OLD TIMER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1993, most recently in May 2026, along with 52 deficiencies — 1 with no resolution recorded —.

Records from 1993 to 2026. Most recent: inspection, 20 May 2026.

Built
1978
Last inspected
20 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

379663
Flag
UNITED STATES
—
Maury page id
psix-379663

Inspections, by type

…past their stated due date1
Years with a record 28 calendar years (1993–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

20 May 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8385613
20 June 2025 DAPI Audit · COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8172167
22 October 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8023544
25 June 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7946739
25 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7709792
20 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7448687
18 May 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7215534
6 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7072376
29 July 2020 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7019621
19 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6963721
18 July 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6754607
27 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685882
27 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6402830
27 April 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6134123
5 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5863788
6 June 2012 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4331357
17 May 2012 Annual Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4306691
14 May 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3191583
26 July 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3008347
25 April 2007 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2911135
20 April 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2621598
5 May 2005 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2339245
29 April 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2049167
1 May 2003 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1779426
2 May 2002 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1608864
4 May 2001 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1470610
5 May 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1373059
6 July 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1089260
6 May 1999 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 796280
7 May 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1128954
15 August 1997 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1119678
8 May 1997 Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115803
9 May 1996 Plan Review "T" Boat · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1088043
22 May 1995 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 871389
26 April 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414443
25 May 1994 Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1443471
11 May 1993 Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1415844

Deficiency record · 52

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 May 2026 No resolution recorded
Fire extinguishers were past due for servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2025 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed has extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. No vent closures were present. Operator is to show proof of vent closures and make readily available in the vicinity of the vent(s). [46CFR182.460(l)]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: Received photo evidence of vent closures.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Only one fire bucket on board. Require replacement of 02 missing fire buckets IAW above regulation. [46 CFR 181.610]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: Received photo evidence of replacements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is certified to carry 23 POB, only 20 adult life jackets on board. Vessel is restricted to carrying no more than 20 POB until missing 03 life jackets are replaced. [46 CFR 180.71(a)]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 24 July 2025
Resolution: Received photo evidence of replacements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2025 Resolved
At least one ring life buoy must be fitted with a lifeline...Each lifeline on a ring life buoy must: Have a breaking strength of at least 5 kilonewtons (1,124 pounds). Lifeline is fraying and falling apart with minimal handling; require replacement. [46 CFR 180.70(c)(5)]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 24 July 2025
Resolution: Received photo evidence of replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Cooling water intake hose only has single clamp. Provide proof of double clamp on cooling water intake. [46 CFR 182.410(d)(1)]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: Received photo evidence of repair.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 June 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. No portable lights on board. Owner/operator must provide proof of 02 portable lights in required spaces. [46 CFR 183.430]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: Received photo evidence of purchased lights.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 June 2025 Resolved
The master shall conduct sufficient drills to make sure that all crew members are familiar with their duties during abandoning ship, recovery of persons who have fallen overboard, and in case of a fire onboard the vessel. The training records for man overboard and firefighting were not present. Operator is to provide proof of training for abandoning ship, recovery of persons who have fallen overboard, and in case of a fire onboard the vessel. [46CFR185.520/185.524]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 24 July 2025
Resolution: Received photo evidence of records.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 June 2024 Resolved
The master shall conduct sufficient drills to make sure that all crew members are familiar with their duties during abandoning ship, recovery of persons who have fallen overboard, and in case of a fire onboard the vessel. The training records for man overboard and firefighting were not present. Operator is to provide proof of training for abandoning ship, recovery of persons who have fallen overboard, and in case of a fire onboard the vessel. 46CFR185.520/185.524
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 22 October 2024
Resolution: Rcvd email of drills.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 June 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of a fire, heavy weather, or man overboard conditions. No emergency check-off list was present on the vessel. Operator is to provide proof of development of emergency instructions and mounting at the operating station. 46CFR185-510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 22 October 2024
Resolution: Rcvd email showing emergency instructions posted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Vessel is missing a 2A fire extinguisher per the Table 181.500(b). Operator is to show proof of purchasing and installing the missing fire extinguisher. 46CFR181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 22 October 2024
Resolution: Rcvd email with photo of proper extinguishers onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 June 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. No life jacket donning placards were present. Operator is to acquire the appropriate life jacket donning placard for the life jackets onboard and post it for view of passengers. 46CFR185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 22 October 2024
Resolution: Rcvd email showing donning instructions onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2024 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. The port side bilge discharge pipe was identified as damaged due to being melted by the vessel’s exhaust pipe. Operator is to replace the damaged pipe. 46CFR182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 22 October 2024
Resolution: Rcvd email showing new bilge hose installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 May 2023 Resolved
46 CFR 176.801(a) - If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed and discuss all requirements with the owner, managing operator, or a representative thereof. Fractures were found in the following locations: In the web of the frame just below fuel tanks in the machinery compartment at centerline extending from the top of the 1st stringer web attachment port side to the top of the frame web. In the gusset weld attachment to the bottom of the gunnel and forward machinery space bulkhead just above the fuel oil shutoff valve on the port side. Full length of transverse weld seam in the forward machinery space bulkhead just below the fuel oil shut off valve port side. Fractures are to be repaired to satisfaction of attending marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2023
Resolution: Received photos of repairs from operator.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 May 2023 Resolved
46 CFR 182.460(l) - Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel is not equipped with ventilation closures. Provide means for closing supply / exhaust scoops for the machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 25 June 2024
Resolution: verified vent closures on board during 2024 inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 May 2023 Resolved
46 CFR 184.710 - A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. During the annual inspection, it was determined that the vessel is equipped with an "equivalent kit". The vessels first aid kit was not in a suitable watertight container, was not equipped with triangle bandages, and the analgesic meds / antiseptic preparations were expired. Provide a suitable watertight container and replace expired antiseptic preparations / analgesic medication.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 9 June 2023
Resolution: Received photos from operator.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 May 2023 Resolved
46 CFR 176.810(a)/(b)(iv) - At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel did not have record of required annual servicing for portable of fixed extinguishers. A qualified servicing facility must perform required inspections / tests, and evidence of such is to be provided to the MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 25 June 2024
Resolution: Verified servicing during 2024 inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 August 2020 Resolved
Within 30 days, to the satisfaction of the USCG renew fractured welds located at the adjoining bow and body where the structure meets the hull on the port and starboard side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 18 May 2021
Resolution: During the annual inspection conducted visual examination of remedy to affected area, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 August 2020 Resolved
Within 30 days, to the satisfaction of the USCG, prove the Clean Agent Fire Extinguishing System (Fireboy) underwent annual inspection, servicing and testing IAW NFPA 2001 by a qualified Fire Protection Service Technician.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 18 May 2021
Resolution: Verified annual inspection of Fire-Boy was conducted IAW NFPA standards during annual examination.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 June 2019 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with manufacturer's instructions. Xintex Fireboy requires that the system be maintained in accordance with NFPA 2001, which states, at least annually all systems shall be inspected and tested for proper operation by personnel qualified in the installation and testing of clean agent systems. The Xintex Fireboy onboard has not yet undergone an annual inspection. Have a qualified servicer conduct the appropriate servicing of the installed fire extinguishing system and notify the Marine Inspector upon completion.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 18 July 2019
Resolution: Received official statement from Owner/Operator that fire servicing had concluded, all sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 May 2017 Resolved
Vessel owner to provide servicing report for fixed/installed fire fighting system, including the alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2017
Resolved 19 May 2017
Resolution: Servicing report received.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2017 Resolved
Replace expired consumables in the first aid kit.
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 19 May 2017
Resolution: Receipt received for the contents of the first aid kit that were replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 4 May 2017 Resolved
Replace worn life-ring buoy and attached line.
Due 4 June 2017
Resolved 19 May 2017
Resolution: Vessel representative replaced life-ring buoy and line.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 4 May 2017 Resolved
Prove proper operation of fume (gasoline) detector located in the machinery space.
Due 4 June 2017
Resolved 19 May 2017
Resolution: Vessel representative replaced the fume detector in the machinery space with a new one.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 May 2017 Resolved
Post life-jacket donning placard.
Due 4 June 2017
Resolved 19 May 2017
Resolution: Vessel reprentative posted new life-jacket donning placard.
Engineering › Gasoline Engine (propulsion) › Oil Pan (4 cycle)
Issued 4 May 2017 Resolved
Install flame screens in the drip pans under the fuel filters.
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 19 May 2017
Resolution: Vessel representative provided pictures of newly installed screens in the drip pans.
Lifesaving › Lifebuoys › Serviceable
Issued 5 May 2016 Resolved
Life ring was sun damaged and un-servicable
Condition: Improper/Lack of Maintenance
Due 5 June 2016
Resolved 17 May 2016
Resolution: New life ring placed onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2012 Resolved
Provide first aid kit and place onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2012
Resolved 6 June 2012
Resolution: New first aid kit onboard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 May 2012 Resolved
Provide a life jacket donning placard and place onboard.
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 6 June 2012
Resolution: Life jacket donning placard onboard.
Construction/Loadline › Structures › Superstructure
Issued 17 May 2012 Resolved
Aft starboard hand rail stanchion broken. Make weld repairs to stanchion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2012
Resolved 6 June 2012
Resolution: Hand rail had been repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 May 2012 Resolved
High level bilge alarm inop. Make bilge alarm operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2012
Resolved 6 June 2012
Resolution: Tested high level alarm, sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 April 2007 Resolved
Provide report of service for the Fireboy and portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 8 May 2007
Construction/Loadline › Hull › Weld
Issued 25 April 2007 Resolved
Make repairs to the 12 cracked welds marked in passenger space and forward compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 8 May 2007
Lifesaving › Lifebuoys › Serviceable
Issued 5 May 2005 Resolved
Replace ring buoy with approved type outlined in 46 CFR 180.70(a)(2).
Due 5 June 2005
Resolved 17 June 2005
Resolution: Ring buoy replaced on 15 May 05.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 May 2005 Resolved
Provide PORMS with drug testing information for the year 2004 from program manager.
Due 5 June 2005
Resolved 7 July 2005
Resolution: Received Fax showing proof of program enrollment.
Construction/Loadline › Hull › Side Shell
Issued 5 May 2005 Resolved
Vee and weld cracks at chine on both PORT and STBD just aft of the operating station on exterior of hull. To be completed prior to carrying of passengers.
Due 5 June 2005
Resolved 17 June 2005
Resolution: Received email with statement attesting to the repairs and pictures showing completed repairs.
Construction/Loadline › Hull › Weld
Issued 5 May 2005 Resolved
Vee and weld cracks on the inboard saddle tanks both PORT and STBD side, to be completed prior to the carrying of passengers.
Due 5 June 2005
Resolved 17 June 2005
Resolution: Received email with statement attesting to the repairs and pictures showing completed repairs.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 May 2003 Resolved
Replace current worn jacket with approved jackets IAW 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 1 June 2003
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 May 2003 Resolved
Rewire fireboy audible alarm system to meet the requirements of 46 CFR 181.420
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 1 June 2003
Engineering › Gasoline Engine (propulsion)
Issued 1 May 2003 Resolved
Install fire sleeves over current REDLINE fuel hoses. 46 CFR 182.720 LEGACY COMPONENT DESC: Fuel Hose Fire Sleeves
Condition: Improper Installation
Due 1 June 2003
Resolved 1 June 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 2 May 2002 Resolved
Recharge FIREBOY halon bottle or install a 15lb CO2 (portable) mounted outside the engine room with the nozzle mounted in the engine room. If system is changed to CO2 provide 1 additional B-II extinguisher outside the engine room. 46 CFR 181.400 LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 2 June 2002
Resolved 11 June 2002
Engineering
Issued 2 May 2002 Resolved
Replace both power driven exhaust ducts. 46 CFR 460 LEGACY COMPONENT DESC: Exhaust Ducts
Condition: Improper/Lack of Maintenance
Due 2 June 2002
Resolved 11 June 2002
Construction/Loadline › Structures
Issued 2 May 2002 Resolved
Patch/plug all holes in gaps in forward engine room vapor bulkhead. 46 CFR 177.410(c). LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Due 2 June 2002
Resolved 11 June 2002
Lifesaving
Issued 6 May 1999 Resolved
PROVIDE THE FOLLOWING REPLACEMENT ITEMS FOR THE FIRST AID KIT: ASPRIN
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Engineering
Issued 6 May 1999 Resolved
REPAIR GASOLINE FUME DETECTION SYSTEM IN THE ENGINE/FUEL TANK COMPT: AUDIBLE SIGNAL NOT WORKING.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Construction/Loadline
Issued 8 May 1997 Resolved
MARK TRANSOM AND RING BUOY WITH VESSEL'S NAME.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Fire Fighting
Issued 8 May 1997 Resolved
PROVIDE 5 GPM HAND PUMP.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Documentation
Issued 8 May 1997 Resolved
PROVIDE OIL POLLUTION PLACARD.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Documentation
Issued 8 May 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 8 May 1997 Resolved
PROVIDE FIRST AID KIT MEETING OR EQUIVALENT TO 46 CFR 160.041.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Fire Fighting
Issued 8 May 1997 Resolved
HAVE 6 YEAR SERVICING PERFORMED ON BOTH PORT. FIRE EXTINGUISHERS OR REPLACE. (SIZE B-I)
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Documentation
Issued 11 May 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993