Inspection history · 25
7 July 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8167856
14 November 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8031594
15 July 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7958625
7 February 2024
Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7846386
10 January 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7847829
17 July 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7744613
9 May 2023
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684811
7 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605730
6 August 2022
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7530953
18 July 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7507627
1 December 2021
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7358956
3 September 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7306143
6 August 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7283580
8 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7247205
7 July 2020
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6992822
16 January 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6889437
25 October 2019
Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6842270
20 September 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6816953
8 July 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6741465
27 April 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6675253
2 July 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6464018
6 February 2018
Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6350280
11 October 2017
Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6296274
18 July 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6209283
16 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5938428
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 July 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB battery is expired. Vessel's route is restricted to lakes, bays and sounds until valid battery is installed. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2025
Resolved 5 September 2025
Resolution: Operator emailed photo of EPIRB with new battery installed onboard. Photo uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2025
Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members... The port side stanchion supporting the galley house structure exhibited a crack through the paint around the post where it is welded to the base plate. Remove paint from the area to allow inspection of base plate weld integrity. 46 CFR 176.610(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 17 July 2025
Resolution: MI attended vessel and cracked paint had been removed. Verified satisfactory stanchion integrity.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 7 July 2025
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Throttle cable penetration from
captain's quarters to engine room is not vapor tight. 46 CFR 177.405(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 17 July 2025
Resolution: MI attended vessel and observed satisfactory correction.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 7 July 2025
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Employee assistance program hotline information was not displayed onboard. 46 CFR 16.401(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 17 July 2025
Resolution: MI attended vessel and observed hotline number posted in crew area.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 July 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Multiple items of the onboard first aid kit are expired. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 17 July 2025
Resolution: MI attended vessel and observed expired items were replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 July 2025
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The onboard Preventative Maintenance Plan was 1) missing updates to the Inventory of Rigging Components and 2) lacked recent documentation of examination and maintenance. 46 CFR 176.800(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 17 July 2025
Resolution: MI attended vessel and observed satisfactory updates to rig inventory and updated rig inspection logs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2024
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. MI observed 01 child lifejacket without light, operator installed with spare.
46 CFR 180.75(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 July 2024
Resolution: Operator installed new light on lifejacket.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 July 2024
Resolved
Each survival craft must be: secured to the vessel by a painter with a float-free link permanently attached to the vessel. MI observed float free-link attached incorrectly, operator fixed and installed correctly.
46 CFR 180.130
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2024
Resolution: Operator installed float free-link correctly to MI satisfaction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 January 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The vessel has not completed a drydock examination within the last two years. Conduct satisfactory drydock examination prior to the carriage of passengers.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2024
Resolution: Completed satisfactory drydock exam on 07FEB2024.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 July 2023
Resolved
AT EACH INSPECTION FOR CERTIFICATION AND AT EVERY OTHER VESSEL INSPECTION ALL UNSAFE PRACTICES, FIRE HAZARDS, AND OTHER HAZARDOUS SITUATION MUST BE CORRECTED AND ALL REQUIRED GUARDS AND PROTETIVE DEVICES MUST BE IN SATISFACTORY ORDER. GALLY TABLE ELECTRICAL OUTLET COVER BROKEN WITH EXPOSED WIRES, REQUIRES REPLACEMENT.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 21 August 2023
Resolution: Replaced outlet cover with brand new one.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 July 2023
Resolved
EVERY VESSEL MUST HAVE DETAILED INSPECTION OF THE RADIO INSTALLATION BY AN FCC-LICENSEND TECHNICIAN EVERY FIVE YEARS. VESSEL'S CERTIFICATE HAS EXPIRED, AND DUE TO ROUTE EXCEEEDING 20 NM, REQUIRES A MF RADIO WHICH MUST BE VERIFIED ON THE CERTIFICATE.
47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 12 January 2024
Resolution: Vessel provided new inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 July 2023
Resolved
VESSELS MUST SUBMIT PLANS TO THE COGNIZANT OCMI FOR THE INSTALLATION AND USE OF MONITORING DEVICE TO ENSURE THE WAKEFULNESS OF THE WATCHMEN. SUBMIT PLANS TO OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 25 January 2024
Resolution: Completed plan review, ops check, and visual inspection of all wiring.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 July 2023
Resolved
VESSELS DESCRIBED BY 46 CFR 175.110(c)MUST HAVE AN INTERCONNECTED FIRE DETECTION SYSTEM IN COMPLIANCE WITH 181.450 INSTALLED IN ALL ENCLOSED AREAS WHERE PASSANGERS AND CREW HAVE ROUTINE ACCESS, INCLUDING ACCOMODATION SPACES AND MACHINERY SPACES. VESSEL MUST SUBMIT SMOKE DETECTION PLAN FOR [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 25 January 2024
Resolution: Completed plan review, ops check, and visual inspection of detectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2023
Resolved
PROPULSION MACHINERY MUST BE SUITABLE IN THE TYPE AND DESIGN FOR PROPULSION REQUIREMENTS OF THE HULL IN WHICH IT IS INSTALLED AND CAPABLE OF OPERATING AT CONSTANT MARINE LOAD UNDER SUCH REQUIREMENTS WITHOUT EXCEEDING ITS DESIGNED LIMITATIONS. VESSEL PREVENTIVE MAINTENANCE PLAN (PMP) DOES NOT INCLUDE DATES FOR UNSTEPPING MASTS AND REPLACING STANDING RIGGING AS REQUIRED IN NVIC 02-16. PROVIDE PROPOSAL FOR UNSTEPPING MASTS FOR INSPECTION BY ATTENDING MARINE INSPECTOR AND REPLACING STANDING RIGGING ON A SCHEDULE THAT COMPLIES WITH NVIC 02-16 OR PROVIDES EQUIVALENT MARGIN OF SAFETY AS APPROVED BY [name withheld] IS APPROVED, RESUBMIT PMP WITH NEW TIMELINES.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 16 January 2024
Resolution: Vessel provided PMP with correct information with dates for maintenance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2023
Resolved
PROPULSION MACHINERY MUST BE SUITABLE IN TYPE AND DESIGN FOR PROPULSION REQUIREMENTS OF THE HULL IN WHICH IT IS INSTALLED AND CAPABLE OF OPERATING AT CONSTANT MARINE LOAD UNDER SUCH REQUIREMENTS WITHOUT EXCEEDING ITS DESIGNED LIMITATIONS. MARINE INSPECTOR FOUND FORESTAY TURNBUCKLE MISSING COTTER PINS. CREW REPLACED BEFORE END OF INSPECTION.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2023
Resolved 31 July 2023
Resolution: Replaced missing cotter pin
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 18 July 2022
Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Permanent watertight coamings must be provided as follows: a vessel on an exposed route, a watertight coaming with a height of at least 150mm (6 inches) must be provided. Vessels current coaming is not a permanent installation as required. To be rectified by the next dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 23 April 2024
Resolution: Verified means of providing a coaming height of at least 6 inches.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 July 2021
Resolved
"Survival craft must be secured to the vessel by a painter."
46 CFR 180.130(a)
Painter was not secured. Fixed on the spot during inspection.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2021
Resolved 8 July 2021
Resolution: Secured painter during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
"The design, and standing rigging on a sailing vessel must be suitable for the intended service." 46 CFR 177.330
Loose bolts, tighten for serviceability.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 July 2021
Resolved 8 July 2021
Resolution: Tightend bolts during inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 July 2021
Resolved
"All mattresses must comply with 16 CFR part 1632. 46 CFR 177.405 Currently installed mattresses are not fire rated. Resolve prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Resolved 25 January 2024
Resolution: Vessel replaced all mattresses with appropriate fire rated ones.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 July 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. The eye cleaning solution was expired.
46 CFR 184.710
Action required: 10 - Deficiency Rectified
Due 7 July 2020
Resolved 7 July 2020
Resolution: Operator replaced the expired eye wash.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 September 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck. Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered automatically operated lights in strategic locations. These lights shall have an automatic battery charger, shall not be readily portable and shall have sufficient capacity for 6 hours of continuous operation. Vessel did not have emergency lighting. Install IAW 46 CFR 184.30-5. Vessel is restricted in their ability to carry overnight passengers until the deficiency is rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2019
Resolved 9 March 2020
Resolution: Emergency lighting circuit installed, tested and plan reviewed IAW 46CFR.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2019
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear". Vessel was missing labeling on the external portion of the forward most emergency exit. Label IAW 46 CFR 185.30-15.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 14 February 2020
Resolution: Recieved photos of newly installed placards.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 July 2019
Resolved
46 CFR 176.25-5 - In sailing vessel's the Marine Inspector shall inspect all spars, standing rigging, running rigging, blocks, fittings and sails. Vessel's forward pin rail struts, both port and starboard side, are cracking. Replace or repair struts and prove proper operation to the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 5 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 July 2019
Resolved
46 CFR 176.25-5 - Inspect all railings and bulwarks and their attachments to the hull structure. Railing adjacent to the vessel's starboard embarkation area is cracked. Replace or repair rail to the satisfaction of the attending Marine Inspector prior to next credit dry dock.
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 18 October 2019
Resolution: Operator sent picture of the replaced railing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2019
Resolved
The selection of crew members for random drug testing shall be made by a scientifically valid method, such as a random number table or a computer-based random number generator that is matched with the crewmembers' social security numbers, payroll identification number or other identifying numbers. Vessel hasn't used a scientifically based method to conduct random selection of chemical testing. Establish an appropriate random selection process and notify the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2019
Resolved 25 July 2019
Resolution: Operator proved proper method of random testing.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 2 July 2018
Resolved
Obtain valid FCC safety certificate (including CHF and SSB).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2018
Resolved 2 November 2019