MAURY USCG vessel records Sign in
← All vessels

MOZU ARROW

MOZU ARROW is a 1992 freight ship. The Coast Guard has recorded 23 inspections since 1992, most recently in December 2023, along with 11 deficiencies.

Records from 1992 to 2023. Most recent: inspection, 18 December 2023.

Built
1992
Last inspected
18 December 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8918227 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
378885
Flag
NORWAY
—
Maury page id
psix-378885

Inspections, by type

…with no type recorded10
Years with a record 17 calendar years (1992–2023)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28157 - Convention (Subpart B), Gross Ton
8841 - Convention (Subpart B), Net Ton
41007 - Dead Weight, Metric Ton
53291 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

18 December 2023 PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7838736
12 April 2021 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7168408
19 March 2021 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7159060
16 March 2021 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7154039
7 September 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7052527
24 August 2020 Ballast Water Examination · PSC A · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7041469
11 April 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6117717
9 October 2014 Ballast Water Examination · Administrative Inspection · ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5001988
25 October 2010 Administrative Inspection · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3877100
14 March 2009 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3433255
5 November 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3357542
28 May 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3213850
27 July 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2726438
28 January 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 286439
1 December 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 435435
19 June 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 416608
17 March 1997 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 401567
12 March 1996 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 388732
15 April 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 377328
15 December 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 363088
12 September 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 361125
13 November 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 354336
18 October 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 473144

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 March 2021 Resolved
Doors fited in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and self closing. Fire door from steering gear room to engine roomand another fire door in the bottom deck of the engine room were observed with cracks and unable to close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 12 April 2021
Resolution: RECEIVED CLASS REPORT VERIFYING DEFICIENCY CORRECTION.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 March 2021 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Purifier control panel was observed missing control covers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 12 April 2021
Resolution: RECEIVED CLASS REPORT VERIFYING DEFICIENCY CORRECTION.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 March 2021 Resolved
In a ship in which oil fuel is used the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and personel. Fuel oil drain was blocked causing fuel to flow on deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 12 April 2021
Resolution: RECEIVED CLASS REPORT VERIFYING DEFICIENCY CORRECTION.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 16 March 2021 Resolved
After any survey of the ship under paragraph 1 has been completed no changes shall be made without the permission of administration. Observed a leak on oily water separator discharge. Leak happened while PSCO was there.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2021
Resolution: RECEIVED CLASS REPORT VERIFYING DEFICIENCY CORRECTION.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 March 2021 Resolved
Instructions for onboard maintenance of life saving appliances complying with the requirements of regulation 52 shall be provided and maintenance shall be carried out accordingly. Hydrostatic release unit for EPIRB was found expired by 3 weeks.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2021
Resolution: RECEIVED CLASS REPORT VERIFYING DEFICIENCY CORRECTION.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2021 Resolved
Condition of ship and all equipment shall be maintained to conform with provisions of present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons. Temporary repair to ballast line portside before forward bulkhead. Also ship modified bilgeline from cargio hold to draininto engine room.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2021
Resolution: RECEIVED CLASS REPORT VERIFYING DEFICIENCY CORRECTION.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 August 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will ramain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a in set in the port bow and markings along the port side of the hull from a reportable marine casualty. PSCO determined class is needed to ascertain the vessels seaworthiness and the condition of the ships structural integrity in order to determine the ship meets the criteria to safely transit with crew members on board. SOLAS 74(2014) Chp.1 Reg. 11 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Survey Statement; Vessel will have issue repaired prior to October 27th, 2020.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 October 2014 Resolved
MARPOL (Cons. 2011) Annex I, Reg. 14.2 Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with alarm arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the affluent exceeds 15 ppm. The OWS content meter is not capable of automatically stopping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2014
Resolution: 28OCT14: Inspection team went onboard M/V MOZU ARROW to review Class Survey report for newly installed OWS parts. Ensured test carried out and all sat.
Construction/Loadline
Issued 19 June 1998 Resolved
The portable drainage containment 35-gallon tank was not per the original installation IAW 1974 SOLAS II-1.29.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Fire Fighting
Issued 19 June 1998 Resolved
The emergency fire pump suctioning piping was not enclosed in substantial steel casing IAW 1974 SOLAS II-2.4.6.3.
Condition: Unknown
Due 15 October 1998
Resolved 30 September 1998
Lifesaving
Issued 19 June 1998 Resolved
The steering gear room had no arrangement around the steering gear; i.e. handrails, grating or non-slip surface IAW 1974 SOLAS II-1.29.13.2.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998

Ownership record