MAURY USCG vessel records
← All vessels

LIBERTAD

Built
1992
Last inspected
26 January 2023
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 January 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

379999
Flag
UNITED STATES
Maury page id
psix-379999

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

26 January 2023 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7627411
15 August 2022 Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7535626
16 March 2021 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7157419
22 May 2020 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6957958
28 February 2020 Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6931909
31 October 2019 In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6846604
31 October 2019 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6862651
30 May 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6699059
4 February 2019 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6619724
1 June 2018 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430881
13 February 2018 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6355153
1 March 2017 Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6097851
11 February 2016 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5813279

Deficiency record · 25

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2021 Resolved
Wooden access panel in way of forward section of operating station observed wasted. Renew as origional.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021 Resolved
Remove all dead end / abandoned electrical wires running along the centerline overhead (above PFD storage).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 13 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 March 2021 Resolved
Line for Lifebuoy light observed wasted and of incorrect type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 13 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2021 Resolved
New employees (deckhands) not provided documented training of duties expected to be performed on vessel as required by 185.510.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 October 2019 Resolved
High water bilge alarm visual indicator inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 25 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2019 Resolved
Chain link railing and clips at passenger access areas to vessel were observed wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 25 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. The independent fuel tank for the main propulsion engine was observed to be leaking gasoline due to the tank’s deteriorated material condition.
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Owner purchased a new independant fuel tank and installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 185.510 of this part. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Deckhand on duty was employed in this position for approximately two years. Deckhand was unfamiliar with emergency duties posted on emergency instruction placard. Crew training logs or documentation were not available for review by the Coast Guard. 46 CFR 185.420 (a)(c)
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following: (1) The location of emergency exits , survival craft embarkation areas, and ring life buoys; (2) The stowage location of life jackets; (3) Either: (i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning if a life jacket. (4) The location of the instruction placard for life jackets and other life saving devcices; (5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master. The deckhand stated that the passenger safety orientation only communicated the location of the life jackets to passengers and no other information or instruction was provided. 46 CFR 185.506
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons in the water that have fallen overboard. Drill logbook showed a man overboard drill was conducted on 29 May 2019; however, the crewmember stated no drill was conducted. The only other drills logged were in 2015. Deckhand was unable to demonstrate or describe duties required for emergencies in accordance with this regulation. 46 CFR 185.520
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 May 2019 Resolved
The master shall conduct sufficient fire drills to make sure that each crewmember is familiar with his or her duties in case of a fire. The deckhand was unable to demonstrate the activation and use of a portable fire extinguisher when requested to demonstrate a response to a simulated onboard fire by the attending Coast Guard Marine Inspector. 46 CFR 185.524 (a)
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 May 2019 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. A B-II portable fire extinguisher cylinder was observed wasted and not mounted in an approved bracket. 46 CFR 181.520
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: A replacement fire extinguisher was purchased and mounted in the appropriate bracket, inside forward storage, location is well marked.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 May 2019 Resolved
Each floating water light must be approved in accordance with 161.010 in Subchapter Q of this chapter, or other standard approved by the Commandant. The installed water light contained an unapproved battery, therefore negating its Coast Guard approval for its use as designed. 46 CFR 180.70 (d)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: The appropriate, approved, battery was purchased and installed in the water light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2019 Resolved
All vessels must have navigation lights that are incompliance with the applicable sections of the International and Inland Navigation Rules. The starboard running light was observed to be obscured by paint. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: New port and starboard navigation lights were purchased and appropriately installed on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first aid kit was missing items required by 160.041. 46 CFR 185.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2019
Resolution: A new approved first aid kit was purchased and put aboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock Electrical cabling and wiring in way of operating station observed to have dead end and exposed electrical wiring, incorrect connectors, and no identifiable circuit information. 46 CFR 183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Wiring under the operators station was redone to conform with regulations, using approved connectors and materials.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Exterior glass bulb lights on top of overhead were missing protective guards. Light fixtures were also observed cracked with exposed wiring. 46 CFR 183.300 & 183.410
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: broken lights and fixtures were removed from the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 17 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. U.S. Coast Guard inspector found that the displayed Certificate of Inspection was only of the second page of the presently issued two page Certificate of Inspection. 46 CFR 176.302
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: All pages of the COI are now displayed on the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019 Resolved
When in accordance with 178.210 of this chapter, The Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability Letter was not posted on vessel. 46 CFR 176.306
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Stability letter is now displayed on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Only one portable light was on the vessel. Operator placed a second portable battery light onboard vessel. 46 CFR 183.430
Action required: 10 - Deficiency Rectified
Resolved 17 December 2019
Construction/Loadline › Structures › Superstructure
Issued 11 February 2016 Resolved
Repair plywood woodrot in roof
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 1 June 2018
Resolution: rECTIFIED
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2016 Resolved
Install mechanical fastners on battery terminals
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 18 March 2016
Resolution: Battery replaced with approved terminals
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 February 2016 Resolved
Install approved 6v battery in float light
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 18 March 2016
Resolution: Approved Battery Installed.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 11 February 2016 Resolved
Obtain proper use endorsement for vessels service
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 1 June 2018
Resolution: Rectified

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.