LIBERTAD
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named LIBERTAD
LIBERTAD is a 1992 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1992, most recently in January 2023, along with 156 deficiencies and 1 operational control.
Records from 1992 to 2023. Most recent: inspection, 26 January 2023.
- Built
- 1992
- Last inspected
- 26 January 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 156 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded1
Years with a record
28 calendar years (1992–2023)
The 58 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 58
26 January 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7627411
15 August 2022
Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7535626
16 March 2021
Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7157419
22 May 2020
Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6957958
28 February 2020
Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6931909
31 October 2019
In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6846604
31 October 2019
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6862651
30 May 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6699059
4 February 2019
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6619724
1 June 2018
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430881
13 February 2018
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6355153
1 March 2017
Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6097851
11 February 2016
COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5813279
29 December 2015
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5801577
27 December 2011
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4214469
24 January 2011
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3931927
27 December 2010
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 3922361
26 January 2010
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3670063
7 January 2010
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3660127
29 January 2009
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3521482
2 December 2008
Hull Examination · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3374094
21 July 2008
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3284130
17 April 2008
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3186818
30 January 2008
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3140130
6 December 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3114281
26 April 2007
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2916211
25 January 2007
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2862146
18 October 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2803580
26 July 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2727466
19 April 2006
Hull Examination · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2637584
21 February 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2589082
18 January 2006
COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2569225
24 May 2005
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2367714
20 January 2005
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278422
30 March 2004
Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2035932
21 January 2004
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1992591
21 February 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1748544
30 January 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1737904
13 March 2002
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1598369
28 February 2002
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1490273
22 January 2002
Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1488382
19 January 2001
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1382133
3 February 2000
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 814648
3 February 2000
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415307
19 January 2000
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1429279
12 January 1999
Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1430643
29 January 1998
COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1457538
20 January 1998
Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1426025
21 March 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1089971
29 December 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1185320
1 November 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360307
12 December 1994
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358624
22 November 1994
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355021
9 December 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850191
30 November 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 655236
21 September 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373934
25 November 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 828030
26 October 1992
Hull Examination · Initial Certification · Inclining Experiment · Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460609
Deficiency record · 156
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2021
Resolved
Wooden access panel in way of forward section of operating station observed wasted. Renew as origional.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021
Resolved
Remove all dead end / abandoned electrical wires running along the centerline overhead (above PFD storage).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 March 2021
Resolved
Line for Lifebuoy light observed wasted and of incorrect type.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2021
Resolved
New employees (deckhands) not provided documented training of duties expected to be performed on vessel as required by 185.510.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 October 2019
Resolved
High water bilge alarm visual indicator inoperative.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2019
Resolved
Chain link railing and clips at passenger access areas to vessel were observed wasted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. The independent fuel tank for the main propulsion engine was observed to be leaking gasoline due to the tank’s deteriorated material condition.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 185.510 of this part. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Deckhand on duty was employed in this position for approximately two years. Deckhand was unfamiliar with emergency duties posted on emergency instruction placard. Crew training logs or documentation were not available for review by the Coast Guard.
46 CFR 185.420 (a)(c)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following:
(1) The location of emergency exits , survival craft embarkation areas, and ring life buoys;
(2) The stowage location of life jackets;
(3) Either: (i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning if a life jacket.
(4) The location of the instruction placard for life jackets and other life saving devcices;
(5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master.
The deckhand stated that the passenger safety orientation only communicated the location of the life jackets to passengers and no other information or instruction was provided.
46 CFR 185.506
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons in the water that have fallen overboard. Drill logbook showed a man overboard drill was conducted on 29 May 2019; however, the crewmember stated no drill was conducted. The only other drills logged were in 2015. Deckhand was unable to demonstrate or describe duties required for emergencies in accordance with this regulation.
46 CFR 185.520
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 May 2019
Resolved
The master shall conduct sufficient fire drills to make sure that each crewmember is familiar with his or her duties in case of a fire. The deckhand was unable to demonstrate the activation and use of a portable fire extinguisher when requested to demonstrate a response to a simulated onboard fire by the attending Coast Guard Marine Inspector.
46 CFR 185.524 (a)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 May 2019
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. A B-II portable fire extinguisher cylinder was observed wasted and not mounted in an approved bracket. 46 CFR 181.520
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 May 2019
Resolved
Each floating water light must be approved in accordance with 161.010 in Subchapter Q of this chapter, or other standard approved by the Commandant. The installed water light contained an unapproved battery, therefore negating its Coast Guard approval for its use as designed.
46 CFR 180.70 (d)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2019
Resolved
All vessels must have navigation lights that are incompliance with the applicable sections of the International and Inland Navigation Rules. The starboard running light was observed to be obscured by paint.
46 CFR 183.420
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first aid kit was missing items required by 160.041.
46 CFR 185.710
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock
Electrical cabling and wiring in way of operating station observed to have dead end and exposed electrical wiring, incorrect connectors, and no identifiable circuit information.
46 CFR 183.340
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Exterior glass bulb lights on top of overhead were missing protective guards. Light fixtures were also observed cracked with exposed wiring.
46 CFR 183.300 & 183.410
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. U.S. Coast Guard inspector found that the displayed Certificate of Inspection was only of the second page of the presently issued two page Certificate of Inspection.
46 CFR 176.302
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
When in accordance with 178.210 of this chapter, The Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability Letter was not posted on vessel.
46 CFR 176.306
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Only one portable light was on the vessel. Operator placed a second portable battery light onboard vessel.
46 CFR 183.430
Construction/Loadline › Structures › Superstructure
Issued 11 February 2016
Resolved
Repair plywood woodrot in roof
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2016
Resolved
Install mechanical fastners on battery terminals
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 February 2016
Resolved
Install approved 6v battery in float light
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 11 February 2016
Resolved
Obtain proper use endorsement for vessels service
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 January 2011
Resolved
owner to replace retroreflective tape on all lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 January 2011
Resolved
light not working replace batteries
Fire Fighting › Fire Bucket › Availability
Issued 24 January 2011
Resolved
missing (3) fire buckets.
Engineering › Bilge Water Management System › Pump
Issued 24 January 2011
Resolved
missing hose for hand pump
Electrical › Electrical Distribution System (service) › Cable
Issued 27 December 2010
Resolved
wires need to be bundled properly and neatly
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2007
Resolved
Positive cable for main battery loose at battery pole.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 July 2006
Resolved
Owner to be the only person to operate vessel with passengers for hire. Crewmember to assist owner as 2nd master under direct supervision of licensed owner due to expired license while transisting back to from the islands.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 July 2006
Resolved
Ensure that there are sufficient child lifejacket to accomodate all children aboard.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 26 July 2006
Resolved
Mount emergency instructions at the operating station containing at least the applicable instructions listed in 46CFR185.512.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 July 2006
Resolved
Provide alcohol testing kits for each crewmember as per 46CFR4.06-20 to be used in case of a serious marine incident.
Documentation › Logs/Records › Logbook (official)
Issued 18 January 2006
Resolved
Provide current training logbook as required by 46CFR185.420.
Lifesaving › Hand Flares › Storage
Issued 18 January 2006
Resolved
Provide a brightly colored, portable waterlight container for the smoke signals.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 18 January 2006
Resolved
Separate the B-II portable fire extinguishers.
Engineering › Bilge Water Management System › Pump
Issued 18 January 2006
Resolved
Eliminate the obsolete bilge pump aft.
Engineering › Bilge Water Management System › Hose
Issued 18 January 2006
Resolved
Provide hose clamps to bilge pumps aft.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 January 2005
Resolved
Provide required burn cream for the first aid kit.
Electrical › Electric Supply System (service) › Cable
Issued 20 January 2005
Resolved
Repair the negative post cable to main electrical battery.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 January 2005
Resolved
Provide battery tray for battery with required cover and endure tray is secure to deck.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 20 January 2005
Resolved
Provide holding straps for the portable fuel tanks.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 January 2005
Resolved
Repair or remove the electric light fixtures above the pilot station.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 January 2005
Resolved
Provide evidence of enrollment in the Maritime Drug Testing Consortiun.
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Renew main deck plywood starboard side from forward of passenger entrance to aft of the pilot station and reseal with fiberglass. Wood under FRP rotted. LEGACY COMPONENT DESC: Main Deck
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Renew main deck plywood, with marine grade plywood, portside by aft passenger entrance and reseal with fiberglass. Wood under FRP rotted. Repair to be to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Main Deck
Construction/Loadline › Structures
Issued 30 March 2004
Resolved
Renew wood frame amidships forward of pilot station.
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Renew main deck plywood at transom with marine grade plywood and reseal with FRP. LEGACY COMPONENT DESC: Main Deck Aft
Construction/Loadline › Structures
Issued 30 March 2004
Resolved
Renew cover for access to bilges amidships forward of pilot station.
Construction/Loadline › Structures
Issued 30 March 2004
Resolved
Renew cover for seating bench forward.
Construction/Loadline › Structures
Issued 30 March 2004
Resolved
Replace 2x4 wood supports (2 ea) for seating bench forward.
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Reseal with fiberglass the starboard side of transom's hull above main deck to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Transom
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Grind and reseal starboard side of the outside hull amidships by passengers entrance. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Reseal with fiberglass the starboard side of bow as marked. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Repair hull just under the bow as marked. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Grind and reseal portside 1/3 forward of the under hull as marked. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Reseal with fiberglass the starboard side corner aft by transom above the water line. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Grind and reseal starboard side forward under vessel's registration number. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 30 March 2004
Resolved
Grind and reseal starboard side amidships under hull. as marked LEGACY COMPONENT DESC: Hull Plating
Documentation › Certificates/Documents
Issued 21 January 2004
Resolved
Provide evidence that the company is enrolled in a drug and alcohol consortium. LEGACY COMPONENT DESC: Proof of Consortium Enrollment (DAPI)
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 January 2004
Resolved
Label child size lifejackets stowage. LEGACY COMPONENT DESC: Storage
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 January 2004
Resolved
Provide Coast Guard or equivalent first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 21 January 2004
Resolved
Provide 2 B-II portable fire extinguishers.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 21 January 2004
Resolved
Provide 1 B-I portable fire extinguisher.
Engineering › Gasoline Engine (propulsion)
Issued 21 January 2004
Resolved
Replace fuel hose for the portable gasoline tank. LEGACY COMPONENT DESC: Fuel Line
Engineering › Bilge Water Management System
Issued 21 January 2004
Resolved
Provide visual indicator for the bilge pump. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 21 January 2004
Resolved
Provide visual and audible alarm for the bilge high level alarm at the operating station. LEGACY COMPONENT DESC: High level alarm
Accommodation/Occupational Safety › Occupational Safety
Issued 21 January 2004
Resolved
Provide 2 portable lights (flashlights). LEGACY COMPONENT DESC: Portable lights
Engineering › Bilge Water Management System
Issued 21 January 2004
Resolved
Provide a portable bilge pump of 5 GPM. LEGACY COMPONENT DESC: Pump
Accommodation/Occupational Safety › Occupational Safety
Issued 21 January 2004
Resolved
Provide safety chain or strong line, port and starboard, to protect open spaces between safety rails. LEGACY COMPONENT DESC: Deck Rail
Lifesaving › Lifejacket/PFD (General)
Issued 21 January 2004
Resolved
Provide donning placard for lifejackets. LEGACY COMPONENT DESC: Donning Placard
Construction/Loadline › Hull
Issued 21 January 2004
Resolved
Repair forward cleats, port and starboard. LEGACY COMPONENT DESC: Cleats
Electrical › Electric Supply System (service)
Issued 21 January 2004
Resolved
Provide a corrosion- resistant tray for main batteries with protective cover. LEGACY COMPONENT DESC: Battery Installation
Electrical › Electrical Distribution System (service)
Issued 21 January 2004
Resolved
Repair and remove obsolete electrical wires for space above pilot station. LEGACY COMPONENT DESC: Wiring
Engineering › Bilge Water Management System
Issued 21 January 2004
Resolved
Make operational or remove starboard bilge pump. Vessel only require 1 bilge pump aft. LEGACY COMPONENT DESC: Pump
Electrical › Electrical Distribution System (service)
Issued 21 January 2004
Resolved
Repair electrical supply system to bilge pumps so that the pumps are protected by a circuit breaker at the pilot station. LEGACY COMPONENT DESC: Circuit Breaker
Lifesaving › Hand Flares
Issued 21 January 2004
Resolved
Provide a brightly colored , portable waterlight container for the distress signals and marked " Distress Signals". LEGACY COMPONENT DESC: Storage
Electrical › Electrical Distribution System (service)
Issued 30 January 2003
Resolved
Remove all obsolete electrical wires and reconnected loose wires under the pilot station LEGACY COMPONENT DESC: Wiring
Lifesaving
Issued 30 January 2003
Resolved
Replace expired medication and provide mssing items from the first aid kit to include: eye wash solution, burn treatment compound, ammonia inhalants, and aspin tablets.
Lifesaving › Lifebuoys
Issued 30 January 2003
Resolved
Provide a 24" CG approved lifebuoy with a 60 feet dark color line, and attached to the waterlight via a quick release clip. LEGACY COMPONENT DESC: Quantity
Lifesaving › Lifebuoys
Issued 30 January 2003
Resolved
Provide bracket for lifebuoy. LEGACY COMPONENT DESC: Stowage
Documentation › Certificates/Documents
Issued 30 January 2003
Resolved
Make arrangement to obtain copy of the certificate from the Maritime drug testing consortium as soon as possible, and provide to Marine Inspector. ( Evidence of compliance for renewal to the consortium was verified via phone by Marine Inspector during this inspection. See Narrative for details)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 January 2002
Resolved
Portable bottle was missing discharge pin.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 January 2002
Resolved
Properly Install or mount portable fire extinguisher holding bracket..
Lifesaving › Hand Flares
Issued 22 January 2002
Resolved
Replace all expired hand flares ( 3 orange flares and 3 red flares).
Lifesaving › Buoyant Apparatus
Issued 22 January 2002
Resolved
Replace worn ring bouy line.
Lifesaving
Issued 22 January 2002
Resolved
Obtain complete First Aid Kit. LEGACY COMPONENT DESC: First Aid kit
Lifesaving › Lifejacket/PFD (Type II)
Issued 22 January 2002
Resolved
Install new reflector tape to 4 adult PFDs and to 3 children PFDs. LEGACY COMPONENT DESC: Reflector tape
Operations/Management › Drug and Alcohol Testing
Issued 22 January 2002
Resolved
Present proof that the desiganted vessel's master is part of company's Drug and Alcohol testing Program. LEGACY COMPONENT DESC: Master not listed in Company''s ltr.
Lifesaving
Issued 19 January 2001
Resolved
Write name of vessel on vessel's life ring.
Construction/Loadline
Issued 19 January 2001
Resolved
Properly intstall inoperative high water level alarm forward.
Documentation
Issued 19 January 2001
Resolved
Provide current training log book.
Lifesaving
Issued 19 January 2001
Resolved
Install instructions placard for downing of PFDs and safety instructions topassengers.
Lifesaving
Issued 19 January 2001
Resolved
Have on board, required red flares (3).
Construction/Loadline
Issued 3 February 2000
Resolved
REGLASS PORT AND STARBOARD TRANSOM UPPER CORNERS.
Construction/Loadline
Issued 3 February 2000
Resolved
REPLACE ROTTED WOOD IWO TRANSOM, UNDER/AROUND ENGINE MOUNT
Construction/Loadline
Issued 3 February 2000
Resolved
RE-ATTACH STARBOARD AFT CLEAT
Construction/Loadline
Issued 3 February 2000
Resolved
REPLACE ROTTED WOOD IWO INSIDE TRANSOM, PORT SIDE BOTTOM CORNER
Lifesaving
Issued 19 January 2000
Resolved
PROVIDE THREE(3) RED FLARES
Lifesaving
Issued 19 January 2000
Resolved
PROVIDE A COMPLETE FIRST AID KIT
Lifesaving
Issued 19 January 2000
Resolved
ATTACH PROPER LENGTH OF DARK LINE TO LIFERING AND FLOAT LIGHT.
Electrical
Issued 19 January 2000
Resolved
PROPERLY WIRE HIGH LEVEL BILGE ALARM
Electrical
Issued 19 January 2000
Resolved
PROPERLY WIRE ELECTRICAL BILGE PUMPS
Electrical
Issued 19 January 2000
Resolved
PROPERLY WIRE NAV LIGHTS
Lifesaving
Issued 19 January 2000
Resolved
PROVIDE FLOATLIGHT
Electrical
Issued 19 January 2000
Resolved
PROPERLY WIRE BATTERY TERMINAL
Fire Fighting
Issued 19 January 2000
Resolved
PROVIDE THREE (3) FIRE BUCKETS
Fire Fighting
Issued 12 January 1999
Resolved
PROVIDE THREE FIRE BUCKETS
Lifesaving
Issued 12 January 1999
Resolved
PROVIDE LIFEJACKET PLACARD/DONNING INSTRUCTIONS
Lifesaving
Issued 12 January 1999
Resolved
INSTALL REFLECTIVE TAPE IN RING BUOY
Construction/Loadline
Issued 12 January 1999
Resolved
INSTALL DOUBLE CLAMPS IWO BILGE PUMPS HOSES
Accommodation/Occupational Safety
Issued 12 January 1999
Resolved
INSTALL SAFETY HOOKS IN PORT/STARBOARD DOORS
Documentation
Issued 12 January 1999
Resolved
PROVIDE EVIDENCE OF FULLY COMPLIANT DRUG TESTING PROGRAM.
Documentation
Issued 12 January 1999
Resolved
PROVIDE CREW TRAINING LOG
Lifesaving
Issued 29 January 1998
Resolved
PROVIDE WATERPROOF CONTAINER TO STORE VISUAL DISTRESS SIGNALS. CONTAINER TO BE MARKED "DISTRESS SIGNALS".
Lifesaving
Issued 29 January 1998
Resolved
PROVIDE WATER PROOF CONTAINER FOR FIRST AID KIT CONTENTS
Engineering
Issued 29 January 1998
Resolved
RE-ROUTE OUTBOARD ENGINE'S POWER TRIM CABLE TO PREVENT FURTHER PINCHING.
Engineering
Issued 29 January 1998
Resolved
SECURE FUEL TANKS IN PLACE
Engineering
Issued 29 January 1998
Resolved
REPAIR THE REVERSE FUNCTION OF OUTBOARD ENGINE
Electrical
Issued 29 January 1998
Resolved
LABEL ELECTRICAL SWITCHES IN CONTROL STATION
Deck/Cargo
Issued 29 January 1998
Resolved
REPLACE WORN OUT ANCHOR CHAIN
Documentation
Issued 29 January 1998
Resolved
PROVIDE EVIDENCE OF DRUG TESTING
Construction/Loadline
Issued 20 January 1998
Resolved
RE-FASTEN SUPPORTS UNDER CENTER SITTING BENCH.
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE DELAMINATION ON THE PORT BUMPER GUARD
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE FORWARD PORTION OF PORT BUMPER GUARD
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE PORTION OF PORT SIDESHELL FORWARD, WHERE IT JOINS BOTTOM.
Construction/Loadline
Issued 20 January 1998
Resolved
SEAL AREA AROUND FORWARD TRAILER EYE BOLT
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE DELAMINATED PORTION OF STARBOARD BUMPER GUARD FORWARD
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE THE AFT SECTION OF STARBOARD SIDE BUMPER GUARD.
Accommodation/Occupational Safety
Issued 20 January 1998
Resolved
REPLACE BROKEN SAFETY CHAIN CONNECTORS ON PORT AND STARBOARD SIDES
Accommodation/Occupational Safety
Issued 20 January 1998
Resolved
RE-FASTEN PORT AND STARBOARD ENTRANCE DOORS
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND RELAMINATE UPPER EDGE OF TRANSOM.
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE 32 INCHES OF KEEL, FROM TRANSOM FORWARD
Construction/Loadline
Issued 20 January 1998
Resolved
GRIND OUT AND REGLAZE PORTION WHERE THE TRANSOM JOINS STARBOARD SIDE SHELL.
Electrical
Issued 20 January 1998
Resolved
SECURE WIRING FOR RADIO/CASSETTE PLAYER AND REMOVE UNUSED/DEAD WIRING FROM RADIO CONSOLE ABOVE CONTROL STATION
Documentation
Issued 20 January 1998
Resolved
PROVIDE COPY OF STABILITY LETTER
Accommodation/Occupational Safety
Issued 20 January 1998
Resolved
ATTACH CONNECTOR TO PORT AND STARBOARD DOORS TO ENSURE THEY REMAIN CLOSED
Accommodation/Occupational Safety
Issued 20 January 1998
Resolved
RE-FASTEN STARBOARD BOW INBOARD MIDDLE SAFETY RAILING.
Construction/Loadline
Issued 20 January 1998
Resolved
RE-FASTEN PIECE OF PLYWOOD LOCATED IN THE AFT SECTION OF CENTER SITTING BENCH
Electrical
Issued 20 January 1998
Resolved
REPLACE CRACKED POS BATTERY CABLE CONNECTOR
Electrical
Issued 20 January 1998
Resolved
REPLACE DAMAGED POS BATTERY CABLE
Electrical
Issued 20 January 1998
Resolved
SECURE POS/NEG BATTERY CONNECTORS
Electrical
Issued 20 January 1998
Resolved
SECURE BATTERY CABLES AROUND TERMINALS
Electrical
Issued 20 January 1998
Resolved
INSTALL MISSING LIGHT COVERS
Electrical
Issued 1 November 1995
Resolved
PLACE BATTERIES IN ACID RESISTANT BOX.
Fire Fighting
Issued 1 November 1995
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Accommodation/Occupational Safety
Issued 1 November 1995
Resolved
REMOUNT GATE HINGE, PORT SIDE FORWARD.
Electrical
Issued 1 November 1995
Resolved
INSTALL SECOND BATTERY.
Lifesaving
Issued 1 November 1995
Resolved
REPAIR OR RENEW WOOD PANEL ON FRONT SIDE OF CONTROL STATION.
Construction/Loadline
Issued 22 November 1994
Resolved
Install transom bolts with washers and nuts tightened.
Construction/Loadline
Issued 22 November 1994
Resolved
Replace 1 eight X four sheet of plywood along stbd side in way of impacted area at turn of chine.
Documentation
Issued 21 September 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 21 September 1993
Resolved
Provide documentation that a drug testing program that complies with 46 Code of Federal Regulations Part 16 is in place.
Documentation
Issued 26 October 1992
Resolved
Provide Coast Guard approved plans in accordance with 46 CFR 177.05-1._x001C_