MAURY USCG vessel records Sign in
← All vessels

UNION CONFIDENCE

UNION CONFIDENCE is a 1984 freight ship. The Coast Guard has recorded 15 inspections since 1992, most recently in November 2001, along with 17 deficiencies — 1 with no resolution recorded —.

Records from 1992 to 2001. Most recent: inspection, 28 November 2001.

Built
1984
Last inspected
28 November 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8207226 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
381248
Flag
MALTA
—
Maury page id
psix-381248

Inspections, by type

…with no type recorded14
…past their stated due date1
Years with a record 8 calendar years (1992–2001)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6611 - Regulatory (Subpart C or D), Net Ton
18375 - Dead Weight, Ton
12510 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

28 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295867
23 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295739
2 November 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 295243
20 December 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 435963
16 May 1997 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 403702
16 May 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403753
20 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394540
20 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 22849
17 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 375468
12 January 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1426858
10 January 1994 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 529834
19 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 524406
19 October 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353843
18 October 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353968
3 October 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 353762

Deficiency record · 17

Electrical
Issued 23 November 2001 Resolved
HYDRAULIC OIL LEAKS ORIGINATING FROM SECONDARY STARTING SYSTEM FOR EMERGENCY GENERATOR SET. SOLAS 74 2001 AMEND CHP I REG 11(a).
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Electrical
Issued 23 November 2001 Resolved
SECONDARY MEANS OF STARTING THE EMERGENCY GENERATOR SET, HYDRAULIC IS UNABLE TO PROVIDE MEANS OF STARTING GENERATOR SET. SOLAS 74 81 AMEND CHP II-I REG 44.2
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Deck/Cargo
Issued 2 November 2001 Resolved
CLASS TO SURVEY LARGE DENT IN CARGO HOLD #4 IWO FRAME #54 ABOVE HFO TANK #4CENTER.
Condition: Unknown
Due 2 November 2001
Resolved 11 November 2001
Fire Fighting
Issued 2 November 2001 Resolved
CLASS TO DETERMINE IF WOOD DOOR TO EMERGENCY GENERATOR IS ACCEPTABLE. _x001C_ CLASS DETERMINED THAT WOOD DOOR TO EMERGENCY GENERATOR ROOM TO BE_x001C_ REPLACED PRIOR TO NEXT ANNUAL SURVEY
Condition: Unknown
Due 21 August 2002
Resolved 11 November 2001
Lifesaving
Issued 2 November 2001 No resolution recorded
REPLACE/RENEW PROTECTIVE COVER TO EMERGENCY GENERATOR FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 2 December 2001 — due date passed with no resolution recorded
Lifesaving
Issued 2 November 2001 Resolved
VESSEL TO ADD MORE PROTECTIVE GRADING IN STEERING GEAR ROOM TO PREVENT SLIPS,FALLS.
Condition: Unknown
Due 23 November 2001
Resolved 23 November 2001
Documentation
Issued 20 December 1999 Resolved
VESSEL'S OIL RECORD BOOK WAS NOT BEING SIGNED BY THE MASTER. MASTER WAS ADVISED.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 20 December 1999 Resolved
BOWSING TACKLE(FRAPPING LINES) NOT PROVIDED FOR DAVIT LAUNCHED LIFEBOATS ASREQUIRED BY SOLAS TRAINING MANUAL AND POSTED INSTRUCTIONS.
Condition: Unknown
Due 23 November 2001
Resolved 23 November 2001
Lifesaving
Issued 20 August 1996 Resolved
VESSELS LIMIT SWITCHES ARE INOPERABLE ON PORT AND STBD LIFEBOAT.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Lifesaving
Issued 20 August 1996 Resolved
VESSEL TO REPLACE ALL LIFEJACKET LIGHTS.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Deck/Cargo
Issued 17 February 1995 Resolved
ANCHOR WINDLASS REPORTED TO BE INOPERATIVE.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Navigation
Issued 17 February 1995 Resolved
VESSEL'S CHARTS FOR THE AREA TRANSITED, NOAA #11361, #11364, #11367, OR #11368, AND #11370 NOT CORRECTED.
Condition: Unknown
Due 3 March 1995
Resolved 21 February 1995
Unknown
Issued 17 February 1995 Resolved
THREE (3) OF VESSEL'S CREW MISSING MEDICAL EXAMINATIONS.
Condition: Unknown
Due 3 March 1995
Resolved 21 February 1995
Navigation
Issued 17 February 1995 Resolved
STEERING GEAR POWER FAILURE ALARM ON BRIDGE INOPERATIVE.
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Navigation
Issued 19 October 1992 Resolved
Vessels manuvering fact sheet did not contain all the required information.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Navigation
Issued 19 October 1992 Resolved
Vessels U.S. coastpilot vol 7 was not corrected to date.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Navigation
Issued 19 October 1992 Resolved
Vessel did not have a copy of the inland navigation rules onboard.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992

Ownership record