MAURY USCG vessel records Sign in
← All vessels

INGEGAS

INGEGAS is a 1981 tank ship. The Coast Guard has recorded 20 inspections since 1996, most recently in August 2008, along with 21 deficiencies and 4 operational controls.

Records from 1996 to 2008. Most recent: operational control imposed, 11 August 2008.

Built
1981
Last inspected
11 August 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8008383 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
378650
Flag
PANAMA
—
Maury page id
psix-378650

Inspections, by type

…with no type recorded14
Years with a record 6 calendar years (1996–2008)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it340343 - Dead Weight, Ton
2712 - Regulatory (Subpart C or D), Gross Ton
813 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

11 August 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3295636
7 September 2007 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3051565
6 September 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3051105
2 March 2002 Letter of Compliance (Initial/Renewal) · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1490773
2 March 2002 In-Service Inspection · Certificate of Compliance
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1600725
1 March 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1490539
16 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417157
16 June 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1127907
10 December 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 410828
10 December 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 647346
13 November 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409882
5 November 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 504992
5 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404283
5 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 774833
30 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 529609
18 January 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 399844
17 September 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 395534
13 April 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 390109
12 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389807
12 April 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1080540

Deficiency record · 21

Deck/Cargo › Inert Gas System › Boiler Uptake Valve
Issued 7 September 2007 Resolved
Boiler Uptake Valve - Unknown Cause/Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 September 2007
Resolved 7 September 2007
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 2 March 2002 Resolved
Vessels deck water spray system not operating properly; several spray nozzles failed to provide adequate pressure or coverage. (Gas Code 11.3) Vessel to repair/test to the Satisfaction of the Certificate of Fitness issuing authority prior to departure or conducting cargo operations. LEGACY COMPONENT DESC: Nozzles
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2002
Resolved 25 September 2007
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 2 March 2002 Resolved
Vessels inert gas system not operating properly. (Gas Code 9.5) Vessel to repair/test to the satisfaction of the Certificate of Fitness issuing authority prior to conducting cargo operations which require the use of the inert gas system IAW the special requirements of the Gas Code. LEGACY COMPONENT DESC: Proper Operation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 25 September 2007
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 2 March 2002 Resolved
Vessels fixed gas detection system not operating properly. Crew unable to demonstrate proper operation. (Gas Code 13.6.6) Repair/test to the satisfaction of the Certificate of Fitness issuing authority, and provide report for CG review prior to departure or conducting cargo operations.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2002
Resolved 25 September 2007
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 2 March 2002 Resolved
Deck water spray system not operating properly; several spray nozzles failed to provide adequate pressure or coverage
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2002
Resolved 4 March 2002
Resolution: Recieved class report attesting proper repairs to deck water spray system
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 2 March 2002 Resolved
Vessels fixed gas detection system not operating properly. Crew unable to demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2002
Resolved 4 March 2002
Resolution: Recieved class report attesting proposed temporary alternatives for detection.
Navigation
Issued 10 December 1997 Resolved
The person in charge/operator did not ensure the vessel had a properly operating echo depth sounder while transiting the Mississippi River.
Condition: Unknown
Due 11 December 1997
Resolved 16 December 1997
Navigation
Issued 10 December 1997 Resolved
The person in charge/operator failed to ensure the vessel had a properly operating echo depth sounder recorder while transiting the Mississippi River.
Condition: Unknown
Due 11 December 1997
Resolved 16 December 1997
Navigation
Issued 10 December 1997 Resolved
The person in charge/operator failed to provide the vessel with a current/corrected chart for the area transited. The most current chart for this area is 11370 20th ed. corrected to 47/97.
Condition: Unknown
Due 11 December 1997
Resolved 16 December 1997
Engineering
Issued 5 June 1997 Resolved
FUEL TANK FLAME SCREENS WERE HOLED, WASTED AND CLOGGED.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Documentation
Issued 5 June 1997 Resolved
VESSEL'S SHIP OIL POLLUTION EMERGENCY PLAN DID NOT HAVE THE GEOGRAPHIC SPECIFIC INFORMATION FOR COTP PHILADELPHIA ZONE.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Navigation
Issued 5 June 1997 Resolved
EMERGENCY STEERING CHANGE OVER PROCEDURES WERE MISSING THE STEERING SYSTEM DIAGRAM.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Deck/Cargo
Issued 5 June 1997 Resolved
CARGO COMPRESSORS SEALS LEAKED EXCESSIVELY. BILGES IN COMPRESSOR & MOTOR ROOMS HAD AN EXCESSIVE AMT OF HYDRAULIC OIL.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Navigation
Issued 5 June 1997 Resolved
MANEUVERING FACT SHEET WAS MISSING MOST OF THE INFORMATION REQUIRED
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Lifesaving
Issued 5 June 1997 Resolved
PORT LIFEBOAT BILGE PUMP DID NOT OPERATE CORRECTLY DUE TO HOLED PUMP SEAL
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Lifesaving
Issued 5 June 1997 Resolved
FIRE CONTROL PLAN DID NOT HAVE CORRECT VESSEL NAME; LOCATION OF EQUIPMENT WAS INCORRECT/INCOMPLETE.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 5 June 1997 Resolved
EMERGENCY FIRE PUMP EXHAUST SYSTEM LEAKED EXCESSIVELY, FILLING THE PUMP COMPARTMENT WITH EXHAUST GASES.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 5 June 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Deck/Cargo
Issued 5 June 1997 Resolved
CARGO DECK SPRINKLER SYSTEM HAD SEVERAL CLOGGED NOZZLES AND INSUFFICIENT FIRE MAIN PRESSURE.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 5 June 1997 Resolved
CREW COULD NOT PROPERLY CALIBRATE PORTABLE OXYGEN & GAS DETECTION ANALYZERSDURING EXAMINATION.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 12 April 1996 Resolved
PROVE PROPER OPERATION OF CARGO DECK SPRINKLER SYSTEM TO COAST GUARD INSPECTOR PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 13 April 1996
Resolved 13 April 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.