MAURY USCG vessel records Sign in
← All vessels

EMERALD PARK

EMERALD PARK is a 1992 tank ship. The Coast Guard has recorded 61 inspections since 1992, most recently in October 2007, along with 22 deficiencies and 1 operational control.

Records from 1992 to 2007. Most recent: inspection, 5 October 2007.

Built
1992
Last inspected
5 October 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9031507 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
379565
Flag
UNITED KINGDOM
—
Maury page id
psix-379565

Inspections, by type

…with no type recorded46
Years with a record 12 calendar years (1992–2007)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9103 - Dead Weight, Ton
4989 - Simplified, Gross Ton
4989 - Convention (Subpart B), Gross Ton
2747 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 61

5 October 2007 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3077491
22 September 2007 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3063562
25 August 2006 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2759539
25 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2759633
27 April 2001 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 289576
5 September 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 281623
5 September 2000 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1361715
15 July 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 430829
25 June 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 430126
25 June 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1078814
24 June 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 429957
30 March 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 39604
9 February 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425406
5 September 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 181914
13 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417962
13 July 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 794684
4 May 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 415106
29 October 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409444
17 August 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 406845
2 June 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 404111
12 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 36935
19 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395488
11 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395318
9 August 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394057
9 August 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1086513
28 May 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 391584
28 May 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 701997
22 February 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 438253
29 January 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 22318
6 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182647
6 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 384678
4 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 19202
4 November 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 384584
4 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 381293
4 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1187295
3 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379161
14 February 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 456440
13 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866261
4 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 370204
25 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 865367
8 August 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 369453
8 August 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389896
11 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 478951
20 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367011
20 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 860064
5 April 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 459946
16 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493248
8 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 657029
30 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 20328
27 October 1993 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1143080
6 October 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 651870
4 October 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464477
21 September 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1151314
4 September 1993 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 827032
4 September 1993 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1140206
3 September 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 831436
22 March 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 836538
28 January 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 538651
6 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355556
3 December 1992 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1141966
2 September 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 953620

Deficiency record · 22

Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 22 September 2007 Resolved
VCS did not have fixed bolt on flange. Vessel is not to conduct cargo operations that require the use of VCS in the US until deficiency is rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 5 October 2007
Resolution: Received proper documentation satisfying requirement.
Deck/Cargo
Issued 25 June 1999 Resolved
INSTALL STUD ON PORT SIDE VCS CONNECTION FLANGE PRIOR TO LOADING CARGOES REQUIRING VCS IN U.S. WATERS.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Fire Fighting
Issued 24 June 1999 Resolved
Portable fire extinguishers have not been tested and re-certified by a licensed, professional fire inspection Company as required by SOLAS 74 II-2Regulation 6.5. Vessel documentation indicate last certification/inspectionwas done in May, 1997. Class Society specifies time-period of inspections.
Condition: Unknown
Due 3 July 1999
Resolved 3 July 1999
Deck/Cargo
Issued 9 August 1996 Resolved
Prior to loading cargo, pressure test P/V valves as per 33 CFR 155.170._x001C_ Provide documentation to local Coast Guard prior to loading cargo.
Condition: Unknown
Due 9 August 1996
Resolved 12 August 1996
Lifesaving
Issued 9 August 1996 Resolved
Provide copy of Unitor servicing report for EEBA's to local Coast Guard, asper IBC 14.2
Condition: Unknown
Due 9 August 1996
Resolved 12 August 1996
Deck/Cargo
Issued 9 August 1996 Resolved
Provide drain at low points on Vapor Recovery (VCS) crossheader pipeline_x001C_ as per 46 CFR 39.20-1. VCS not to be used for closed loading on incompatibile cargoes unless header is inspected & cleaned.
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Navigation
Issued 28 May 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Navigation
Issued 8 August 1994 Resolved
IAW SOLAS, Chapter II-1, Regulation 29/13.2, a non-slip surface is requiredin the steering gear compartment.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Engineering
Issued 8 August 1994 Resolved
IAW SOLAS Chapter II-2, Part D, Flame Screens were missing from F/O and L/Ovents.
Condition: Unknown
Due 10 August 1994
Resolved 24 August 1994
Navigation
Issued 8 August 1994 Resolved
The vessel's steering gear was not operating properly.
Condition: Unknown
Due 10 August 1994
Resolved 24 August 1994
Accommodation/Occupational Safety
Issued 8 August 1994 Resolved
In violation with ILO 147 Convention, the crew's laundry was found to be hanging in open passageways, in varying states of cleanliness.
Condition: Unknown
Due 10 August 1994
Resolved 24 August 1994
Navigation
Issued 8 August 1994 Resolved
The Port Turning Circle Diagram for a 90 degree turn was missing on the fact sheet.
Condition: Unknown
Due 8 August 1994
Resolved 24 August 1994
Navigation
Issued 8 August 1994 Resolved
The Table of Speeds (at which the Bow Thruster is effective) was missing from the maneuvering fact sheet.
Condition: Unknown
Due 8 August 1994
Resolved 24 August 1994
Deck/Cargo
Issued 21 September 1993 Resolved
TEST VESSEL'S CARGO PIPING TO 1.5 TIMES M.A.W.P.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Navigation
Issued 21 September 1993 Resolved
POST BLOCK DIAGRAM SHOWING CHANGE OVER PROCEDURES FOR EMERGENCY STEERING ONBRIDGE.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Navigation
Issued 21 September 1993 Resolved
PROVIDE A TABLE OF SPEEDS AT WHICH BOW THRUSTER IS EFFECTIVE ON MANUEVERING FACT SHEET.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 21 September 1993 Resolved
PROVIDE CARGO HOSES WITH REQUIRED MARKINGS AS PER 46 CFR 153.940.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 21 September 1993 Resolved
PROVIDE GRAPH OR TABLE INDICATING PRESSURE DROP THROUGH VAPOUR COLLECTION SYSTEM. MUST BE FROM VESSEL'S MOST REMOTE CARGO TANK; PRESENT CALCULATIONSINDICATE CARGO TANK #2 PCS.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Documentation
Issued 21 September 1993 Resolved
PROVIDE TABLE OR GRAPH IN THE VESSEL'S OIL TRANSFER PROCEDURES SHOWING THE LIQUID TRANSFER RATE VERSUS THE PRESSURE DROP.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 21 September 1993 Resolved
VESSEL VAPOR CONNECTION FLANGES, PORT AND STBD MUST BE PROVIDED WITH A PERMANENTLY ATTACHED 0.5 INCH DIAMETER STUD AT LEAST 1 INCH LONG FROM THE FLANGE FACE, AT THE TOP OF THE FLANGE IN LIEU OF THE BOTTOM.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Deck/Cargo
Issued 21 September 1993 Resolved
TEST VESSEL'S CARGO HOSES WHICH ARE REQUIRED TO BE TESTED ANNUALLY.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 2 September 1992 Resolved
PROIR TO USING THE UCS PROVIDE CLASS SOCIETY CERTS SHOWING THE SYSTEM MEETS46CFR39 AND 33CFR154.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.