MAURY USCG vessel records Sign in
← All vessels

AO 105

AO 105 is a 1992 tank barge. The Coast Guard has recorded 47 inspections since 1992, most recently in April 2021, along with 6 deficiencies and 1 casualty investigation in 2011.

Records from 1992 to 2021. Most recent: inspection, 27 April 2021.

Built
1992
Last inspected
27 April 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

379354
Flag
UNITED STATES
—
Maury page id
psix-379354

Inspections, by type

…with no type recorded8
Years with a record 30 calendar years (1992–2021)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it705 - Simplified, Gross Ton
705 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 47

27 April 2021 Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7185326
3 January 2020 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6889788
16 April 2019 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6664542
23 March 2018 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6378776
12 January 2017 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6071776
9 March 2016 COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5829789
1 June 2015 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5142436
25 February 2015 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5074642
20 May 2014 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4863329
7 August 2013 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4677972
3 July 2012 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4367827
11 May 2012 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4310787
26 April 2012 Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4298573
1 July 2011 MTSA Verification · Cargo Tank Internal · COI Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4064453
28 April 2010 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3726320
22 June 2009 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3511041
30 April 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3195795
4 June 2007 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2951992
24 July 2006 COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2723354
7 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2619395
9 August 2005 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2456566
4 August 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2450954
25 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2319387
22 March 2005 MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2316976
28 February 2005 MTSA Verification · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2300592
10 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238506
14 September 2004 Drydock Extension
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2195275
3 May 2004 Periodic Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2058305
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1983825
18 August 2003 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1886538
4 June 2003 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1809764
17 April 2002 Hull Examination · Cargo Tank Internal · Internal Structural Exam · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1495085
2 August 2001 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1458905
15 August 2000 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 821158
7 September 1999 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1384243
13 October 1998 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 801721
22 October 1997 COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1418257
12 August 1996 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1418005
20 July 1995 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1192958
8 September 1994 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 866924
22 November 1993 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 467556
13 October 1993 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1142711
2 August 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 642142
18 June 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 55767
18 June 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 216350
14 October 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 479414
29 September 1992 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 948194

Deficiency record · 6

04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 January 2020 Resolved
The emergency shutdown for the pump engine did not properly shut the engine down.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 15 January 2020
Resolution: The seal that engages to block the flow of air had carbon buildup allowing air to pass through even after it was actuated. Cleaned seal and tested emergency stop. Emergency stop performed as required.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 March 2018 Resolved
The emergency shutdown was not working as intended. Potentially due to the closure device being frozen in the open position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 23 March 2018
Resolution: Witnessed proper operation of emergency shutdown of the barge engine.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 12 January 2017 Resolved
Cargo pump engine stuck in high throttle and could not be adjusted. Had to pull emergency shutdown to stop the engine. Prior to conducting discharge operations, show proper operation of the cargo pump engine to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2017
Resolved 17 January 2017
Resolution: Attended vessel and witnessed proper operation of cargo pump engine.
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2012 Resolved
Make permanent repairs to pinhole IWO the starboard stern corner wrapper approx 12" above the bottom plate and 12" fwd of stern plate.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2012
Resolution: Fracture in starboard stern corner wrapper gouged, welded and air tested sat.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 14 September 2004 Resolved
FOUND EMERGENCY SHUTDOWN CABLE PARTED AND INOPERABLE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 September 2004
Resolved 14 September 2004
Resolution: CORRECTED.
Lifesaving
Issued 2 August 2001 Resolved
STENCIL "DANGER KEEP OUT" ON ALL BUTTERWORTH OPENINGS.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001

Casualty record · 1

27 April 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3997160
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.