTING VALVE.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Construction/Loadline
Issued 13 October 1993 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR AND PROVIDE MANUFACTURERS INSTRUCTIONS.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Navigation
Issued 13 October 1993 Resolved
PERMANENTLY MARK WITH PLASTIC LABEL TAG "OPEN POSITION" OF VALVE #12 FOR STEERING SYSTEM DURING EMERGENCY OPERATIONS.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Engineering
Issued 13 October 1993 Resolved
SET AND SEAL ALL STBD BOILER SAFETY VALVES AND THE PORT SUPERHEATER SAFETY VALVE.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Construction/Loadline
Issued 5 March 1992 Resolved
REPAIR AND PROVE PROPER OPERATION OF WATER-TIGHT DOORS #2-117-2, 3-142-2, AND 2-142-1, ENSURING DOGS LAND ON STRIKE PLATES AND DOOR PROVIDES WATER- TIGHT SEAL.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Navigation
Issued 5 March 1992 Resolved
REMOVE OR PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR, STEERING CONSOLE, AND ENGINE ORDER TELEGRAPH ON FLYING BRIDGE.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Engineering
Issued 5 March 1992 Resolved
INSTALL 30 X 30 MESH FLAME SCREENS ON #5 CENTER FUEL OIL VENT, STARBOARD FUEL OIL SETTLER TANK VENT AND #5 AFT FUEL OIL TANK VENT, ALL LOCATED STARBOARD SIDE AMIDSHIP.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 5 March 1992 Resolved
INSTALL A CRADLE OR MOUNTING BRACKETS FOR 8 PERSON LIFERAFT FORWARD.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Lifesaving
Issued 5 March 1992 Resolved
STENCIL VESSEL NAME ON 16 NEW SOLAS 83 APPROVED LIFEJACKETS.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Electrical
Issued 5 March 1992 Resolved
INSTALL PROTECTIVE COVERS ON LIGHT FIXTURES IN ENGINE ROOM.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Engineering
Issued 31 July 1991 Resolved
PROVIDE COAST GUARD APPROVED DRAWINGS FOR INSTALLATION OF DE LAVAL EVAP ANDASSOC EQUIPT _x001C_
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Deck/Cargo
Issued 31 July 1991 Resolved
PROVE PROPER OPERATION OF BOTH CARBON MONOXIDE AND COMBUSTABLE GAS DECTECTION SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Engineering
Issued 31 July 1991 Resolved
PROVIDE COAST GUARD APPROVED AUTO TEST PROCEDURE AND PROVE OPERATION TO_x001C_ COAST GUARD INSPECTOR.
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Unknown
Issued 31 July 1991 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Electrical
Issued 16 May 1991 Resolved
PROVE PROPER OPERATION OF MAIN ELECTRICAL BREAKER #2 TURBO GENERATOR, TO BECOMPLETED TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Fire Fighting
Issued 25 April 1991 Resolved
MAKE PERMANENT REPAIRS TO SUPPLY DUCT VENT 2-135-2 IN WAY OF VENT DAMPER 3-135-2 WHERE RED-HANDED.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Engineering
Issued 25 April 1991 Resolved
PROVIDE COAST GUARD APPROVED AUTOMATION TEST PROCEDURE FOR BOILERS AND PROVE PROPER OPERATION OF COAST GUARD APPROVED TEST PROCEDURE.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Lifesaving
Issued 25 April 1991 Resolved
PROVE PROPER OPERATION OF COMBUSTIBLE GAS DETECTION SYSTEM AND CARBON MONOXIDE DETECTION SYSTEM TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Engineering
Issued 25 April 1991 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR, AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Engineering
Issued 25 April 1991 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD BOILER SAFETIES BLOWDOWN DISCHARGE PIPING.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Engineering
Issued 25 April 1991 Resolved
INSURE THAT ALL BOILER MOUNTINGS ARE OPENED FOR INSPECTION.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 25 April 1991 Resolved
READJUST OR RESEAL MAIN DECK HATCHES NO.3 FORWARD, NO. 3 AFT NO.4 FORWARD AND NO.4 AFT TO INSURE THAT THEY ARE WATERTIGHT.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Unknown
Issued 25 April 1991 Resolved
PROVIDE COAST GUARD REVIEWED DRAWINGS FOR NEW INSTALLATION OF DE LUVAL EVAPORATOR AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Accommodation/Occupational Safety
Issued 25 April 1991 Resolved
MAKE PERMANENT REPAIRS TO RED-HANDED ELBOW ON MARINE SANITATION DEVICE CHLORINATOR PIPING.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 25 April 1991 Resolved
PROVE PROPER OPERATION OF BOTH CARBON MONOXIDE AND GASOLINE VAPOR DETECTIONSYSTEMS AT THE BRIDGE. VSL TO FOLLOW ALL GUIDELINES SET ON NATIONAL DEFENSE WAIVER MESSAGE 121849Z DEC 90 UNTIL ABLE TO COMPLY WITH THIS REQUIREMENT.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Navigation
Issued 25 April 1991 Resolved
GET ALL APPROVED NAVIGATION LIGHTS TO REPLACE PRESENT NON APPROVED LIGHTS BY NO LATER THAN NEXT DRYDOCK EXAMINATION.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Electrical
Issued 25 April 1991 Resolved
PROVE OPERATION OF ALL STOP LIGHT ANNUNCIATORS FOR REMOTE VENTILATION SHUT DOWNS AT THE BRIDGE.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Lifesaving
Issued 25 April 1991 Resolved
CONDUCT WEIGHT TEST ON STBD SIDE LIFEBOAT TO THE SATISFACTION OF A USCG MARINE INSPECTOR UPON ARRIVAL NEXT U.S. PORT.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Lifesaving
Issued 25 April 1991 Resolved
VSL IS RESTRICTED TO CARRY 61 PERSONS ONBOARD DUE TO SHORTAGE OF PFD'S AND EXPOSURE SUITS PRESENTLY ONBOARD.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Fire Fighting
Issued 20 February 1991 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE FOLLOWING SYSTEMS; SMOKE DETECTIONSYSTEM, COMBUSTIBLE GAS DETECTION SYSTEM AND CARBON MONOXIDE DETECTION SYSTEM TO THE SATISFACTION TO THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Accommodation/Occupational Safety
Issued 20 February 1991 Resolved
PROVIDE COAST GUARD APPROVED DRAWINGS FOR NEW INSTALLATION OF DE LUVAL AND CONTROL AIR COMPRESSOR/RECEIVER.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Fire Fighting
Issued 20 February 1991 Resolved
REMOVE AND REPLACE WITH U.S. COMMERCIAL STANDARD U.S. NAVY FIRE HOSES, NOZZELES AND FOAM EQUIPMENT.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Engineering
Issued 24 August 1990 Resolved
PROVIDE COAST GUARD APPROVED AUTOMATION TEST PROCEDURE FOR BOILERS AND PROVE PROPER OPERATION OF COAST GUARD APPROVED TEST PROCEDURE.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Engineering
Issued 24 August 1990 Resolved
INSURE THAT ALL BOILER MOUNTINGS ARE OPENED FOR INSPECTION.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Engineering
Issued 24 August 1990 Resolved
PROVE PROPER OPERATION OF DC HEATER RELIEF VALVE.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Engineering
Issued 24 August 1990 Resolved
REPAIR OR RENEW HOUSING FOR PUMP ON COMB. FIRST STAGE FEEDWATER HEATER.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 August 1990 Resolved
PROVE PROPER OPERATION OF THE FOLLOWING TESTS ON THE EMERGENCY GENERATOR: OVERSPEED, LOW LUBE OIL ALARM AND LOW LUBE OIL TRIP.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Construction/Loadline
Issued 24 August 1990 Resolved
READJUST WTD 3-128-4 TO INSURE THAT IT IS WATERTIGHT.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Construction/Loadline
Issued 24 August 1990 Resolved
READJUST OR RESEAL MAIN DECK HATCHES NO. 3 FORWARD, NO. 3 AFT, NO. 4 FORWARD AND NO. 4 AFT TO INSURE THAT THEY ARE WATERTIGHT.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 August 1990 Resolved
INSTALL ELECTRICAL MATTING IN FRONT OF AND BEHIND ALL SWITCHBOARDS.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 August 1990 Resolved
RENEW OR REPAIR TACHOMETER ON NO. 1 TURBO GENERATOR.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Engineering
Issued 14 February 1990 Resolved
PROVE PROPER OPERATION OF THE ENGINE ROOM AND SHAFT ALLEY BILGE ALARMS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 14 February 1990 Resolved
REPAIR LIFEBOAT HYDRAULIC ACCUMULATOR PRESSURE GAUGES.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Electrical
Issued 14 February 1990 Resolved
PROVIDE COVERS FOR FLUORESCENT FIXTURES LOCATED IN MAIN DECK HOUSE THROUGH WAY.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Fire Fighting
Issued 14 February 1990 Resolved
STENCIL VESSEL NAME ON ALL FIRE HOSES.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 14 February 1990 Resolved
RENEW ONE (01) LIFEBOAT STORM OIL CONTAINER.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 14 February 1990 Resolved
RENEW ALL LIFEJACKET LIGHTS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 14 February 1990 Resolved
RENEW ONE (01) LIFEBOAT KEROSENE CONTAINER.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990 Resolved
PROVE SATISFACTORY PORT REDUCTION GEAR AND LINE SHAFT ALIGNMENT.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990 Resolved
REPLACE THE RELIEF VALVE ON THE 85 PSI PRESSURE VESSEL AND INSTALL A 70 PSIRELIEF VALVE OR ONE NOT TO EXCEED THE MAWP OF 85 PSI.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Fire Fighting
Issued 14 February 1990 Resolved
MOVE CO2 HOSE REEL, 2ND DECK CARGO HOLD NUMBER FIVE (05) PORTSIDE IN WAY OFAIR COMPRESSOR.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Construction/Loadline
Issued 14 February 1990 Resolved
PROVE PROPER OPERATION OF THE SHAFT ALLEY WTD REMOTE MANUAL STATION AND INDICATOR.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Accommodation/Occupational Safety
Issued 14 February 1990 Resolved
REPAIR SUPPLY VENT DUCT 2-135-2 IN WAY OF VENT DAMPER 3-135-2 WHERE HOLED.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990 Resolved
PROVIDE INSPECTION DATA ON PORT REDUCTION GEAR BULL GEAR BEARING/JOURNALS DURING LINE SHAFT ALIGNMENT.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Navigation
Issued 14 February 1990 Resolved
REPAIR OR REPLACE THE STBD ENGINE ORDER TELEGRAPH.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Electrical
Issued 14 February 1990 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY DIESEL GENERATOR AUTOSTART FUNCTION.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Electrical
Issued 14 February 1990 Resolved
REPAIR THE GROUNDS ON THE MAIN SWITCHBOARD/EMERG. SWITCHBOARD ON THE 440V- 120V BUS GROUND DECTECTORS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 14 February 1990 Resolved
REPAIR OUTBOARD GRABRAIL, NUMBER ONE (01) LIFEBOAT.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Accommodation/Occupational Safety
Issued 4 August 1988 Resolved
PROVE PROPER OPERATION OF REMOTE VENTILATION SHUTDOWN FOR MACHINERY SPACE.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Fire Fighting
Issued 4 August 1988 Resolved
PROVIDE ONE FIREMAN'S OUTFIT.
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988
Fire Fighting
Issued 1 October 1985 Resolved
PRIOR TO VESSEL BEING PLACED IN SERVICE ALL FIREFIGHTING EQUIPMENT SHALL BEINSPECTED BY A MARINE INSPECTOR.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Lifesaving
Issued 1 October 1985 Resolved
PRIOR TO THE VESSEL BEING PLACED IN SERVICE ALL LIFE SAVING EQUIPMENT SHALLBE INSPECTED BY A MARINE INSPECTOR.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Engineering
Issued 1 October 1985 Resolved
MAIN PROPULSION, ELECTRICAL GENERATING, AND STEERING SYSTEMS SHALL BE OPERATIONALLY TESTED WITH A MARINE INSPECTOR IN ATTENDANCE.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Navigation
Issued 1 October 1985 Resolved
PRIOR TO VESSEL BEING PLACED IN SERVICE ALL NAVIGATIONAL EQUIPMENT SHALL BEINSPECTED BY A MARINE INSPECTOR.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Engineering
Issued 1 October 1985 Resolved
CORRECTLY SET OVERSPEED DEVICE ON PORT MAIN ENGINE.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Fire Fighting
Issued 1 October 1985 Resolved
REPLACE ALL NAVY STYLE FIRE HOSES WITH COAST GUARD APPROVED FIRE HOSES.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Unknown
Issued 15 March 1985 Resolved
REPLACE THE CRACKED STERN RAMP DRIVE GEAR AND PROVE OPERATION OF SAME.
Condition: Unknown
Due 15 March 1985
Resolved 15 March 1985
Unknown
Issued 15 March 1985 Resolved
PROVIDE NEW TEMPERATURE OIL SEALS ON THE PORT AND STARBOARD AIR PREHEATER MOTOR GEAR BOXES.
Condition: Unknown
Due 15 March 1985
Resolved 15 March 1985

Casualty record · 1

25 December 2005Routine · role: Involved in a Marine Casualty · activity 2580843
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record