Records from 1992 to 2005. Most recent: inspection, 12 January 2005.
Inspection history · 25
12 January 2005
ISM Exam · PII Safety Exam · ISPS III Exam · Loadline Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · ILO-147 Exam · Ballast Water Examination · STCW 95 Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2273450
10 January 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2272234
15 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2134287
13 July 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2164088
28 March 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2032657
10 June 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1628739
9 June 2002
Special Interest Vessel
Type not classified · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1628298
22 May 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 290338
21 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421708
8 April 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 402326
23 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 76536
20 October 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 396534
27 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389445
4 October 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 383390
13 February 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 375022
18 December 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 373374
2 September 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 370110
31 January 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 364176
4 December 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 529005
29 June 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 359136
10 May 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 465324
29 November 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 511540
10 October 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 529770
1 October 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 353617
1 October 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 353619
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 11 January 2005
Resolved
All of the Vessel's Fireman's Outfits were found to be in poor condition. Must be cleared to the satisfaction of Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 October 2009
Resolution: PSCO observed new in service firemans outfits.
Communications › Internal Communications System › Sound-powered Telephone
Issued 11 January 2005
Resolved
Crew failed to establish communications between Navigation Bridge and Emergency Steering Compartment during steering tests. Must be cleared to the satisfaction of Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 October 2009
Resolution: PSCO observed that proper comms. were established with the bridge.
Electrical › Electric Generation Source (emergency)
Issued 28 March 2004
Resolved
Emergency generator would not start automatically due to dead battery. Manual start only was possible. SOLAS CH. II-1 Reg 43.3.1 LEGACY COMPONENT DESC: Power Requirement
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2004
Resolved 28 March 2004
Resolution: Ship replaced battery and Emergency generator started automatically
Electrical › Electric Generation Source (emergency)
Issued 28 March 2004
Resolved
Replace battery for emergency generator. SOLAS CH. I-11.A
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2004
Resolved 28 March 2004
Resolution: Battery was replaced.
Electrical › Electric Generation Source (emergency)
Issued 28 March 2004
Resolved
Maintain 24 hour watch in emergency geneartor room while in U.S. waters.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2004
Resolved 28 March 2004
Resolution: Vessel replaced battery and generator starts automatically so 24 hour watch is no longer required.
Electrical › Electric Generation Source (emergency)
Issued 28 March 2004
Resolved
Were not able to automatically start emergency generator three consecutive times. SOLAS CH II-1 Reg 44.2 LEGACY COMPONENT DESC: Generator
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2004
Resolved 28 March 2004
Resolution: Emergency generator started automatically.
Lifesaving › Lifeboat Equipment
Issued 28 March 2004
Resolved
Port side lifeboat could not be deployed. SOLAS CH. 3 ,20.2 and CH.3 ,19.3.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2004
Resolved 28 March 2004
Resolution: Ship was able to deploy portside lifeboat.