MAURY USCG vessel records Sign in
← All vessels

BALTIC PERFORMER

BALTIC PERFORMER is a 1992 freight ship. The Coast Guard has recorded 32 inspections since 1992, most recently in December 2025, along with 8 deficiencies and 3 operational controls.

Records from 1992 to 2025. Most recent: inspection, 2 December 2025.

Built
1992
Last inspected
2 December 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9016674 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
380777
Flag
BAHAMAS, THE
—
Maury page id
psix-380777

Inspections, by type

…with no type recorded18
Years with a record 21 calendar years (1992–2025)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10381 - Convention (Subpart B), Gross Ton
5253 - Convention (Subpart B), Net Ton
16958 - Displacement, Ton
10603 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

2 December 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8276078
26 February 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7870062
16 March 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7651756
10 January 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7378115
22 February 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7143947
31 January 2020 Administrative Inspection · PSC B · COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6900091
30 January 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6900031
29 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6317091
3 January 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4217388
27 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4212895
3 January 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3920365
28 August 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3297589
28 August 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3313430
20 August 2008 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3304421
17 August 2008 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3304425
14 August 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3298128
3 November 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2233873
26 November 2003 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1953293
27 March 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598316
25 October 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294884
1 December 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 435210
20 November 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 422779
17 February 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 412852
28 January 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399846
28 January 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399990
6 August 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 393713
28 December 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 385793
24 April 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 511721
5 November 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 372145
30 April 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 366532
25 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486074
6 October 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 485674

Deficiency record · 8

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 January 2022 Resolved
The Machinery, associated piping systems and fittings shall be a design and construction adequate for the service for which they are in tended and protect as to reduce to a minimum any danger to persons on board due regard being paid to moving parts. PSCO observed exposed moving comppressor belts on two compressors which are a personnel entaglement hazard. 74SOLAS(04)con 11-1/26.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 January 2022
Resolved 17 March 2023
Resolution: Deficiency rectified and received class report attesting to additional protection devices installed on moving compresser belts.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 10 January 2022 Resolved
The condition of the ship and it's equipmentshall be maintained to conform with the provisions of the present requlations to ensure the the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed 2 patches on #1 sanitary pump.74SOLAS(20)con 1/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 January 2022
Resolved 17 March 2023
Resolution: Deficiency rectified. Received class report attesting to the replacement of the santitary pump pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2021 Resolved
"The condition of the ship and it's equipment shall be maintained to conform with the provisions of the presetn regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board." Identified 02 heaters improperly hardwired into breakers of the #1 Cargo Refrigeration saltwater cooling pump and Eng Room Overhead Crane.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2021
Resolved 22 February 2021
Resolution: Ship's force rectified on the spot and removed improperly installed heaters.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 February 2021 Resolved
"Doors required to be self-closing shall not be fitted with hold-back hooks." Identified all self-closing doors in galley had unauthorized hold-back devices.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 February 2021
Resolution: Ship's force rectified all self-closing doors held-back in galley.
Navigation › Piloting/Steering › Marine Charts
Issued 3 January 2012 Resolved
Nautical charts and publications necessary for the intended voyage, shall be adequate. Vessel did not have chart for local area on board. Solas 74' (09 cons.) CH V Reg 27 10(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2012
Resolved 3 January 2012
Resolution: Agent brought local chart to vessel prior to departure.
Lifesaving › Inflatable Liferafts › Painter
Issued 3 January 2012 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. The painter lines on all three 16 man liferafts were tied off to the ship, not the weak link as specified in the Code. Solas 74 (09 Cons.) CH III Reg 34 / LSA CH IV 4.1.6.1 10(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2012
Resolved 3 January 2012
Resolution: Painter was tied to weak link.
Navigation › Collision/Grounding Avoidance › Radar Plotting Facilities
Issued 3 November 2004 Resolved
Upon inspection of required ARPA, observed that it was not operating properly. While the vessel did notify the CG on NOA, the ARPA was broken and the vessel did not request a Letter of Deviation to Operate in U.S. waters without required equipment. Issued COTP 04-157 and Letter of Undertaking in the amount of $32,500.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2004
Resolution: [name withheld] of Mackay Communications, Jacksonville, FL, completed work order 284198, repairing ARPA to full operation. Vessel faxed work order to JACMS.
Unknown
Issued 28 December 1995 Resolved
HYDRO TEST BUNKER PIPING TO MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.