Records from 1993 to 2008. Most recent: inspection, 23 August 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
23 August 2008
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3306351
21 January 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 399633
21 January 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1104827
11 July 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 380375
11 July 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 883659
12 November 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 372240
30 April 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 366440
30 April 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1396096
22 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365403
5 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 693560
4 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 440503
11 September 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 453062
5 August 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 105027
18 April 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1145911
Engineering
Issued 21 January 1997
Resolved
MAKE PERMANENT REPAIRS TO INOPERABLE OILY WATER SEPERATOR._x001C_ PRIOR TO NEXT U.S. PORT_x001C_ PROVIDE SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD_x001C_ MARPOL 73/78, AX.1/16_x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 21 January 1997
Resolved
PROVIDE 1997 CURRENT TIDE TABLES AND TIDAL CURRENTS TABLES_x001C_ PRIOR TO NEXT U.S. PORT_x001C_ SOLAS 74, V/20, (ALL SHIPS)_x001C_ _x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1997
Resolved
PROVIDE NEW EPIRB BATTERY WITH RELATED SERVICING_x001C_ PRIOR TO NEXT U.S. PORT_x001C_ SOLAS 74, AMND IV/7,(ALL SHIPS)_x001C_ _x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 January 1997
Resolved
MAKE REPAIRS TO MARINE SANITATION DEVICE DISCHARGE PUMP._x001C_ PRIOR TO NEXT U.S. PORT_x001C_ 33 C.F.R. 159.7_x001C_ _x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1997
Resolved
PROVIDE NON-CONDUCTIVE MAT AT EMERGENCY GENERATOR SWITCHBOARD_x001C_ PROVIDE A COPY OF CLASS REPORT TO LOCAL U.S. COAST GUARD_x001C_ PRIOR TO NEXT U.S. PORT_x001C_ SOLAS 92, II-1, REG.45_x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1997
Resolved
HAVE SCBA'S EXPERTLY SERVICED_x001C_ PROVIDE U.S. COAST GUARD WITH SERVICING REPORT_x001C_ PRIOR TO NEXT U.S. PORT_x001C_ IGC REG.14.2.6_x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 21 January 1997
Resolved
MAKE NECESSARY REPAIRS/PROVE PROPER OPERATIONS OF INERT GAS SYSTEM. _x001C_ PRIOR TO NEXT U.S. PORT_x001C_ IGC 9.3_x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 21 January 1997
Resolved
HAVE CARGO LIQUID PIPING RELIEF VALVES TESTED_x001C_ PROVIDE U.S. COAST GUARD WITH TEST REPORT_x001C_ PRIOR TO NEXT U.S. PORT_x001C_ 46 C.F.R. 154.1517_x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 21 January 1997
Resolved
PROVIDE ONBOARD ORIGINAL SAFE MANNING DOCUMENT._x001C_ PRIOR TO NEXT U.S. PORT_x001C_ IMO RESOL A.48 (XII)_x001C_
Condition: Unknown
Due 21 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 11 July 1995
Resolved
Prove proper operation of Lifeboat engine by next U.S. port.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Navigation
Issued 11 July 1995
Resolved
VESSEL IS MISSING CHART #25677 OR FORIEGN EQUIVALENT OF GUAYAMA HARBOR.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Documentation
Issued 30 April 1994
Resolved
VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES READILY AVAILABLE AT BUNKERING STATIONS, NOR HAVE A LINE DIAGRAM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1994
Resolved 23 November 1994