← All vessels
BALTIC PERFORMER
BALTIC PERFORMER is a 1992 freight ship. The Coast Guard has recorded 32 inspections since 1992, most recently in December 2025, along with 8 deficiencies and 3 operational controls.
Records from 1992 to 2025. Most recent: inspection, 2 December 2025.
- Built
- 1992
- Last inspected
- 2 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9016674 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6EQ6
380777
Flag
BAHAMAS, THE
—
Maury page id
psix-380777
Inspections, by type
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it10381 - Convention (Subpart B), Gross Ton
5253 - Convention (Subpart B), Net Ton
16958 - Displacement, Ton
10603 - Dead Weight, Ton
5253 - Convention (Subpart B), Net Ton
16958 - Displacement, Ton
10603 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 32
2 December 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8276078
26 February 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7870062
16 March 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7651756
10 January 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7378115
22 February 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7143947
31 January 2020
Administrative Inspection · PSC B · COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6900091
30 January 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6900031
29 November 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6317091
3 January 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4217388
27 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4212895
3 January 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3920365
28 August 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3297589
28 August 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3313430
20 August 2008
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3304421
17 August 2008
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3304425
14 August 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3298128
3 November 2004
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2233873
26 November 2003
Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1953293
27 March 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598316
25 October 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294884
1 December 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 435210
20 November 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 422779
17 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 412852
28 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399846
28 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399990
6 August 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 393713
28 December 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 385793
24 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 511721
5 November 1994
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 372145
30 April 1994
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 366532
25 April 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486074
6 October 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 485674
Deficiency record · 8
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 January 2022
Resolved
The Machinery, associated piping systems and fittings shall be a design and construction adequate for the service for which they are in tended and protect as to reduce to a minimum any danger to persons on board due regard being paid to moving parts. PSCO observed exposed moving comppressor belts on two compressors which are a personnel entaglement hazard. 74SOLAS(04)con 11-1/26.1
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 10 January 2022
Resolved
The condition of the ship and it's equipmentshall be maintained to conform with the provisions of the present requlations to ensure the the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed 2 patches on #1 sanitary pump.74SOLAS(20)con 1/11
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2021
Resolved
"The condition of the ship and it's equipment shall be maintained to conform with the provisions of the presetn regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board."
Identified 02 heaters improperly hardwired into breakers of the #1 Cargo Refrigeration saltwater cooling pump and Eng Room Overhead Crane.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 February 2021
Resolved
"Doors required to be self-closing shall not be fitted with hold-back hooks."
Identified all self-closing doors in galley had unauthorized hold-back devices.
Navigation › Piloting/Steering › Marine Charts
Issued 3 January 2012
Resolved
Nautical charts and publications necessary for the intended voyage, shall be adequate. Vessel did not have chart for local area on board.
Solas 74' (09 cons.) CH V Reg 27 10(c)
Lifesaving › Inflatable Liferafts › Painter
Issued 3 January 2012
Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. The painter lines on all three 16 man liferafts were tied off to the ship, not the weak link as specified in the Code.
Solas 74 (09 Cons.) CH III Reg 34 / LSA CH IV 4.1.6.1 10(c)
Navigation › Collision/Grounding Avoidance › Radar Plotting Facilities
Issued 3 November 2004
Resolved
Upon inspection of required ARPA, observed that it was not operating properly. While the vessel did notify the CG on NOA, the ARPA was broken and the vessel did not request a Letter of Deviation to Operate in U.S. waters without required equipment. Issued COTP 04-157 and Letter of Undertaking in the amount of $32,500.
Unknown
Issued 28 December 1995
Resolved
HYDRO TEST BUNKER PIPING TO MAXIMUM ALLOWABLE WORKING PRESSURE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.