BELLE OF WASHINGTON is a 1993 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2016, most recently in December 2020, along with 13 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2020. Most recent: inspection, 15 December 2020.

Built
1993
Last inspected
15 December 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 December 2020
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8441
382084
Flag
UNITED STATES
Maury page id
psix-382084

Documentation record

Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
27 - Convention (Subpart B), Net Ton
39 - Regulatory (Subpart C or D), Gross Ton
91 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

15 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7111886
8 July 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7000896
2 November 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6573517
9 October 2018 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6553405
10 May 2018 Administrative Inspection · Excursion Permit · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6411512
1 February 2018 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6347991
17 October 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6285003
22 August 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5960703

Deficiency record · 13

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 December 2018 Resolved
Vessels hull has extensive corrosion.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2018
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 October 2018 Resolved
Vessels upper deck stowage box was damaged. Renew/repair upper deck life jacket stowage box and remark properly.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2018
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 October 2018 Resolved
MDE lube oil pressure gauge is inoperative. Trouble shoot, renew/replace/repair back to operational as designed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 October 2017 Resolved
Expired (31 Aug 2017) 3 trips with passengers after expiration date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2017
Resolution: Provided e-mail copy of valid COD.
Documentation › Certificates/Documents › FCC SSL
Issued 17 October 2017 Resolved
Provide FFC operators permit 47CFR80.159
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2017
Resolution: Provided e-mail copy of FCC Operators Permit for owner
Lifesaving › Hand Flares › Not on Board
Issued 17 October 2017 Resolved
Missing 2 hand red flares
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2017
Resolution: Owner provided receipt for new flares
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 October 2017 Resolved
Remove 3 type II child PFDs and replace with type I child PFDs
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 27 November 2017
Resolution: Owner provided receipt for life jackets
Construction/Loadline › Hull › Weld
Issued 17 October 2017 Resolved
4" crack on frame 1 stbd outboard side
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 1 December 2017
Resolution: Owner has welder weld crack and install unapproved bracket with bolts to reinforce frames. issue will be addressed at drydock in Feb. 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 October 2017 Resolved
Ring buoy life line needs to be replaced at pilot house and stern
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Ring buoy life lines replaced with new
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 October 2017 Resolved
Ring buoy life line needs to be installed around the body
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 27 November 2017
Resolution: Attached life line properly
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 October 2017 Resolved
Expired Meds
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Replaced expired meds.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 October 2017 Resolved
Replace all Fire Ext. brackets with approved brackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 29 November 2017
Resolution: Owner provided photos and receipt of mounting brackets.
Fire Fighting › Fire Pumps › Arrangement
Issued 22 August 2016 Resolved
Repair engine driven fire/bilge pump misalignment.
Due 22 September 2016
Resolved 17 October 2017
Resolution: Observed fire pump with SAT results.

Casualty record · 1

27 August 2011Routine · role: Involved in a Marine Casualty · activity 4133749
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record