MAURY USCG vessel records Sign in
← All vessels

STOLT HILL

STOLT HILL is a 1992 tank ship. The Coast Guard has recorded 43 inspections since 1992, most recently in March 2010, along with 23 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1992 to 2010. Most recent: inspection, 9 March 2010.

Built
1992
Last inspected
9 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8819093 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
380774
Flag
CAYMAN ISLANDS
—
Maury page id
psix-380774

Inspections, by type

…with no type recorded23
Years with a record 16 calendar years (1992–2010)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13088 - Convention (Subpart B), Net Ton
40160 - Dead Weight, Ton
49588 - Displacement, Ton
22620 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

VELEBIT Freight Ship · MISLE 367186 · 12 May 2002 · activity 1627706

Inspection history · 43

9 March 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3692826
8 January 2010 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3657281
29 July 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3549739
3 December 2008 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3373103
8 February 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3144322
7 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3143239
6 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3145003
30 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3139029
9 January 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Annual · Ballast Water Examination · MARPOL Annex II Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3123373
11 November 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2531106
8 November 2005 ISM Exam · Deficiency Check · MARPOL Annex V Examination · MARPOL Annex II Examination · MARPOL Annex I Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2530561
21 December 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2263108
4 August 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2155886
11 May 2004 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2065107
5 March 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139535
21 May 2003 Certificate of Compliance
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1798308
25 October 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1696096
22 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694647
22 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694823
10 October 2002 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1688031
18 September 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1677921
23 May 2002 Permit to Proceed
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1620071
22 May 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1619259
12 May 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1627706
19 April 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1605971
16 October 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 282916
16 October 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1057285
24 July 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 431084
24 July 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1106163
25 January 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 411866
14 January 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 785055
17 January 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 399416
17 January 1997 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102132
11 January 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 386773
11 January 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 874635
4 May 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 449637
14 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 373300
14 December 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1396214
16 December 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1161871
10 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 363258
10 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389732
16 December 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 502072
12 December 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826676

Deficiency record · 23

Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 8 January 2010 Resolved
Vessel's Inert Gas Generator (IGS) in not operational due to faulty oxygen analyzer. At this time vessel is not carrying any cargoes that require the use of IGS. Vessel is equipped additionally with nitrogen generator and nitrogen bottles. Provide class report attesting to proper operation of the IGS prior to use
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 8 March 2010
Resolution: Received, reviewed and accepted class report from DNV addressing the deficiency. 01 Special note was added.
Engineering › Sea-water System (primary cooling) › Pump
Issued 8 February 2008 Resolved
Master/ Chief Engineer confirmed bridge lost control of main engine due to the Sea Water Cooler malfunction in main engine cooling system.
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 8 February 2008
Resolution: Received class report from DNV satisfying requirement.
Engineering › Compressed Air System (control) › Valve
Issued 8 February 2008 Resolved
Air cylinder is a part of main engine maneuvering control for the fuel oil during forward and reversing operation. Cracks were found in the cylinders pertaining to 3 & 5 main engine units.
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 8 February 2008
Resolution: Both air cylinders for fuel oil control pertaining to 3 & 5 of the main engine units were renewed with new spares from ship inventory by engine crew.
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 November 2005 Resolved
Replace wasted soft patched fresh water piping adjacent water tank. To the satisfaction of the classification society
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 8 November 2005 Resolved
Repair damaged rope store vent. Rectify deficiencies prior to next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2005
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 8 November 2005 Resolved
vessel is to report all Non-conformities as per SMS in place( generator items ,etc) and fax copy to Coast Guard prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 November 2005 Resolved
Emergency generator lower and upper radiator hoses are leaking or are old and brittle one has electrical tape being used as a temporary patch. Replace upper and lower radiator hose prior to leaving port to the satisfaction of the classification society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 November 2005 Resolved
Emergency generator oil line from engine to oil filter housing leaking at hose. Have classification society determine if hoses are beyond service life and replace if needed SOLAS 74 Rectify deficiency prior to departure to the satisfaction of the classification society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 November 2005 Resolved
Emergency generator fuel system is leaking around banjo fittings, staining around area shows this is a long term leak. One fuel line from filter housing to isolation valve appears to be leaking at hose fitting. Clean area and determine where fuel leaks are coming from. Replace Banjp gaskets and test to satisfaction of the classification society prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 November 2005 Resolved
Salt water cooling pump to Generator cooling condenser has hose clamp soft patch on discharge side of pump. Have classification society inspect repair and make recommendation for permanent repair prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 8 November 2005 Resolved
Ventilation ducting from Stbd locker to outside has been replaced with PVC piping and attached with hose clamps. Have classification society survey to ensure correct materials for application. Rectify deficiency prior to next US port after sailing foreign to the satisfaction of the classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2005
Engineering › Bilge Water Management System › Piping
Issued 8 November 2005 Resolved
Vsls class is to approve status of reapir made to sea-water ejector piping. (soft/paptches/double patches)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2005
Electrical › Electrical Distribution System (service)
Issued 11 May 2004 Resolved
220V A/C electrical distribution system has a dead ground. Locate, isolate and repair ground. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 23 May 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 May 2004 Resolved
Main propulsion engine, cylinders No. 2 and 5 high pressure injection pump valves have notable leaks. LEGACY COMPONENT DESC: Cylinder
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 23 May 2004
Resolution: Received satisfactory class report.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 11 May 2004 Resolved
Cargo tanks No. 1C, 2P, 4P&S, and 6P P/V valves tank pressure monitoring transmitter do not function as per design. LEGACY COMPONENT DESC: P/V Valves
Action required: 705 - Other - as specified
Due 25 May 2004
Resolved 4 August 2004
Resolution: Received satisfactory class report.
Navigation › Collision/Grounding Avoidance
Issued 18 September 2002 Resolved
Repair radar prior to next U.S. port IAW 33 CFR 164.37(a). LEGACY COMPONENT DESC: Radar
Action required: 15 - Rectify deficiencies by next port
Due 19 September 2002
Resolved 10 October 2002
Resolution: Received technician report via fax indicating satisfactory repairs have been made to the radar.
Navigation › Collision/Grounding Avoidance
Issued 19 April 2002 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2002
Resolution: Received Class Survey Report from agent.
Deck/Cargo
Issued 16 October 2000 Resolved
IGG O2 ANALYZER INOPERABLE. PROVE PROPER OPERATION PRIOR TO OPERATING SYSTEM TO THE SATISFACTION OF CLASS PRIOR TO 16JAN01.
Condition: Unknown
Due 2 November 2000
Resolved 2 November 2000
Lifesaving
Issued 11 January 1996 Resolved
VESSEL LOST 3 RING BUOYS (1 EQUIPPED WITH LIGHT) OVERBOARD DURING TRANSATLANTIC CROSSING IN FOUL WEATHER.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 11 January 1996 Resolved
VESSEL LOST ONE FOC'SLE MOUNTED 6-MAN LIFERAFT OVERBOARD DURING TRANSATLANTIC CROSSING IN FOUL WEATHER.
Condition: Unknown
Due 12 January 1996
Resolved 20 February 1996
Deck/Cargo
Issued 12 December 1992 Resolved
REPLACE BROKEN NITROGEN ANALYZER FLASK FOR THE IGS.
Condition: Unknown
Due 12 December 1992
Resolved 12 December 1992
Navigation
Issued 12 December 1992 Resolved
PROVE PROPER OPERATION OF SATCOM.
Condition: Unknown
Due 12 December 1992
Resolved 12 December 1992
Deck/Cargo
Issued 12 December 1992 Resolved
PRIOR TO CARRYING CARGOES REQUIRING INERTING, MOVE PROPER OPERATION OF THE INERT GAS SYSTEM, TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 December 1992
Resolved 12 December 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.