MAURY USCG vessel records Sign in
← All vessels

MARIANAO ICE

MARIANAO ICE is a 1991 freight ship. The Coast Guard has recorded 47 inspections since 1992, most recently in March 2010, along with 24 deficiencies — 1 with no resolution recorded — and 15 operational controls.

Records from 1992 to 2010. Most recent: inspection, 24 March 2010.

Built
1991
Last inspected
24 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8509569 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
379657
Flag
MALTA
—
Maury page id
psix-379657

Inspections, by type

…with no type recorded19
Years with a record 13 calendar years (1992–2010)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it6232 - Dead Weight, Ton
10840 - Displacement, Ton
7389 - Convention (Subpart B), Gross Ton
2754 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 47

24 March 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3701093
3 February 2010 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3675050
13 January 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3663522
13 January 2010 PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3663529
11 January 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3662105
5 December 2009 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3645140
14 July 2009 NPV Safety Exam · MARPOL Annex I Examination · MARPOL Annex VI Survey · ISPS I Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3530229
27 April 2009 ISPS I Exam · COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3459188
10 April 2009 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3448268
23 March 2009 COE-Offshore · ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3438705
4 March 2009 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3424574
5 February 2009 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3412322
15 January 2009 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3394693
27 December 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS I Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3384113
13 November 2008 ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3362668
13 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3362786
31 October 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3354961
31 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3354989
23 October 2008 MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3347546
21 October 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3348757
3 October 2008 ISPS I Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3334804
29 September 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3334796
27 August 2008 PII Safety Exam · Ballast Water Examination · ISPS I Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3300079
30 July 2008 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3276989
11 July 2008 ILO-147 Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3264747
9 July 2008 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3260767
5 June 2008 ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3227950
26 October 2007 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3087818
23 October 2007 MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3085239
15 September 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3058086
6 April 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2903213
30 January 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2798677
7 October 2004 NPV Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2215609
13 June 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1821589
12 November 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1704190
22 October 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1694447
30 March 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 414080
30 December 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 520239
11 March 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 401068
23 January 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 399595
24 November 1995 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 384981
15 February 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 509110
12 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 369307
12 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 688174
12 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 864720
19 April 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 478903
2 September 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353038

Deficiency record · 24

Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 January 2010 No resolution recorded
OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL ITEMS OUTLINED IN POLLUTION PREVENTION REGULATIONS SUCH AS MEANS OF COMMUNICATION.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Sea-water System (primary cooling) › Pump
Issued 23 October 2008 Resolved
Generator cooling pump number 3 removed by ships crew. Generator cooling pump number 2 discharge pipe removed by ships crew. No suitable standby pump available if number 1 fails. PSCO witnessed generator operating temperatures within normal manufacturer operating range, however temperature may increase during cargo operations.
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 31 October 2008
Resolution: Received class report from GL satisfying requirement.
Navigation › Piloting/Steering › Gyro Compass
Issued 23 October 2008 Resolved
Vessel reported inop gyro compas and was granted deviation to enter. Provide technicians report attesting to proper operation prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2008
Resolved 31 October 2008
Resolution: Received class report from GL satisfying requirement.
Engineering › Fuel Oil Service System › Piping
Issued 27 August 2008 Resolved
The no.5 cylinder high pressure fuel oil lines for the main diesel engine are leaking fuel oil.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 August 2008
Resolved 3 October 2008
Resolution: Germanischer Lloyd attended vessel and verified the leakage had stopped, and was inspected for satisfactory operation.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 August 2008 Resolved
The no.2 ship service diesel generator has a leak from the salt water cooling return line fitting.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 August 2008
Resolved 3 October 2008
Resolution: Attending class surveyor approved the permanent repair of the cooling line that had been cropped and replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 August 2008 Resolved
The no.3 ship service diesel generator has a band clamp patch on the salt water cooling inlet pipe.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 August 2008
Resolved 3 October 2008
Resolution: Attending class surveyor approved the repair of the cooling line that had been cropped and replaced.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 August 2008 Resolved
Tide and current publications are out of date.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2008
Resolved 3 October 2008
Resolution: vessel has onboard current tidal and current tables.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 27 August 2008 Resolved
Ground cable to port side crane winch was found disconnected from permanent connection.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 August 2008
Resolved 3 October 2008
Resolution: Attending class surveyor observed and approved that the ground cable had been cleaned and properly made fast to deck.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 August 2008 Resolved
The vessel conducted the bunkering lines using air vice liquid as per 33 CFR 156.170.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 August 2008
Resolved 3 October 2008
Resolution: Observed that f/o and l/o piping had been properly hydrostatically tested.
Lifesaving › Launching Appliances › Winch Brake
Issued 23 October 2007 Resolved
The starboard side lifeboat davit system's gravity brake is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2007
Resolution: Received tech report attesting to the proper repairs of starboard side lifeboat davit brake.
Engineering › Diesel Engine (propulsion-electric) › Turbocharger
Issued 15 September 2007 Resolved
The vessel reported a loss of propulsion. Vessel is required to submit documentation from the certificate issuing authority attesting to the proper repair.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2007
Resolution: Received a report to class attesting to repair made on main propulsion.
Lifesaving › Launching Appliances › Winch Brake
Issued 7 October 2004 Resolved
Gravity brake not functioming properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2004
Resolution: Item cleared by class report
Pollution Prevention/Response › Prevention Equipment
Issued 22 October 2002 Resolved
Replace/Renew wasted sections of sewage piping located in overhead. Repairs to be completed to the satisfaction of attending USCG inspector. LEGACY COMPONENT DESC: Sewage System Piping
Condition: Improper/Lack of Maintenance
Due 22 November 2002
Resolved 13 November 2002
Resolution: Entire sewage piping has been replaced and is now in proper working order. Mr. A duncan seperintendant.
Fire Fighting › Means of Escape
Issued 22 October 2002 Resolved
Adjust all fire doors in engine room. Doors are not closing, self closing devices missing. Class to attest to repairs and provide report to USCG. LEGACY COMPONENT DESC: Doorways
Condition: Improper/Lack of Maintenance
Due 22 November 2002
Resolved 12 November 2002
Resolution: New self closing devices installed on engine room fire doors. The doors adjusted for proper self closing and tested satisfactory by class.
Lifesaving › Lifeboat
Issued 22 October 2002 Resolved
Port lifeboat has minor damage to hull and keel. Damage due to chaffing on davit. Class to address and attest to proper lifeboat/davit chaffing protection, including replacement of rubber stops on davit, Class to provide report to USCG. LEGACY COMPONENT DESC: Carriage Requirement
Condition: Improper/Lack of Maintenance
Due 22 November 2002
Resolved 12 November 2002
Resolution: Damaged areas on lifeboat repaired and painted. Small modification of embarkation platform carried out to prevent touching of lifeboat. Life boat stops on the davit replaced/ adjusted as nessessarily. Repairs surveyed and found sat by class.
Lifesaving
Issued 23 January 1997 Resolved
PRIOR TO DEPARTURE FROM PORT OF MOREHEAD CITY, NC DEMONSTRATE PROPER OPERATION OF LIMIT SWITCH OF PORTSIDE LIFE BOAT.
Condition: Unknown
Due 24 January 1997
Resolved 27 January 1997
Fire Fighting
Issued 23 January 1997 Resolved
PRIOR TO DEPARTURE FROM PORT OF MOREHEAD CITY, NC PROVIDE SATISFACTORY MASKFOR THE SECOND FIREMAN'S OUTFIT.
Condition: Unknown
Due 24 January 1997
Resolved 27 January 1997
Fire Fighting
Issued 23 January 1997 Resolved
PRIOR TO DEPARTURE FROM THE PORT OF MOREHEAD CITY, NC PROVIDE CLASS ATTESTATION THAT VSL IS IN COMPLIANCE WITH SOLAS 74, CHAP II-2,R 4.3.3(SUB.4).
Condition: Unknown
Due 24 January 1997
Resolved 27 January 1997
Fire Fighting
Issued 23 January 1997 Resolved
PRIOR TO RETURN NEXT US PORT, PROVIDE CLASS ATTESTATION THAT VESSEL IS IN COMPLIANCE WITH SOLAS 74, CHAP II, R-4.3.3.4.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Fire Fighting
Issued 23 January 1997 Resolved
PRIOR TO DEPARTURE PAINTOVER EXISTING INT'L SHORE CONNECTION STENCIL ON MAIN DECK (STENCIL IN WRONG LOCATION).
Condition: Unknown
Due 24 January 1997
Resolved 27 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997 Resolved
PRIOR TO RETURN NEXT US PORT PROVIDE IMO/FLAG STATE APPROVAL TO TYPE II M.S.D.
Condition: Unknown
Due 24 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 23 January 1997 Resolved
PRIOR TO RETURN NEXT US PORT PROVIDE CLASS SOCIETY ATTESTATION AS TO CONDITION OF FRACTURES LOCATED IN WAY OF PORT/STBD BULWARK FRAMING WERE MEETS MAIN DECK (MID SHIP 1/2 LENGTH).
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Engineering
Issued 23 January 1997 Resolved
PRIOR TO RETURN NEXT US PORT PROVIDE CLASS ATTESTATION AS TO ADEQUACY OF LIQUID STEEL PATCH ON FUEL OIL DAY TANK.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Navigation
Issued 12 August 1994 Resolved
The vessel was in violation of 33 CFR 164.33(a)(1)(i) when the only chart on board was a B.A. #2801. This chart is not of large enough scale for thearea navigated. The missing required charts were NOAA chart #11512 or the B.A. chart #2807
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.