BLUE SAPPHIRE
Freight Ship · Bulk Carrier class · Built 2000s · USCG Northwest District (CGD-NW) · Other hulls named BLUE SAPPHIRE
BLUE SAPPHIRE is a 2001 freight ship. The Coast Guard has recorded 13 inspections since 2002, most recently in February 2012, along with 4 deficiencies and 4 operational controls.
Records from 2002 to 2012. Most recent: inspection, 2 February 2012.
- Built
- 2001
- Last inspected
- 2 February 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9226671 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7VB7
37891
Flag
MARSHALL ISLANDS
—
Maury page id
psix-37891
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it28085 - Convention (Subpart B), Gross Ton
16065 - Convention (Subpart B), Net Ton
48907 - Dead Weight, Ton
57340 - Displacement, Ton
16065 - Convention (Subpart B), Net Ton
48907 - Dead Weight, Ton
57340 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
2 February 2012
Deficiency Check · PI Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4226001
25 January 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4244448
7 December 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4203866
7 December 2011
PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4204051
1 December 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4197728
7 December 2009
PII Safety Exam · MARPOL Annex VI Survey · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3643225
18 April 2008
Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3181288
11 November 2007
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3097720
12 March 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2885631
10 January 2006
Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS I Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2563645
8 July 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2127540
4 November 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1700987
30 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1698719
Deficiency record · 4
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 December 2011
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Electrical junction box for the steering gear fan was not water/weather tight.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 1 December 2011
Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range and density or particle size, or other phenomena associated with incipient fires to with the detector is designed to respond. See attached
Lifesaving › Inflatable Liferafts › Container Construction
Issued 1 December 2011
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Forward liferaft container found cracked, possibly exposing liferaft to the outside elements.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 11 November 2007
Resolved
Make permanent repairs to main engine, cylinder #4, apparent broken piston rings, prior to departure and provide a class report..
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National