14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 13 August 2024
Resolved
Each towing vessel must be operated in compliance with each towing vessel must be capable of preventing all oil spills from reaching the water during transfers by: using fixed or portable containment off sufficient capacity to contain the most likely spill. All deck containment on board do not have a means to prevent a spill overboard. 46 CFR 140.655
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 25 June 2025
Resolution: Vessel added scupper plugs to deck containment areas.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 12 August 2024
Resolved
Each life float and rigid buoyant apparatus must be fitted with a life line, pendants, a painter, and floating electric water light approved under approval series 161.010. No paddles are required for this life float, however life float on board does not have electric water light and weak link tag was missing. 46 CFR 141.325
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 25 June 2025
Resolution: Vessel added new floating electric light and float free link certification identification tag.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 August 2024
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either; non-electric, phosphorescent adhesive lighting strip that are installed along escape routes and sufficiently visible to enable egress with no power. All living/berthing area exit doors do not have E-lighting or any phosphorescent adhesive strip to indicate route of egress. 46 CFR 143.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 25 June 2025
Resolution: Vessel added phosphorescent adhesive strips to the back of all living/berthing exit doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 August 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Interlock bar on switchboard that is designed to prevent energizing of both generator breakers at the same time gives way to malfunction as only 1/4 of an inch of the interlock bar prevents connection of both generator breakers. 46 CFR 143.400 (e)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 25 June 2025
Resolution: Vessel rectified interlock bar that will prevent activation of generator breakers at same time.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 27 February 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. The front cover of the main lighting panel in the engine room is protruding out, leaving a 3 inch gap. Secure panel cover.
46 CFR 143.400(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Dangerous areas
Issued 27 February 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The locking device on the main breaker panel PPT in the engine room is broken and requires a screwdriver to open. Replace locking device.
46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 February 2023
Resolved
Pressure vessels over 5 cubic feet, in volume and over 15 pounds per square inch maximum allowable working pressure (MWAP) must be equipped with an indicating pressure gauge (in a readily visible location). The pressure gauge on the receiver is inoperable. Replace pressure gauge in kind.
46 CFR 143.300
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 February 2023
Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. The VHF-FM was not outfitted with battery backup. Install battery backup.
46 CFR 140.715
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 27 February 2023
Resolved
The owner, managing operator, or master must ensure that all persons on board a towing vessel comply with the health and safety plan. Vessel did not have equipment outlined in their blood-borne pathogen hazards plan. Vessel must comply with plan.
46 CFR 140.500(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 27 February 2023
Resolved
The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Garbage placard was not displayed. Display placard in prominent location.
33 CFR 151.59(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 27 February 2023
Resolved
Each U.S. towing vessel of 26 feet (about 8 meters) or more in length, except a public vessel, must hold a ship-radio-station license for radio transmitters (including radar and EPIRBs), and each operator must hold a restricted operator's license or higher. Vessel operator did not hold a restricted operator's license. Obtain proper license.
33 CFR 164.72(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 26 April 2023
Resolution: Resolved to the satisfaction of the MI
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 February 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Vessel was missing a smoke detector. Install detector.
46 CFR 142.330(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 February 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Head did not contain internal emergency lighting. Add emergency lighting.
46 CFR 143.410(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 February 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room ventilation was not equipped with an easily accessible means for opening/closing. Ensure engine room ventilation has an emergency means for closing.
46 CFR 144.600
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 16 March 2023
Resolution: Resolved to the satisfaction of the MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 August 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Each towing vessel must be fitted with a general alarm that is activated at each operating station and can notify persons on board in the event of an emergency. During loss of power to the vessel, the general alarm is unable to activate. Demonstrate adequate alternate energy source for the general alarm during emergency operations following a loss of power to the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: MI witnessed general alarm during (loss of power - dark ship)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 August 2022
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil was found in the engine room bilge. Remove excessive oil accumulation to the satisfaction of a CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Bilge in engine room was free of excessive oil
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 August 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room exhaust stack openings do not have a closure device. Install closure device to satisfaction of CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Ventilation covers were installed over exhaust stack openings
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 August 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Two emergency lighting installations were not operational during a loss of power to the vessel. Ensure all emergency lighting installations are fully operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: MI's witnessed operation of emergency lighting during loss of power - dead ship
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 16 August 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to...: Vessel was missing required sections for the Health and Safety plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: MI's ispected Health Safety Manual,all topics listed in 46 CFR 140.510 were covered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 August 2022
Resolved
All pressure vessels must have the MAWP indicated by stamp, nameplate, or other means visible to the crew.
Control air receiver beneath the pilothouse missing the data plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Air receiver was properly labeled with data plate
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 August 2022
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: Every towing vessel of 7.8 meters (26 feet) or over in length, measured from end to end over the deck excluding sheer, while navigating. Vessel missing the FCC Bridge to Bridge certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: FCC bridge to bridge certificate onboard vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 August 2022
Resolved
The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Navigation equipment installed needs some kind pull proof installation at electrical plug outlets (also engine room equipment).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: MI visually inspected pull proff device at electrical plug outlet
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 August 2022
Resolved
Electrical equipment, piping for flammable or combustible liquid, seawater cooling, or fire-fighting systems must be provided with isolation devices and markings as follows: Color coding required by this section may be met by complying with coding standards contained in the ISO 14726:2008(E) (incorporated by reference, see § 136.112 of this subchapter), or in accordance with the TSMS applicable to the vessel. Portside fuel/oil tank vents missing color coding and/or labels. Vessel needs to color code or label port side tank vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Port tank vent properly labeled and color coded.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 16 August 2022
Resolved
Prior to getting underway for the first time on a particular towing vessel, each crew member must receive a safety orientation and be provided with health and safety information and training relevant to the normal operation and emergency duties required for each vessel. Did not have a crew member clearly identified acting as the deckhand. Identify crew members who will be regularly serving as deckhands and provide documentation of completed crew member orientation and emergency operations training.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Crew member orientation and emergency operations training updated. Highlighting emergency duties.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 16 August 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including potable water supply. Sinks were not properly labeled. Label sinks as not for human consumption.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Sinks labeled "Water not for human consumption"
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 August 2022
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Data plate on pressure vessel in the upper engine room space was painted over and unreadable. Clean data plate on pressure vessel in upper engine room space to identify proper MAWP.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Data plate cleaned and legible
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 August 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. Multiple daisy-chained extension cords and potentially unsafe electrical configurations including plug-in power strip near the galley sink were observed. Remove/reconfigure electrical cords to make permanent installations in accordance with safe industry standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: GFCI safe electrical configuration near galley sink
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 August 2022
Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection equipment complies with the applicable requirements and is in good working order. Smoke detectors were found to have expired batteries and testing of equipment during drills was not found. Replace batteries in smoke detectors to ensure proper operation and ensure that relevant sensors and equipment are tested and documented during fire drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: New smoke detectors installed
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 16 August 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including confined space entry. Fixed fire fighting storage space was not clearly identified. Label CO2 storage space to mitigate health and safety hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: MI witnessed labeling on CO2 storge space door
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 August 2022
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Remove expired items from first aid kit and remove any expired visual distress signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: 02 new first aid kits onboard vessel
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 August 2022
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crew members which includes display and distribution of informational material, community service hot-line telephone number for crew member assistance, and the employer's policy regarding drug and alcohol use in the workplace. Vessel needs to more clearly post EAP information for the availability of crew members.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: EAP information posted in galley for crew visibality
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 August 2022
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. Multiple glass lighting fixtures were found to be missing protective guards. Install protective guards per manufacturer design or replace glass bulbs with shatter resistant alternative.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2023
Resolution: Protective covers installed over glass lighting fixtures