← All vessels
SWIFT ARROW
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named SWIFT ARROW
SWIFT ARROW is a 1992 freight ship. The Coast Guard has recorded 26 inspections since 1993, most recently in May 2020, along with 5 deficiencies and 2 operational controls.
Records from 1993 to 2020. Most recent: inspection, 13 May 2020.
- Built
- 1992
- Last inspected
- 13 May 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8918239 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6N17
379137
Flag
NORWAY
—
Maury page id
psix-379137
Inspections, by type
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28157 - Convention (Subpart B), Gross Ton
8841 - Convention (Subpart B), Net Ton
42276 - Dead Weight, Ton
53335 - Displacement, Ton
8841 - Convention (Subpart B), Net Ton
42276 - Dead Weight, Ton
53335 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
13 May 2020
PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6950773
31 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6297603
20 May 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5881786
12 March 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4811857
3 September 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4130580
17 December 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3910970
23 March 2009
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3438252
2 August 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3287191
19 July 2008
Ballast Water Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3269979
20 March 2008
ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3166361
20 March 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3171183
15 November 2007
Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3095538
11 November 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3096677
6 April 2007
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2909011
4 April 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2901801
3 April 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2900902
1 April 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2899237
24 September 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 282429
28 July 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 431137
12 May 1997
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 403550
28 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 391628
1 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 452765
15 September 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 382747
30 August 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 369994
30 August 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1179418
2 August 1993
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 362170
Deficiency record · 5
Fire Fighting › International Shore Connection › Washers
Issued 26 May 2016
Resolved
The International shore connection shall contain 08 washers. The connection contained only 04.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 May 2016
Resolved
The condition of the ship and its equipment shall be maintained to the conform with the provisions of the present regs. Incinerator's electrical lighting system is not functioning properly.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 September 2011
Resolved
1730, Oil Separating Equipment, any ship of 10,000 GT shall be fitted with oil filtering equipment. The system shall also be fitted with arrangement to ensure that any discharge of oily mixtures is automatically stopped when the oil content exceeds 15 ppm. Oil content meter sensing unit is not operational due to a broken sensor window. Marpol 73/78 Annex I regulation 14. 15a.
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2008
Resolved
During inbound transit to Jacksonville vessel reported possible grounding. PSCO verified sounding of all tanks. Request that class provide report attesting to vessels seaworthiness prior to departure.
Construction/Loadline › Hull › Bottom Plating
Issued 1 April 2007
Resolved
Vessel sustained damage during a grounding incident in Brazil. Vessel is going to dry dock after leaving the Port of Tampa.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.