MAURY USCG vessel records Sign in
← All vessels

BELLE OF WASHINGTON

BELLE OF WASHINGTON is a 1993 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1993, most recently in December 2020, along with 62 deficiencies and 1 casualty investigation in 2011.

Records from 1993 to 2020. Most recent: inspection, 15 December 2020.

Built
1993
Last inspected
15 December 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE8441
382084
Flag
UNITED STATES
367405530 (licence lapsed)
Maury page id
psix-382084

Inspections, by type

…with no type recorded8
Years with a record 21 calendar years (1993–2020)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
27 - Convention (Subpart B), Net Ton
39 - Regulatory (Subpart C or D), Gross Ton
91 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE8441MMSI 367405530 · expired · compulsorily equipped · granted 21 April 2009, cancelled 22 June 2019 · licensed under a name not among this hull’s recorded names (not shown)
WCY5999MMSI not assigned · expired · compulsorily equipped · granted 29 July 1998, cancelled 4 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

15 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7111886
8 July 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7000896
2 November 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6573517
9 October 2018 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6553405
10 May 2018 Administrative Inspection · Excursion Permit · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6411512
1 February 2018 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6347991
17 October 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6285003
22 August 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5960703
17 July 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5187095
27 August 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4133749
21 July 2011 Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4089700
8 February 2011 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3938803
18 January 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3934184
5 January 2011 Type not recorded
No type recorded · Station Hobucken · USCG East District (CGD-E) · Activity 3921625
3 October 2008 Internal Structural Exam · COI Inspection · Hull Examination · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3339382
15 June 2007 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2962420
10 November 2005 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2571728
21 October 2004 Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2251939
8 September 2003 Deficiency Check · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1900935
13 August 2002 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1661294
14 May 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1629305
24 August 2001 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 212087
24 August 2001 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1425194
4 January 2001 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 825399
27 October 2000 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1055008
25 August 1999 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1395251
31 December 1998 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 807600
1 December 1998 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 806536
9 September 1998 Re-Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1433380
7 April 1998 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 789170
6 August 1997 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1453400
14 August 1996 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1438474
20 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086548
26 July 1995 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1182198
26 April 1995 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1172838
20 October 1994 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 690224
22 July 1994 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 867946
23 May 1994 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 859415
7 March 1994 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 854540
16 February 1994 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 852922
24 January 1994 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 851639
16 September 1993 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1146061
23 April 1993 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 827854
5 April 1993 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1448426
14 March 1993 Plan Review "T" Boat · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1461508

Deficiency record · 62

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 December 2018 Resolved
Vessels hull has extensive corrosion.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2018
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 October 2018 Resolved
Vessels upper deck stowage box was damaged. Renew/repair upper deck life jacket stowage box and remark properly.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2018
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 October 2018 Resolved
MDE lube oil pressure gauge is inoperative. Trouble shoot, renew/replace/repair back to operational as designed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 October 2017 Resolved
Expired (31 Aug 2017) 3 trips with passengers after expiration date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2017
Resolution: Provided e-mail copy of valid COD.
Documentation › Certificates/Documents › FCC SSL
Issued 17 October 2017 Resolved
Provide FFC operators permit 47CFR80.159
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2017
Resolution: Provided e-mail copy of FCC Operators Permit for owner
Lifesaving › Hand Flares › Not on Board
Issued 17 October 2017 Resolved
Missing 2 hand red flares
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2017
Resolution: Owner provided receipt for new flares
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 October 2017 Resolved
Remove 3 type II child PFDs and replace with type I child PFDs
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 27 November 2017
Resolution: Owner provided receipt for life jackets
Construction/Loadline › Hull › Weld
Issued 17 October 2017 Resolved
4" crack on frame 1 stbd outboard side
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 1 December 2017
Resolution: Owner has welder weld crack and install unapproved bracket with bolts to reinforce frames. issue will be addressed at drydock in Feb. 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 October 2017 Resolved
Ring buoy life line needs to be replaced at pilot house and stern
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Ring buoy life lines replaced with new
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 October 2017 Resolved
Ring buoy life line needs to be installed around the body
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 27 November 2017
Resolution: Attached life line properly
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 October 2017 Resolved
Expired Meds
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Replaced expired meds.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 October 2017 Resolved
Replace all Fire Ext. brackets with approved brackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 29 November 2017
Resolution: Owner provided photos and receipt of mounting brackets.
Fire Fighting › Fire Pumps › Arrangement
Issued 22 August 2016 Resolved
Repair engine driven fire/bilge pump misalignment.
Due 22 September 2016
Resolved 17 October 2017
Resolution: Observed fire pump with SAT results.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 August 2015 Resolved
Provide 3 child PFDs prior to vessel operation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2015
Resolved 8 September 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 August 2015 Resolved
Repair fwd void bilge visual and audible alarm system
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 8 September 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 11 August 2015 Resolved
Replace raw water intake hoses IWO port & stbd MDEs and replace hose clamps (double clamp where practicable)
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 14 September 2015
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 August 2015 Resolved
Provide lanyard for fwd void hatch
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 8 September 2015
Construction/Loadline › Structures › Superstructure
Issued 19 October 2011 Resolved
Make permanent repairs to window IWO sink on Port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2011
Resolved 25 October 2011
Resolution: Item previously cleared via phone call.
Personnel › Training › Familiarization Training
Issued 7 May 2009 Resolved
Provide training for all crew members on operation of vessel systems.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 21 May 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 October 2008 Resolved
Provide proper railing courses or covers for vessel railing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 21 May 2009
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 1 October 2008 Resolved
Repair/Replace fathometer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 21 May 2009
Resolution: Fathometer removed from vessel, is not required equipment.
Engineering › Bilge Water Management System › Not Operational
Issued 1 October 2008 Resolved
Repair/replace bilge alarm for #3 void space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 21 May 2009
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 1 October 2008 Resolved
Properly mount VHF radios on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 21 May 2009
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 1 October 2008 Resolved
Repair/replace rudder angle indicator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 21 May 2009
Resolution: Equipment removed from vessel, not required equipment.
Electrical › Lighting (service) › Outlet Box
Issued 1 October 2008 Resolved
Repair/Replace exterior electrical boxes with NEMA 3r covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 21 May 2009
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 1 October 2008 Resolved
Provide Alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 28 May 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 November 2005 Resolved
Portable fire extinguishers not serviced
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2005
Resolved 7 May 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 November 2005 Resolved
Fixed firefighting system not serviced
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2005
Resolved 10 November 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 21 October 2004 Resolved
Hatch cover missing retaining strap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 24 November 2004
Resolution: Observed chain in place on fwd hatch cover
Fire Fighting › Fire Main › Valves
Issued 21 October 2004 Resolved
Replace fractured valve body on fwd firestation
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 November 2004
Resolved 24 November 2004
Resolution: Observed new valve on station and SAT operation of firemain system.
Engineering › Electric Propulsion System › Battery
Issued 21 October 2004 Resolved
Clean up battery stowage in bowthruster space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 24 November 2004
Resolution: Observed clean battery rack in bowthuster space
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 21 October 2004 Resolved
Clean Bilges/remove flammables
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 24 November 2004
Resolution: Observed clean bilges
Engineering › Fuel Oil Service System
Issued 8 September 2003 Resolved
Replace fuel oil hose from Raycor filter to both main engines. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 9 October 2003
Resolved 19 September 2003
Engineering › Bilge Water Management System
Issued 13 August 2002 Resolved
Prove proper operation of installed bilge suction system prior to the carriage of passengers. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2002
Resolved 14 August 2002
Resolution: Operator was able to obtain suction from all void spaces.
Electrical
Issued 27 October 2000 Resolved
PROVIDE GROUND FAULT PROTECTION FOR ELECTRICAL OUTLETS IN THE GALLEY AREA.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Construction/Loadline
Issued 27 October 2000 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS FOR APPROPRIATE SPACES AS REQUIRED BY 46 CFR 182.530.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Lifesaving
Issued 25 August 1999 Resolved
PROVIDE 6 USCG APPROVED DISTRESS SIGNALS IAW 46 CFR 180.68(b)
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Lifesaving
Issued 9 September 1998 Resolved
V/W, MAKE PROPER REPAIRS TO FORWARD RAILINGS, PORT AND STBD AS DISCUSSED.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
VOID #4, BAY #5, AT FIT-UP SEAM IN BOTTOM LONGS #4,5,6,7 V/W FRACTURES TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
VOID #4, WELD FIT-UP HOLES IN TOP MOST CORNERS (PORT AND STBD) OF FORWARD W/T BULKHEAD.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
MAKE PROPER REPAIRS TO AREAS AS NOTED ON ATTACHED WORKLIST.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 9 September 1998 Resolved
PROVIDE 60 FOOT DARK SYNTHETIC OR UV RESISTANT FLOTATION LINE FOR RING BOUY.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 9 September 1998 Resolved
PROVIDE RETRO REFLECTIVE TAPE FOR RING BOUY AS DISCUSSED.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Engineering
Issued 9 September 1998 Resolved
MAKE PROPER REPAIRS TO PORT AND STBD MDE THROTTLE LINKAGES.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 9 September 1998 Resolved
PROVIDE AND PROPERLY POST LIFE JACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
V/W STBD MOORING CLEAT, EVEN WITH AFT END OF DECK HOUSE.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
THIS CG-835 ISSUED IN ERROR, ADMINISTRATIVELY CLEARED.
Condition: Unknown
Due 8 December 1998
Resolved 14 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
SEE ATTACHED DRAW/DIAGRAM (PAGE 3 OF CG-835) FOR LOCATION AND TYPE OF REPAIR TO OUTER HULL AREAS NOTED DURING BOTTOM WALK PORTION OF DRYDOCK EXAMCONDUCTED 09SEP98. VESSEL IS NOT TO OPERATE UNTIL ALL ITEMS OF CG-835'S #9,10,11,12 ARE COMPLETED TO THE SATISFACTION OF THE ATTENDING MI.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Documentation
Issued 9 September 1998 Resolved
PROVIDE PROOF OF 1998 PARTICIPATION/VALID CONTRACT IN A DRUG CONSORTIUM.
Condition: Unknown
Due 8 December 1998
Resolved 11 September 1998
Lifesaving
Issued 9 September 1998 Resolved
PROVIDE WATERTIGHT, BRIGHTLY COLORED CONTAINER FOR FLARES, MARKED "DISTRESSSIGNALS", IN AT LEAST .5" LETTERS.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Engineering
Issued 6 August 1997 Resolved
HOSE BETWEEN SEA CHEST AND GENERATOR WAS NOT DOUBLE CLAMPED.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Fire Fighting
Issued 6 August 1997 Resolved
NO INSTRUCTIONS FOR BILGE/FIRE PUMP MANIFOLD CHANGE-OVER.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Construction/Loadline
Issued 6 August 1997 Resolved
Hailing port not properly marked on the stern of the vessel.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Documentation
Issued 26 April 1995 Resolved
COMPLY WITH NVIC 1-91, SENIOR DECKHAND TRAINING AND DESIGNATION.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Fire Fighting
Issued 26 April 1995 Resolved
DUE TO THE INABILITY OF THE CREW TO SAFELY HANDLE THE EXISTING SUICIDE NOZZLES, REPLACE THEM WITH COAST GUARD APPROVED NOZZLES.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Documentation
Issued 26 April 1995 Resolved
OBTAIN CURRENT COPY OF 46 CFR, PART 166-199, SUB. T.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Fire Fighting
Issued 7 March 1994 Resolved
FIRE HOSES NOT MARKED WITH THE VESSEL'S NAME. PROPERLY MARK HOSES NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Construction/Loadline
Issued 7 March 1994 Resolved
BILGE SUCTION MANIFOLD VALVES NOT LABELED AS TO SOURCE AND SERVICE. PROPERLY LABEL VALVES NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Lifesaving
Issued 7 March 1994 Resolved
DISTRESS SIGNALS NOT IN A PORTABLE, WATERTIGHT CONTAINER STOWED IN THE WHEELHOUSE. STORE SIGNALS PROPERLY NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Documentation
Issued 14 March 1993 Resolved
PROVIDE STABILITY LETTER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 14 March 1993
Resolved 14 March 1993
Documentation
Issued 14 March 1993 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 14 March 1993
Resolved 14 March 1993
Lifesaving
Issued 14 March 1993 Resolved
PRIOR TO CARRYING PASSENGERS IN NEW OPERATING AREA, CONDUCT REQUIRED CREW DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 March 1993
Resolved 14 March 1993

Casualty record · 1

27 August 2011Routine · role: Involved in a Marine Casualty · activity 4133749
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record