MAURY USCG vessel records Sign in
← All vessels

LOUISE

LOUISE is a 1988 tank ship. The Coast Guard has recorded 14 inspections since 1992, most recently in May 2005, along with 5 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 1992 to 2005. Most recent: inspection, 26 May 2005.

Built
1988
Last inspected
26 May 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8706820 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
378886
Flag
LIBERIA
—
Maury page id
psix-378886

Inspections, by type

…with no type recorded10
…past their stated due date1
Years with a record 8 calendar years (1992–2005)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29998 - Dead Weight, Ton
19925 - Convention (Subpart B), Gross Ton
19925 - Regulatory (Subpart C or D), Gross Ton
8017 - Convention (Subpart B), Net Ton
8017 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

26 May 2005 COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2368534
22 August 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1883742
6 November 2002 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1702081
6 September 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 407619
2 April 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 483602
18 September 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 450640
2 March 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 687775
21 February 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 480746
20 February 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 468751
20 February 1994 Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 853461
18 April 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 496935
18 April 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1150037
16 August 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 538100
16 August 1992 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 960010

Deficiency record · 5

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 26 May 2005 Resolved
None of the remote emergency cargo pump shutdown devices function on board this vessel when tested during a routine COC exam. These shall all be proven to be fully operational to an attending ABS surveyor prior to the vessel conducting cargo operations in U.S. waters.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 27 May 2005
Resolution: Received a written report from ABS that states that the system has been overhauled by shore side personnel and is now fully operational. This deficiency is cleared based on this class report this date.
Navigation › Collision/Grounding Avoidance
Issued 24 August 2003 No resolution recorded
Requested Letter of Deviation (departure) for inopertative secondary marine radar. LEGACY COMPONENT DESC: Radar
Due 24 August 2003 — due date passed with no resolution recorded
Resolution: Your request for deviation from the provision of 33 Code of Federal Regulations (CFR) 164.37(a) is granted only for departing the Port of Guayanilla and shall expire immediately upon leaving the San Juan Captain of the Port Zone.
Navigation › Collision/Grounding Avoidance
Issued 22 August 2003 Resolved
Requested Letter of Deviation (arrival) for inopertative secondary marine radar. LEGACY COMPONENT DESC: Radar
Due 22 August 2003
Resolved 22 August 2003
Resolution: Your request for deviation from the provision of 33 Code of Federal Regulations (CFR) 164.37 is granted only for entering the Port of Guayanilla and shall expire immediately upon arriving at Peerless Chemicals.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 6 November 2002 Resolved
Found vessel's sewerage system lined up for overboard discharge vs. the required 100% retention while inside of 3NM. Had crew correct misalignment on the spot, also found MSD not treated with CL tablets, also corrected on the spot.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 6 November 2002
Resolution: Issued Letter Of Warning to ship''s master and notified Liberian consulate of same.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 6 November 2002 Resolved
Found all ballast tank vent flame screens in severe states of disrepair and must be corrected prior to departing the port of NY to satisfaction of USCG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 7 November 2002
Resolution: Based on a signed and stamped affidavit from ship''s master, this item was cleared and no longer remains outstanding. Master''s Indian license # IFOO-5304 was referenced with this affidavit and master has been advised that this item will be followed up on

Ownership record