← All vessels
CORNWALL
CORNWALL is a 1992 tank ship. The Coast Guard has recorded 38 inspections since 1992, most recently in June 2012, along with 23 deficiencies and 4 operational controls.
Records from 1992 to 2012. Most recent: operational control imposed, 18 June 2012.
- Built
- 1992
- Last inspected
- 18 June 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9005508 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8ZF7
380817
Flag
LIBERIA
—
Maury page id
psix-380817
Inspections, by type
…with no type recorded21
Years with a record
15 calendar years (1992–2012)
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4774 - Convention (Subpart B), Net Ton
25452 - Dead Weight, Ton
11361 - Convention (Subpart B), Gross Ton
25452 - Dead Weight, Ton
11361 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 38
18 June 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4347712
25 July 2011
Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4071409
24 July 2011
ISPS I Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4071440
24 July 2011
Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 4092685
23 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3797446
20 July 2009
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3540346
3 October 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3072238
1 July 2003
Certificate of Compliance · MARPOL Annex I Examination · MARPOL Annex V Examination · Letter of Compliance (Initial/Renewal)
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1831026
3 October 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 282834
23 May 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 278384
11 May 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 277778
18 February 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 275135
18 February 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 816193
18 February 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 817420
11 December 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 436077
25 January 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 425023
25 January 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 789641
25 January 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 817426
14 December 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 452219
8 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 421291
8 October 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 802264
8 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 802298
11 September 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 463008
26 January 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400033
26 January 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1102001
8 May 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 390955
8 May 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1082775
14 June 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 379375
21 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 374404
21 January 1995
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 832738
21 January 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 872706
11 October 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 440674
1 February 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1359697
25 October 1993
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 361965
22 October 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1134472
3 February 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 356266
15 January 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 832931
14 October 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1269477
Deficiency record · 23
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 18 June 2012
Resolved
Rudder angle indicator damaged, cause unknown.
Fire Fighting › Water Fog Applicators › Condition
Issued 24 July 2011
Resolved
Deck Spray System should be capable of covering all required areas with a uniformly distributed water spray. Several nozzles specifically over cargo domes 1 and 2 and piping in between distributed little or no water during routine test of the system.
per code for construction and equipment of ships carrying liquefied gases in bulk XI 11.3.2
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 20 July 2009
Resolved
Vessel does not have a fully operational Emergency fire pump. Emergency Fire Pump could only produce 2.0 bar at the pump and therefore could not maintain the required 2.7 bar at the Hydrant.
SOLAS 83 ammendments Ch II-2 Reg 4.3.3.2.2
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 20 July 2009
Resolved
Vessel fixed gas detection system was calibrated to alarm at 50 percent of lower flammable limit. IGC 1983 ed Ch 13.6.10
Vessel must calibrate fixed gas detection system to alarm at 30 percent LEL as required.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 20 July 2009
Resolved
The vessel does not have pressure testing equipment onboard. Vessel had no means of testing the operation of the required pressure alarms prior to conducting cargo operations. IGC 1983 Ed Ch18.7 Prior to conducting cargo operations demonstrate the proper operation of the pressure alarms.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 20 July 2009
Resolved
The Pressure gauge in the cargo control room for the #2 Cargo tank is inoperable. The Pressure gauge on the #2 Cargo Tank read -1.05 bar. All three cargo tanks are connected by a common vapor line and should therefore show common Pressures. IGC Code 1983 ed Reg 13.4.1. Repair or replace the pressure gauge to the satisfaction of the certificate issuing authority.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 1 July 2003
Resolved
Sprinker piping on free-fall lifeboat was damaged and covered with what appeared to be repair tape. Issued requirement for the vessels class society to attest to proper operation and repairs of water spray system.
Navigation
Issued 23 May 2000
Resolved
PRIOR TO DEPARTURE PROVIDE TECH REPORT FOR 3CM RADAR FAILURE.
Navigation
Issued 23 May 2000
Resolved
PRIOR TO 24JUN00 PROVIDE TECHNICAL REPORT ADDRESSING 3-4 DEGREE ERROR FOR MASTER GYRO.
Electrical
Issued 18 February 2000
Resolved
REPLACE INOPERABLE LIGHT IN FOWARD LIFEJACKET LOCKER PRIOR TO 25 FEB 00.
Lifesaving
Issued 18 February 2000
Resolved
REPAINT VESSEL NAME ON STARBOARD SIDE FOWARD LIFE RING PRIOR TO DEPARTURE.
Fire Fighting
Issued 18 February 2000
Resolved
PROVIDE BOLTS FOR INTERNATIONAL SHORE CONNECTION PRIOR TO DEPARTURE.
Electrical
Issued 18 February 2000
Resolved
PROVIDE ELECTRICAL MATTING IN FRONT OF MULTISTARTER PANEL NO.5 PRIOR TO 18 MAR 00
Deck/Cargo
Issued 18 February 2000
Resolved
PROVIDE PIN/STUD IN VCS HEADER TO PREVENT CARGO HOSE HOOK UP, AND PROVIDE CLASS APPROVAL FOR VAPOR CONTROL SYSTEM PRIOR TO 18 MAR 00
Construction/Loadline
Issued 8 October 1998
Resolved
REPAINT LOADLINE MARKINGS WHERE WORN PRIOR TO ENTERING NEXT U.S. PORT.
Lifesaving
Issued 8 October 1998
Resolved
REPAINT NAME AND HOMEPORT ON A FEW RING BUOYS THAT ARE WORN PRIOR TO ENTERING NEXT U.S. PORT.
Deck/Cargo
Issued 8 October 1998
Resolved
PROVE PROPER OPERATION OF IGS ALARMS TO SATISFACTION OF CLASS SURVEYOR PRIOR TO UTILIZING SYSTEM FOR REQUIRED CARGOES.
Fire Fighting
Issued 8 October 1998
Resolved
REPLACE FIRE HOSE NOZZLES OF THE SINGLE STRAIGHT STREAM TYPE WITH DUAL PURPOSE FOG SPRAY/JET STREAM TYPE PRIOR TO ENTERING NEXT U.S. PORT.
Electrical
Issued 8 October 1998
Resolved
PROVE PROPER OPERATION/CLOSURE OF VENT TO EMERGENCY GENERATOR ROOM PRIOR TOENTERING NEXT U.S. PORT.
Fire Fighting
Issued 26 January 1997
Resolved
Provide documentation from class that inert gas generator operates properlyprior to loading cargoes requiring operation of system or prior to 15 FEB 97.
Deck/Cargo
Issued 21 January 1995
Resolved
PRIOR TO NEXT U.S. PORT CORRECT LEAKING OIL TIGHT SEAL IN WAY OF NO. 1 CARGO COMPRESSION UNIT TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL_x001C_ COAST GUARD WITH SATISFACTORY SURVEYOR'S REPORT.
Electrical
Issued 21 January 1995
Resolved
PLUG OPENED CONNECTION PORT ON SIDE OF EXPLOSION PROOF LIGHT FIXTURE IN WAYOF STARBOARD SIDE MAIN DECK FORWARD OF ELECTRICAL MOTOR ROOM.
Accommodation/Occupational Safety
Issued 21 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE PROVIDE DOCUMENTATION ATTESTING TO U.S.C.G. APPROVAL OF MARINE SANTITATION DEVICE AS PER 33 CFR 159.7(b), OVERBOARD DISCHARGE TO BE SECURED IN INTERIM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.