Records from 1996 to 2005. Most recent: inspection, 10 July 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
10 July 2005
COC-TVE Renew · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2418385
23 February 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2297841
6 July 2004
COC-TVE Annual · ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2118736
18 December 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1966649
12 September 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1903573
20 May 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1797662
27 April 2003
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1781422
22 May 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1619425
19 April 2002
MARPOL Annex I Examination · Tank Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1603969
6 February 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1774723
1 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 286734
1 February 2001
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1058928
7 July 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 527749
22 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 391712
Construction/Loadline › Markings › Load Line Mark
Issued 6 July 2004
Resolved
Paint loadline marking in contrasting color. ICLL Annex I reg 8
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 23 February 2005
Resolution: RECIEVED STATEMENT FROM MASTER
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 6 July 2004
Resolved
Repair broken bonding strap on starboard vapor line. Solas 74 (amended) Chapter II-2 reg 59.
Action required: 705 - Other - as specified
Due 6 July 2004
Resolved 6 July 2004
Resolution: Starboard bonding starp was replaced prior to Coast Guard departure.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2004
Resolved
Prove proper lighting in engine room replace 20 missing or non working lights. Solas 74 (amended) chapter 1, reg 11(a)
Action required: 705 - Other - as specified
Due 6 July 2004
Resolved 6 July 2004
Resolution: Light bulbs were replaced all 20 bulbs in lamp fixtures.
Deck/Cargo › Holds/Tanks
Issued 27 April 2003
Resolved
The overfill alarms on cargo tanks 2P, 3P, 5S, 6S, and 7S do not work. Prove proper operation prior to loading any oil in U.S. waters. LEGACY COMPONENT DESC: Liquid Level Gauging
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 20 May 2003
Resolution: MSO LA/LB CLEARED. ALARMS TESTED SAT.
Engineering › Sea-water System (primary cooling)
Issued 27 April 2003
Resolved
The cargo pump sea water cooling line in the overhead by way of the main fire pumps has a temporary band clamp patch. LEGACY COMPONENT DESC: Cargo Pump line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2003
Resolved 12 September 2003
Resolution: New pipe section installed.
Engineering › Steam System (auxiliary)
Issued 27 April 2003
Resolved
The atmospheric steam condenser cooling water pump discharge line has two temporary band clamp patches. LEGACY COMPONENT DESC: Steam Condenser Cooling line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2003
Resolved 12 September 2003
Resolution: New pipe section installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 19 April 2002
Resolved
Make pumproom available for inspection
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2002
Resolved 20 April 2002
Resolution: Pumproom inspected, sat
Construction/Loadline › Structures
Issued 19 April 2002
Resolved
Install weathertight door in fwd. forecastle bow light space LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2002
Resolved 22 May 2002
Resolution: corrected
Pollution Prevention/Response › Prevention Equipment
Issued 19 April 2002
Resolved
Prove proper operation of the ODME
(Vessel had cargo in slop tanks and could not operate ODME) LEGACY COMPONENT DESC: Oily Mixture Discharge Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2002
Resolved 22 May 2002
Resolution: corrected
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 19 April 2002
Resolved
Make permanent repairs to the diesel day tank distribution valve IWO bas of day tank
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2002
Resolved 20 April 2002
Resolution: Valve replaced
Construction/Loadline
Issued 22 May 1996
Resolved
Vessel is not equipped with an Oily Water Separator with a 15 ppm alarm andshutoff (MARPOL 73/78, 1992 amendments to Annex I, paragraph 16).
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Deck/Cargo
Issued 22 May 1996
Resolved
Vessel Vapor control header not equipped with flange stud (46CFR39.20-1e).
Condition: Unknown
Due 10 July 1996