← All vessels
DS SYMPHONY
DS SYMPHONY is a 2001 tank ship. The Coast Guard has recorded 11 inspections since 2002, most recently in August 2018, along with 9 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2002 to 2018. Most recent: inspection, 24 August 2018.
- Built
- 2001
- Last inspected
- 24 August 2018
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9249324 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8HH8
38058
Flag
LIBERIA
—
Maury page id
psix-38058
Inspections, by type
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it149995 - Dead Weight, Ton
172746 - Displacement, Ton
79525 - Convention (Subpart B), Gross Ton
47769 - Convention (Subpart B), Net Ton
172746 - Displacement, Ton
79525 - Convention (Subpart B), Gross Ton
47769 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
24 August 2018
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6513706
20 January 2011
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3925869
7 January 2010
COC-TVE Renew · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3660129
10 November 2008
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3358201
20 July 2007
ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2997010
15 January 2007
ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2855253
13 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2854865
16 May 2006
COC-TVE Annual · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2650596
14 February 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2584428
1 April 2005
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2321321
14 November 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1705874
Deficiency record · 9
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 24 August 2018
Resolved
Each tankship with a VCS must be fitted with a vapor pressure- sensing device which activates an alarm when the device measures a pressure of not more than 90% of the lowest pressure relief valve settings in the cargo tank venting system. The ships lowest pressure relief valve setting is 700mm/ng per the ships VECS manual. The high vapour pressure alarms should be set for not more than 90% of 700mm/ng, or 630mm/ng. The ships vapour alarm is set for 1260mm/ng, as listed on the ship generated instruction posted in the cargo control room. *Rectify prior to cargo operations*
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 24 August 2018
Resolved
The venting arrangements shall be so designed and operated as to ensure that neither pressure nor vacuum in cargo tanks shall exceed design parameters. The vessels VECS manual requires the ships cargo tanks to be protected from over pressure by pressure relief valves set at 700mm/ng. The ships crew have bypassed all individual P/V valves and have the common vapour pressure relief running to a breather valve at the mast riser set to 1100mm/ng *rectify prior to cargo operations*
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 August 2018
Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. The vessels cargo tank P/V vents & ballast tank vents are not fitted with appropiate flame screens.
Cargo tanks P/V vents: Slops (P&S), 7S, 6(P&S), 5(P&S), 4(P&S), 3(P&S), 2(P&S), 1S.
Wing ballast tanks vents: All except for 1 vent on 4S
*Rectify prior to cargo operations*
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 August 2018
Resolved
PSCO observed missing variable nozzles at 02 fire stations and missing spanner wrenches at 03 fire stations. *Rectify prior to cargo ops.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 August 2018
Resolved
PSCO observed 07 starboard tank gauging port leaking cargo vapors to the atmosphere. 07 starboard gauging port’s stop valve was defective. *Rectify prior to cargo ops.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 August 2018
Resolved
The high expansion foam concentrate storage tank has ship-generated instructions posted that conflict with the manufacturers instructions posted at the activation panel. Specifically the ships instructions require the user to activate the foam liquid pump in between the systems standby and discharge modes. The manufacturers instructions do not require the manual activation of the foam supply pump prior to discharge. Additionally the sequence of steps for the starting of the emergency fire pump and placing the system into standby mode are different on the 2 sets of instructions. *Rectify prior to cargo ops.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 24 August 2018
No resolution recorded
Vessel has not conducted 1.5 times MAWP test in over 3 years. Vessel shall be limited to maximum pressure of 9.9kg/cm2 until a 1.5 times MAWP test is conducted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 24 August 2018
Resolved
Vessel did not have MAWP marked; instead had test pressure marked on piping. *Rectify prior to cargo ops.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 1 April 2005
Resolved
1) Deficiency issued Vessel's Fire fighting ensambles were in a deteriated condition. Prior to 04 April 2005 have master send attestation that 4 new fire suits that meet SOLAS II-2 Reg 17 are on board.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.