LIBERTAD is a 1992 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1992, most recently in January 2023, along with 156 deficiencies and 1 operational control.

Records from 1992 to 2023. Most recent: inspection, 26 January 2023.

Built
1992
Last inspected
26 January 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

379999
Flag
UNITED STATES
—
Maury page id
psix-379999

Inspections, by type

…with no type recorded1
Years with a record 28 calendar years (1992–2023)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 58

26 January 2023 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7627411
15 August 2022 Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7535626
16 March 2021 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7157419
22 May 2020 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6957958
28 February 2020 Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6931909
31 October 2019 In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6846604
31 October 2019 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6862651
30 May 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6699059
4 February 2019 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6619724
1 June 2018 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430881
13 February 2018 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6355153
1 March 2017 Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6097851
11 February 2016 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5813279
29 December 2015 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5801577
27 December 2011 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4214469
24 January 2011 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3931927
27 December 2010 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 3922361
26 January 2010 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3670063
7 January 2010 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3660127
29 January 2009 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3521482
2 December 2008 Hull Examination · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3374094
21 July 2008 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3284130
17 April 2008 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3186818
30 January 2008 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3140130
6 December 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3114281
26 April 2007 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2916211
25 January 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2862146
18 October 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2803580
26 July 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2727466
19 April 2006 Hull Examination · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2637584
21 February 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2589082
18 January 2006 COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2569225
24 May 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2367714
20 January 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278422
30 March 2004 Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2035932
21 January 2004 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1992591
21 February 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1748544
30 January 2003 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1737904
13 March 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1598369
28 February 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1490273
22 January 2002 Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1488382
19 January 2001 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1382133
3 February 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 814648
3 February 2000 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415307
19 January 2000 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1429279
12 January 1999 Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1430643
29 January 1998 COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1457538
20 January 1998 Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1426025
21 March 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1089971
29 December 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1185320
1 November 1995 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360307
12 December 1994 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358624
22 November 1994 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355021
9 December 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850191
30 November 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 655236
21 September 1993 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373934
25 November 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 828030
26 October 1992 Hull Examination · Initial Certification · Inclining Experiment · Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460609

Deficiency record · 156

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2021 Resolved
Wooden access panel in way of forward section of operating station observed wasted. Renew as origional.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021 Resolved
Remove all dead end / abandoned electrical wires running along the centerline overhead (above PFD storage).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 13 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 March 2021 Resolved
Line for Lifebuoy light observed wasted and of incorrect type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 13 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2021 Resolved
New employees (deckhands) not provided documented training of duties expected to be performed on vessel as required by 185.510.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 October 2019 Resolved
High water bilge alarm visual indicator inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 25 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2019 Resolved
Chain link railing and clips at passenger access areas to vessel were observed wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 25 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. The independent fuel tank for the main propulsion engine was observed to be leaking gasoline due to the tank’s deteriorated material condition.
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Owner purchased a new independant fuel tank and installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 185.510 of this part. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Deckhand on duty was employed in this position for approximately two years. Deckhand was unfamiliar with emergency duties posted on emergency instruction placard. Crew training logs or documentation were not available for review by the Coast Guard. 46 CFR 185.420 (a)(c)
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following: (1) The location of emergency exits , survival craft embarkation areas, and ring life buoys; (2) The stowage location of life jackets; (3) Either: (i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning if a life jacket. (4) The location of the instruction placard for life jackets and other life saving devcices; (5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master. The deckhand stated that the passenger safety orientation only communicated the location of the life jackets to passengers and no other information or instruction was provided. 46 CFR 185.506
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons in the water that have fallen overboard. Drill logbook showed a man overboard drill was conducted on 29 May 2019; however, the crewmember stated no drill was conducted. The only other drills logged were in 2015. Deckhand was unable to demonstrate or describe duties required for emergencies in accordance with this regulation. 46 CFR 185.520
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 May 2019 Resolved
The master shall conduct sufficient fire drills to make sure that each crewmember is familiar with his or her duties in case of a fire. The deckhand was unable to demonstrate the activation and use of a portable fire extinguisher when requested to demonstrate a response to a simulated onboard fire by the attending Coast Guard Marine Inspector. 46 CFR 185.524 (a)
Action required: 30 - Ship detained
Resolved 12 June 2019
Resolution: Vessel conducted extensive training in Fire, man over board, and emergency procedures. Crew demonstrated satisfactory drills and safety brief procedures.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 May 2019 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. A B-II portable fire extinguisher cylinder was observed wasted and not mounted in an approved bracket. 46 CFR 181.520
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: A replacement fire extinguisher was purchased and mounted in the appropriate bracket, inside forward storage, location is well marked.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 May 2019 Resolved
Each floating water light must be approved in accordance with 161.010 in Subchapter Q of this chapter, or other standard approved by the Commandant. The installed water light contained an unapproved battery, therefore negating its Coast Guard approval for its use as designed. 46 CFR 180.70 (d)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: The appropriate, approved, battery was purchased and installed in the water light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2019 Resolved
All vessels must have navigation lights that are incompliance with the applicable sections of the International and Inland Navigation Rules. The starboard running light was observed to be obscured by paint. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: New port and starboard navigation lights were purchased and appropriately installed on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first aid kit was missing items required by 160.041. 46 CFR 185.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2019
Resolution: A new approved first aid kit was purchased and put aboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock Electrical cabling and wiring in way of operating station observed to have dead end and exposed electrical wiring, incorrect connectors, and no identifiable circuit information. 46 CFR 183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Wiring under the operators station was redone to conform with regulations, using approved connectors and materials.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Exterior glass bulb lights on top of overhead were missing protective guards. Light fixtures were also observed cracked with exposed wiring. 46 CFR 183.300 & 183.410
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: broken lights and fixtures were removed from the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 17 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. U.S. Coast Guard inspector found that the displayed Certificate of Inspection was only of the second page of the presently issued two page Certificate of Inspection. 46 CFR 176.302
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: All pages of the COI are now displayed on the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019 Resolved
When in accordance with 178.210 of this chapter, The Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability Letter was not posted on vessel. 46 CFR 176.306
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Stability letter is now displayed on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Only one portable light was on the vessel. Operator placed a second portable battery light onboard vessel. 46 CFR 183.430
Action required: 10 - Deficiency Rectified
Resolved 17 December 2019
Construction/Loadline › Structures › Superstructure
Issued 11 February 2016 Resolved
Repair plywood woodrot in roof
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 1 June 2018
Resolution: rECTIFIED
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2016 Resolved
Install mechanical fastners on battery terminals
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 18 March 2016
Resolution: Battery replaced with approved terminals
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 February 2016 Resolved
Install approved 6v battery in float light
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 18 March 2016
Resolution: Approved Battery Installed.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 11 February 2016 Resolved
Obtain proper use endorsement for vessels service
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 1 June 2018
Resolution: Rectified
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 January 2011 Resolved
owner to replace retroreflective tape on all lifejackets.
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 28 January 2011
Resolution: owner replaced retro-tape
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 January 2011 Resolved
light not working replace batteries
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 24 January 2011
Resolution: batteries replaced
Fire Fighting › Fire Bucket › Availability
Issued 24 January 2011 Resolved
missing (3) fire buckets.
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 28 January 2011
Resolution: (3) fire buckets were placed on board and stenciled.
Engineering › Bilge Water Management System › Pump
Issued 24 January 2011 Resolved
missing hose for hand pump
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 28 January 2011
Resolution: hose purchased and placed on board.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 December 2010 Resolved
wires need to be bundled properly and neatly
Action required: 705 - Other - as specified
Due 27 December 2010
Resolved 4 January 2011
Resolution: All wires have been put in a neatly order.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2007 Resolved
Positive cable for main battery loose at battery pole.
Condition: Improper/Lack of Maintenance
Due 26 April 2007
Resolved 26 April 2007
Resolution: Corrected on the spot.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 July 2006 Resolved
Owner to be the only person to operate vessel with passengers for hire. Crewmember to assist owner as 2nd master under direct supervision of licensed owner due to expired license while transisting back to from the islands.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2006
Resolution: Returned to site and witnessed full compliance of requirement. Item also verified on 27 and 28 Jul 06.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 July 2006 Resolved
Ensure that there are sufficient child lifejacket to accomodate all children aboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2006
Resolution: Owner temporary using lifejacket from his other vsl. Vsl have 11 child size lifejackets on board. Item also verified on 27Jul06 and found in compliance.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 26 July 2006 Resolved
Mount emergency instructions at the operating station containing at least the applicable instructions listed in 46CFR185.512.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2006
Resolution: Instructions mounted.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 July 2006 Resolved
Provide alcohol testing kits for each crewmember as per 46CFR4.06-20 to be used in case of a serious marine incident.
Condition: Unknown
Due 26 August 2006
Resolved 25 January 2007
Resolution: Kit provided for each crewmember.
Documentation › Logs/Records › Logbook (official)
Issued 18 January 2006 Resolved
Provide current training logbook as required by 46CFR185.420.
Condition: Improper/Lack of Maintenance
Due 18 February 2006
Resolved 21 February 2006
Resolution: Provided.
Lifesaving › Hand Flares › Storage
Issued 18 January 2006 Resolved
Provide a brightly colored, portable waterlight container for the smoke signals.
Condition: Improper Installation
Due 18 February 2006
Resolved 21 February 2006
Resolution: Provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 18 January 2006 Resolved
Separate the B-II portable fire extinguishers.
Condition: Improper Installation
Due 18 February 2006
Resolved 21 February 2006
Resolution: Extinguisher separated forward.
Engineering › Bilge Water Management System › Pump
Issued 18 January 2006 Resolved
Eliminate the obsolete bilge pump aft.
Condition: Improper Installation
Due 18 February 2006
Resolved 21 February 2006
Resolution: Pump eliminated.
Engineering › Bilge Water Management System › Hose
Issued 18 January 2006 Resolved
Provide hose clamps to bilge pumps aft.
Condition: Improper/Lack of Maintenance
Due 18 February 2006
Resolved 21 February 2006
Resolution: Clamps provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 January 2005 Resolved
Provide required burn cream for the first aid kit.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 27 January 2005
Resolution: Provided.
Electrical › Electric Supply System (service) › Cable
Issued 20 January 2005 Resolved
Repair the negative post cable to main electrical battery.
Condition: Design Flaw
Due 27 January 2005
Resolved 27 January 2005
Resolution: Repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 January 2005 Resolved
Provide battery tray for battery with required cover and endure tray is secure to deck.
Condition: Improper Installation
Due 27 January 2005
Resolved 27 January 2005
Resolution: Provided.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 20 January 2005 Resolved
Provide holding straps for the portable fuel tanks.
Condition: Improper Installation
Due 27 January 2005
Resolved 27 January 2005
Resolution: Provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 January 2005 Resolved
Repair or remove the electric light fixtures above the pilot station.
Condition: Damaged By Earlier Event
Due 27 January 2005
Resolved 27 January 2005
Resolution: Light Replaced.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 January 2005 Resolved
Provide evidence of enrollment in the Maritime Drug Testing Consortiun.
Due 21 January 2005
Resolved 21 January 2005
Resolution: Verified via phone with the Maritime Consortium proper enrollment.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Renew main deck plywood starboard side from forward of passenger entrance to aft of the pilot station and reseal with fiberglass. Wood under FRP rotted. LEGACY COMPONENT DESC: Main Deck
Condition: Damaged By Earlier Event
Due 15 April 2004
Resolved 1 April 2004
Resolution: Wood replaced.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Renew main deck plywood, with marine grade plywood, portside by aft passenger entrance and reseal with fiberglass. Wood under FRP rotted. Repair to be to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Main Deck
Due 30 April 2004
Resolved 6 May 2004
Resolution: Verified by [name withheld]..
Construction/Loadline › Structures
Issued 30 March 2004 Resolved
Renew wood frame amidships forward of pilot station.
Due 15 April 2004
Resolved 1 April 2004
Resolution: Renewed.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Renew main deck plywood at transom with marine grade plywood and reseal with FRP. LEGACY COMPONENT DESC: Main Deck Aft
Due 30 April 2004
Resolved 6 May 2004
Resolution: Verified by [name withheld]..
Construction/Loadline › Structures
Issued 30 March 2004 Resolved
Renew cover for access to bilges amidships forward of pilot station.
Due 15 April 2004
Resolved 1 April 2004
Resolution: Renewed.
Construction/Loadline › Structures
Issued 30 March 2004 Resolved
Renew cover for seating bench forward.
Due 15 April 2004
Resolved 1 April 2004
Resolution: Renewed.
Construction/Loadline › Structures
Issued 30 March 2004 Resolved
Replace 2x4 wood supports (2 ea) for seating bench forward.
Due 15 April 2004
Resolved 1 April 2004
Resolution: Replaced.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Reseal with fiberglass the starboard side of transom's hull above main deck to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Transom
Due 30 April 2004
Resolved 6 May 2004
Resolution: Verified by [name withheld]..
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Grind and reseal starboard side of the outside hull amidships by passengers entrance. LEGACY COMPONENT DESC: Hull Plating
Condition: Design Flaw
Due 15 April 2004
Resolved 1 April 2004
Resolution: Repaired.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Reseal with fiberglass the starboard side of bow as marked. LEGACY COMPONENT DESC: Hull Plating
Condition: Design Flaw
Due 15 April 2004
Resolved 1 April 2004
Resolution: Resealed.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Repair hull just under the bow as marked. LEGACY COMPONENT DESC: Hull Plating
Condition: Design Flaw
Due 15 April 2004
Resolved 1 April 2004
Resolution: Repaired.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Grind and reseal portside 1/3 forward of the under hull as marked. LEGACY COMPONENT DESC: Hull Plating
Condition: Design Flaw
Due 15 April 2004
Resolved 1 April 2004
Resolution: Repaired.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Reseal with fiberglass the starboard side corner aft by transom above the water line. LEGACY COMPONENT DESC: Hull Plating
Condition: Design Flaw
Due 15 April 2004
Resolved 1 April 2004
Resolution: Resealed.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Grind and reseal starboard side forward under vessel's registration number. LEGACY COMPONENT DESC: Hull Plating
Due 15 April 2004
Resolved 1 April 2004
Resolution: Repaired.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Grind and reseal starboard side amidships under hull. as marked LEGACY COMPONENT DESC: Hull Plating
Due 15 April 2004
Resolved 1 April 2004
Resolution: Repaired.
Documentation › Certificates/Documents
Issued 21 January 2004 Resolved
Provide evidence that the company is enrolled in a drug and alcohol consortium. LEGACY COMPONENT DESC: Proof of Consortium Enrollment (DAPI)
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 9 February 2004
Resolution: Verified via telephone with the Maritime Consortium.
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 January 2004 Resolved
Label child size lifejackets stowage. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 5 March 2004
Resolved 5 March 2004
Resolution: Labeled.
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 January 2004 Resolved
Provide Coast Guard or equivalent first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 5 March 2004
Resolved 5 March 2004
Resolution: Provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 21 January 2004 Resolved
Provide 2 B-II portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2004
Resolved 21 January 2004
Resolution: New extinguishers provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 21 January 2004 Resolved
Provide 1 B-I portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2004
Resolved 21 January 2004
Resolution: New extinguisher provided.
Engineering › Gasoline Engine (propulsion)
Issued 21 January 2004 Resolved
Replace fuel hose for the portable gasoline tank. LEGACY COMPONENT DESC: Fuel Line
Condition: Design Flaw
Due 21 February 2004
Resolved 25 February 2004
Resolution: Hose replaced.
Engineering › Bilge Water Management System
Issued 21 January 2004 Resolved
Provide visual indicator for the bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 5 March 2004
Resolved 5 March 2004
Resolution: Provided.
Engineering › Bilge Water Management System
Issued 21 January 2004 Resolved
Provide visual and audible alarm for the bilge high level alarm at the operating station. LEGACY COMPONENT DESC: High level alarm
Condition: Improper/Lack of Maintenance
Due 5 March 2004
Resolved 5 March 2004
Resolution: Provided.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 January 2004 Resolved
Provide 2 portable lights (flashlights). LEGACY COMPONENT DESC: Portable lights
Condition: Unknown
Due 21 February 2004
Resolved 25 February 2004
Resolution: Provided.
Engineering › Bilge Water Management System
Issued 21 January 2004 Resolved
Provide a portable bilge pump of 5 GPM. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 21 February 2004
Resolved 25 February 2004
Resolution: Provided.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 January 2004 Resolved
Provide safety chain or strong line, port and starboard, to protect open spaces between safety rails. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 21 February 2004
Resolved 25 February 2004
Resolution: Provided.
Lifesaving › Lifejacket/PFD (General)
Issued 21 January 2004 Resolved
Provide donning placard for lifejackets. LEGACY COMPONENT DESC: Donning Placard
Condition: Improper/Lack of Maintenance
Due 21 February 2004
Resolved 25 February 2004
Resolution: Provided.
Construction/Loadline › Hull
Issued 21 January 2004 Resolved
Repair forward cleats, port and starboard. LEGACY COMPONENT DESC: Cleats
Condition: Damaged By Earlier Event
Due 21 February 2004
Resolved 25 February 2004
Resolution: Repaired.
Electrical › Electric Supply System (service)
Issued 21 January 2004 Resolved
Provide a corrosion- resistant tray for main batteries with protective cover. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 21 February 2004
Resolved 25 February 2004
Resolution: Provided.
Electrical › Electrical Distribution System (service)
Issued 21 January 2004 Resolved
Repair and remove obsolete electrical wires for space above pilot station. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 21 February 2004
Resolved 25 February 2004
Resolution: Wires removed.
Engineering › Bilge Water Management System
Issued 21 January 2004 Resolved
Make operational or remove starboard bilge pump. Vessel only require 1 bilge pump aft. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 21 February 2004
Resolved 25 February 2004
Resolution: Repaired.
Electrical › Electrical Distribution System (service)
Issued 21 January 2004 Resolved
Repair electrical supply system to bilge pumps so that the pumps are protected by a circuit breaker at the pilot station. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Due 5 March 2004
Resolved 5 March 2004
Resolution: Repaired.
Lifesaving › Hand Flares
Issued 21 January 2004 Resolved
Provide a brightly colored , portable waterlight container for the distress signals and marked " Distress Signals". LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 21 February 2004
Resolved 25 February 2004
Resolution: Provided.
Electrical › Electrical Distribution System (service)
Issued 30 January 2003 Resolved
Remove all obsolete electrical wires and reconnected loose wires under the pilot station LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 28 February 2003
Resolved 21 February 2003
Resolution: Wires repaired.
Lifesaving
Issued 30 January 2003 Resolved
Replace expired medication and provide mssing items from the first aid kit to include: eye wash solution, burn treatment compound, ammonia inhalants, and aspin tablets.
Condition: Improper/Lack of Maintenance
Due 28 February 2003
Resolved 21 February 2003
Resolution: Provided.
Lifesaving › Lifebuoys
Issued 30 January 2003 Resolved
Provide a 24" CG approved lifebuoy with a 60 feet dark color line, and attached to the waterlight via a quick release clip. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 28 February 2003
Resolved 30 January 2003
Resolution: Replace on the spot.
Lifesaving › Lifebuoys
Issued 30 January 2003 Resolved
Provide bracket for lifebuoy. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Due 28 February 2003
Resolved 21 February 2003
Resolution: New buoy provided with bracket.
Documentation › Certificates/Documents
Issued 30 January 2003 Resolved
Make arrangement to obtain copy of the certificate from the Maritime drug testing consortium as soon as possible, and provide to Marine Inspector. ( Evidence of compliance for renewal to the consortium was verified via phone by Marine Inspector during this inspection. See Narrative for details)
Due 28 February 2003
Resolved 21 February 2003
Resolution: New certificate provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 January 2002 Resolved
Portable bottle was missing discharge pin.
Condition: Improper/Lack of Maintenance
Due 22 February 2002
Resolved 22 February 2002
Resolution: Owner bought new portable fire extinguisher same date..
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 January 2002 Resolved
Properly Install or mount portable fire extinguisher holding bracket..
Due 28 February 2002
Resolved 28 February 2002
Resolution: Corrected this date.
Lifesaving › Hand Flares
Issued 22 January 2002 Resolved
Replace all expired hand flares ( 3 orange flares and 3 red flares).
Condition: Unknown
Due 22 January 2002
Resolved 22 January 2002
Resolution: Owner purchased all required hand flares same date of inspection..
Lifesaving › Buoyant Apparatus
Issued 22 January 2002 Resolved
Replace worn ring bouy line.
Due 28 February 2002
Resolved 28 February 2002
Resolution: Replaced this date.
Lifesaving
Issued 22 January 2002 Resolved
Obtain complete First Aid Kit. LEGACY COMPONENT DESC: First Aid kit
Condition: Unknown
Due 28 February 2002
Resolved 22 January 2002
Resolution: Owner purchased frist aid kit.
Lifesaving › Lifejacket/PFD (Type II)
Issued 22 January 2002 Resolved
Install new reflector tape to 4 adult PFDs and to 3 children PFDs. LEGACY COMPONENT DESC: Reflector tape
Due 28 February 2002
Resolved 28 February 2002
Resolution: All corrected this date.
Operations/Management › Drug and Alcohol Testing
Issued 22 January 2002 Resolved
Present proof that the desiganted vessel's master is part of company's Drug and Alcohol testing Program. LEGACY COMPONENT DESC: Master not listed in Company''s ltr.
Due 22 January 2002
Resolved 22 January 2002
Resolution: Owner called Maritime Consortium and re added present master back to the list of employees as it was in last years'' list.
Lifesaving
Issued 19 January 2001 Resolved
Write name of vessel on vessel's life ring.
Condition: Unknown
Due 19 January 2001
Resolved 8 February 2001
Construction/Loadline
Issued 19 January 2001 Resolved
Properly intstall inoperative high water level alarm forward.
Condition: Unknown
Due 21 January 2001
Resolved 8 February 2001
Documentation
Issued 19 January 2001 Resolved
Provide current training log book.
Condition: Unknown
Due 21 January 2001
Resolved 8 February 2001
Lifesaving
Issued 19 January 2001 Resolved
Install instructions placard for downing of PFDs and safety instructions topassengers.
Condition: Unknown
Due 21 January 2001
Resolved 8 February 2001
Lifesaving
Issued 19 January 2001 Resolved
Have on board, required red flares (3).
Condition: Unknown
Due 19 January 2001
Resolved 8 February 2001
Construction/Loadline
Issued 3 February 2000 Resolved
REGLASS PORT AND STARBOARD TRANSOM UPPER CORNERS.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 3 February 2000 Resolved
REPLACE ROTTED WOOD IWO TRANSOM, UNDER/AROUND ENGINE MOUNT
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 3 February 2000 Resolved
RE-ATTACH STARBOARD AFT CLEAT
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 3 February 2000 Resolved
REPLACE ROTTED WOOD IWO INSIDE TRANSOM, PORT SIDE BOTTOM CORNER
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Lifesaving
Issued 19 January 2000 Resolved
PROVIDE THREE(3) RED FLARES
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 19 January 2000 Resolved
PROVIDE A COMPLETE FIRST AID KIT
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 19 January 2000 Resolved
ATTACH PROPER LENGTH OF DARK LINE TO LIFERING AND FLOAT LIGHT.
Condition: Unknown
Due 19 February 2000
Resolved 3 February 2000
Electrical
Issued 19 January 2000 Resolved
PROPERLY WIRE HIGH LEVEL BILGE ALARM
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Electrical
Issued 19 January 2000 Resolved
PROPERLY WIRE ELECTRICAL BILGE PUMPS
Condition: Unknown
Due 19 February 2000
Resolved 3 February 2000
Electrical
Issued 19 January 2000 Resolved
PROPERLY WIRE NAV LIGHTS
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 19 January 2000 Resolved
PROVIDE FLOATLIGHT
Condition: Unknown
Due 19 February 2000
Resolved 3 February 2000
Electrical
Issued 19 January 2000 Resolved
PROPERLY WIRE BATTERY TERMINAL
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Fire Fighting
Issued 19 January 2000 Resolved
PROVIDE THREE (3) FIRE BUCKETS
Condition: Unknown
Due 19 February 2000
Resolved 3 February 2000
Fire Fighting
Issued 12 January 1999 Resolved
PROVIDE THREE FIRE BUCKETS
Condition: Unknown
Due 13 February 1999
Resolved 11 March 1999
Lifesaving
Issued 12 January 1999 Resolved
PROVIDE LIFEJACKET PLACARD/DONNING INSTRUCTIONS
Condition: Unknown
Due 13 February 1999
Resolved 11 March 1999
Lifesaving
Issued 12 January 1999 Resolved
INSTALL REFLECTIVE TAPE IN RING BUOY
Condition: Unknown
Due 13 February 1999
Resolved 11 March 1999
Construction/Loadline
Issued 12 January 1999 Resolved
INSTALL DOUBLE CLAMPS IWO BILGE PUMPS HOSES
Condition: Unknown
Due 13 February 1999
Resolved 11 March 1999
Accommodation/Occupational Safety
Issued 12 January 1999 Resolved
INSTALL SAFETY HOOKS IN PORT/STARBOARD DOORS
Condition: Unknown
Due 13 February 1999
Resolved 11 March 1999
Documentation
Issued 12 January 1999 Resolved
PROVIDE EVIDENCE OF FULLY COMPLIANT DRUG TESTING PROGRAM.
Condition: Unknown
Due 12 February 1999
Resolved 11 March 1999
Documentation
Issued 12 January 1999 Resolved
PROVIDE CREW TRAINING LOG
Condition: Unknown
Due 12 February 1999
Resolved 11 March 1999
Lifesaving
Issued 29 January 1998 Resolved
PROVIDE WATERPROOF CONTAINER TO STORE VISUAL DISTRESS SIGNALS. CONTAINER TO BE MARKED "DISTRESS SIGNALS".
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Lifesaving
Issued 29 January 1998 Resolved
PROVIDE WATER PROOF CONTAINER FOR FIRST AID KIT CONTENTS
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Engineering
Issued 29 January 1998 Resolved
RE-ROUTE OUTBOARD ENGINE'S POWER TRIM CABLE TO PREVENT FURTHER PINCHING.
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Engineering
Issued 29 January 1998 Resolved
SECURE FUEL TANKS IN PLACE
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Engineering
Issued 29 January 1998 Resolved
REPAIR THE REVERSE FUNCTION OF OUTBOARD ENGINE
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Electrical
Issued 29 January 1998 Resolved
LABEL ELECTRICAL SWITCHES IN CONTROL STATION
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Deck/Cargo
Issued 29 January 1998 Resolved
REPLACE WORN OUT ANCHOR CHAIN
Condition: Unknown
Due 28 February 1998
Resolved 11 February 1998
Documentation
Issued 29 January 1998 Resolved
PROVIDE EVIDENCE OF DRUG TESTING
Condition: Unknown
Due 28 February 1998
Resolved 4 March 1998
Construction/Loadline
Issued 20 January 1998 Resolved
RE-FASTEN SUPPORTS UNDER CENTER SITTING BENCH.
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE DELAMINATION ON THE PORT BUMPER GUARD
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE FORWARD PORTION OF PORT BUMPER GUARD
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE PORTION OF PORT SIDESHELL FORWARD, WHERE IT JOINS BOTTOM.
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
SEAL AREA AROUND FORWARD TRAILER EYE BOLT
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE DELAMINATED PORTION OF STARBOARD BUMPER GUARD FORWARD
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE THE AFT SECTION OF STARBOARD SIDE BUMPER GUARD.
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Accommodation/Occupational Safety
Issued 20 January 1998 Resolved
REPLACE BROKEN SAFETY CHAIN CONNECTORS ON PORT AND STARBOARD SIDES
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Accommodation/Occupational Safety
Issued 20 January 1998 Resolved
RE-FASTEN PORT AND STARBOARD ENTRANCE DOORS
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND RELAMINATE UPPER EDGE OF TRANSOM.
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE 32 INCHES OF KEEL, FROM TRANSOM FORWARD
Condition: Unknown
Due 28 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
GRIND OUT AND REGLAZE PORTION WHERE THE TRANSOM JOINS STARBOARD SIDE SHELL.
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 20 January 1998 Resolved
SECURE WIRING FOR RADIO/CASSETTE PLAYER AND REMOVE UNUSED/DEAD WIRING FROM RADIO CONSOLE ABOVE CONTROL STATION
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Documentation
Issued 20 January 1998 Resolved
PROVIDE COPY OF STABILITY LETTER
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Accommodation/Occupational Safety
Issued 20 January 1998 Resolved
ATTACH CONNECTOR TO PORT AND STARBOARD DOORS TO ENSURE THEY REMAIN CLOSED
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Accommodation/Occupational Safety
Issued 20 January 1998 Resolved
RE-FASTEN STARBOARD BOW INBOARD MIDDLE SAFETY RAILING.
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Construction/Loadline
Issued 20 January 1998 Resolved
RE-FASTEN PIECE OF PLYWOOD LOCATED IN THE AFT SECTION OF CENTER SITTING BENCH
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 20 January 1998 Resolved
REPLACE CRACKED POS BATTERY CABLE CONNECTOR
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 20 January 1998 Resolved
REPLACE DAMAGED POS BATTERY CABLE
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 20 January 1998 Resolved
SECURE POS/NEG BATTERY CONNECTORS
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 20 January 1998 Resolved
SECURE BATTERY CABLES AROUND TERMINALS
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 20 January 1998 Resolved
INSTALL MISSING LIGHT COVERS
Condition: Unknown
Due 20 February 1998
Resolved 10 February 1998
Electrical
Issued 1 November 1995 Resolved
PLACE BATTERIES IN ACID RESISTANT BOX.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 December 1995
Resolved 26 December 1995
Accommodation/Occupational Safety
Issued 1 November 1995 Resolved
REMOUNT GATE HINGE, PORT SIDE FORWARD.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
INSTALL SECOND BATTERY.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Lifesaving
Issued 1 November 1995 Resolved
REPAIR OR RENEW WOOD PANEL ON FRONT SIDE OF CONTROL STATION.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Construction/Loadline
Issued 22 November 1994 Resolved
Install transom bolts with washers and nuts tightened.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Construction/Loadline
Issued 22 November 1994 Resolved
Replace 1 eight X four sheet of plywood along stbd side in way of impacted area at turn of chine.
Condition: Unknown
Due 22 November 1994
Resolved 30 November 1994
Documentation
Issued 21 September 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Documentation
Issued 21 September 1993 Resolved
Provide documentation that a drug testing program that complies with 46 Code of Federal Regulations Part 16 is in place.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Documentation
Issued 26 October 1992 Resolved
Provide Coast Guard approved plans in accordance with 46 CFR 177.05-1._x001C_
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.