Registered dimensions (L × B × D)41.1 ft × 12.1 ft × 5.7 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNITED BOATBUILDERS, INC · BELLINGHAM, WA, UNITED STATES · built 1968
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN CITY, MD
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
13 May 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8372660
23 April 2026
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8352730
14 May 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8135322
6 May 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8129625
7 April 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8106384
15 April 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7888914
5 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7891798
17 May 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7693113
17 May 2022
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7393352
7 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7427373
12 August 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7285602
18 May 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7196695
27 July 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7026154
23 April 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6948388
15 May 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6719914
18 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6526398
2 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6402552
19 April 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6128412
14 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5980709
28 March 2016
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5900995
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2026
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Bilge pump in engine compartment does not operate is automatic operation or show operation via visual means.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2026
Resolution: Witnessed pump operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. High water alarm in forward compartment does not alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2026
Resolution: Witnessed alarm operation
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Portable fire extinguishers have not been annually inspected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 14 May 2026
Resolution: Witnessed completion of annual service
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Bilge pump in forward compartment does not operate is automatic operation or show operation via visual means.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 30 May 2025
Resolution: Recieved video evidence of proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Life ring had improper retro tape.
46 CFR 185.604(I)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 7 April 2025
Resolution: New reflective tape was added.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 May 2023
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
No drill records were available at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2023
Resolution: Drills were conducted and logged.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables,
Current Pubs were not onboard vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2023
Resolution: New publications were added on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 May 2023
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry Six hand red flare distress signals approved in accordance with § 160.021 and Six hand orange smoke distress signals approved in accordance with § 160.037. Vessel only had 4 red and 4 orange flares onboard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2023
Resolution: All proper flares were added to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 May 2023
Resolved
Each vessel certificated to operate on a limited coastwise route within three miles of land in cold water must be provided with the survival craft required and Be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Vessel's Life float needs to be replaced prior to cold water requirements start.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 May 2023
Resolution: New life float was purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers.
Bilge pump in forward compartment was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2023
Resolution: A new bilge pump was added.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 May 2021
Resolved
Life floats must have at least 12' pendants placed at intervals of at least 18" apart. Pendants on life float were frayed and unusable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 12 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 May 2021
Resolved
Life floats and life ring buoys must have type II retroreflective SOLAS tape. Vessel had DOT reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 12 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021
Resolved
Vessels must have at least one life ring buoy with a floating water light with a 3-6' lanyard. Vessel's life ring buoy did not have a water light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 12 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021
Resolved
Vessels must be equipped with a visual and audible indicator at the operating station for bilge alarm system. Vessel's alarm panel was incorrectly labled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 12 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 May 2021
Resolved
Vessel's must have adequate and up to date charts for intended voyages. Vessel's charts were last corrected in 2011.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 12 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 May 2019
Resolved
any vessel of at least five net tons must have a Certificate of Documentation. Vessel was unable to provide COD 46 CFR 67.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2019
Resolved 16 May 2019
Resolution: Vessel O/O provided original vessel COD
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 May 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 17 May 2019
Resolution: Vessel O/O provided copy of new FCC Station License for vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2019
Resolved
A Vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practible conditions. The Forward compartment bilge pump automatic float switch is inoperable. 46 CFR 182.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 16 May 2019
Resolution: Vessel O/O replaced float switch and proved proper operation to the attending MArine Inspector.