MAURY USCG vessel records Sign in
← All vessels

YU LAN HAI

YU LAN HAI is a 1991 freight ship. The Coast Guard has recorded 33 inspections since 1992, most recently in August 2011, along with 11 deficiencies and 8 operational controls, 1 with no removal date recorded.

Records from 1992 to 2011. Most recent: inspection, 17 August 2011.

Built
1991
Last inspected
17 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8807210 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
381682
Flag
CHINA
—
Maury page id
psix-381682

Inspections, by type

…with no type recorded23
Years with a record 16 calendar years (1992–2011)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it35350 - Convention (Subpart B), Gross Ton
21472 - Convention (Subpart B), Net Ton
66044 - Dead Weight, Ton
75953 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

17 August 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4110266
12 January 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3652508
12 December 2008 MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3370310
24 September 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3065783
20 September 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3062118
21 May 2007 Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 2938752
28 April 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2917541
26 February 2007 Ballast Water Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2877539
26 February 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2877772
25 February 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2877261
25 February 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2877267
21 February 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2874895
23 November 2005 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2540072
29 September 2005 PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2503818
27 September 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2206715
24 September 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2204612
30 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2034065
8 August 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1658642
3 April 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1600763
23 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 275947
25 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426031
20 August 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 419390
20 December 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 145996
4 December 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 410458
21 March 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 401809
17 February 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 388271
16 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 376437
5 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 869360
25 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 368785
28 February 1994 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 364834
8 August 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 501845
30 December 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 355397
25 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 460192

Deficiency record · 11

Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 12 December 2008 Resolved
OIL FOUND ON OR NEAR #1 GENERATOR AND CONTROL BOX FOR F.O. SUPPLY UNIT (LOCATED IN PRUIFIER ROOM). PRODUCT IS IN SMALL POOLS ON THE DECK, COATING MACHINERY, AND ON LAGGING.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 December 2008
Resolution: DEFICIENCY CORRECTED ON SPOT. PRODUCT WAS CLEANED UP, MACHINARY WAS WIPED DOWN, AND LAGGING WAS REPLACED.
Construction/Loadline › Hull › Side Shell
Issued 12 December 2008 Resolved
SIDE SHEILL IS PUSHED IN ON PORT QUARTER. CREASE RUNS APPROX. 7 FT FORE AND AFT AND IS APPROX. 6 INCHES HIGH AND APPROX. 1.5 INCHES DEEP. 6TH FRAME AFT OF THE NO. 2 HFO SETTLING TANK IS PUSHED INBOARD, AS A RESULT OF THE DAMAGE. PROVIDE CLASS RPT EVALUATING STRUCTURAL DAMAGE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2009
Resolution: Vessel supplied class report requiring annual surveys of damage.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 November 2005 Resolved
Evidence of Leaking from Stbd Double Bottom Ballast Tank into #1 Cargo Hold. Suspect recent weld repair to support frame and or doubler plate from previous repair. Ballast Tank currently empty, thus unable to ascertain volume of leak. Vessel must repair to prior to loading cargo in Hold #1. SOLAS 97CONS II-1/25.9.1
Action required: 705 - Other - as specified
Due 23 November 2005
Resolved 24 November 2005
Resolution: Surveyor from China Classification Society attended the vessel @ 0100 hours and supervised repairs to affected area of #1 Cargo Hold. New weld was tested with full adjacent ballast tank.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 September 2005 Resolved
fire doors in stairway were not self closing
Condition: Improper/Lack of Maintenance
Due 30 September 2005
Resolved 30 September 2005
Resolution: Closing appliance was adjusted to close and latch the door. Deficiency cleared on the spot.
Electrical › Electric Supply System (service)
Issued 3 April 2002 Resolved
Remove misc. batteries from emergency generator room and place in suitable housing. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 7 August 2002
Resolution: Received proper documentation from vessel''s master stating all batteries have been removed and properly stored.
Pollution Prevention/Response › Prevention Equipment
Issued 3 April 2002 Resolved
Provide name plate placard and or paperwork for Marine Sanitation Device that attest to type and approval nlt 01May02. Complete to the satisfaction of the USCG. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 7 August 2002
Resolution: Received proper documentation that nameplate has been installed from [name withheld] stating the system is a type III MSD.
Fire Fighting
Issued 25 July 1994 Resolved
Tighten dresser coupling fire main port side holds 3 and 5.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Fire Fighting
Issued 28 February 1994 Resolved
The vessel's fire plan locations were not labeled.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Lifesaving
Issued 28 February 1994 Resolved
The vessel's life rafts did not have a weak link attached so as ensure thatthe raft is float free.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Documentation
Issued 28 February 1994 Resolved
33 C.F.R. 155.750 The vessel's oil transfer procedures were incomplete in that they only contained the procedures for tending mooring lines, topping off of tanks and the line diagrams. The procedures were also not in the order listed in 33 CFR 155.720 or cross-referenced.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Construction/Loadline
Issued 28 February 1994 Resolved
33 C.F.R. 155.450(a) The vessel which is 731.25 feet did not have a "Discharge of Oil Prohibited" Placard displayed in the machinery spaces.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994

Ownership record