← All vessels
ENFORCER
Freight Ship · Bulk Carrier class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named ENFORCER
ENFORCER is a 1992 freight ship. The Coast Guard has recorded 26 inspections since 1992, most recently in February 2008, along with 5 deficiencies and 2 operational controls.
Records from 1992 to 2008. Most recent: operational control imposed, 20 February 2008.
- Built
- 1992
- Last inspected
- 20 February 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9046265 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C4BF2
382114
Flag
CYPRUS
—
Maury page id
psix-382114
Inspections, by type
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it15884 - Regulatory (Subpart C or D), Gross Ton
8992 - Regulatory (Subpart C or D), Net Ton
26388 - Dead Weight, Ton
32206 - Displacement, Ton
8992 - Regulatory (Subpart C or D), Net Ton
26388 - Dead Weight, Ton
32206 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
20 February 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3150149
20 February 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3150209
18 January 2006
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2569224
12 January 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2565893
9 January 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2563719
31 July 2005
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2445972
24 June 2004
MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2109482
24 June 2004
NPV Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2109496
19 February 2003
Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1746234
18 February 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1746170
18 December 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1483152
30 October 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294814
29 May 2001
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 290587
8 May 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 289612
7 August 2000
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 281235
29 February 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 275052
27 September 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 433128
17 May 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 428693
21 September 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 420545
29 May 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416531
4 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 407438
23 March 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 389290
8 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 386636
28 February 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 375416
4 November 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 362841
5 November 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 354343
Deficiency record · 5
Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 February 2008
Resolved
Vessel's class "A" Boundary doors leading into the steering gear room and numerous others in the engine room have internal parts missing and are not self closing. Vessel is to submit a class report attesting the full operational test of the doors.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 20 February 2008
Resolved
Vessels aft bilge well as approx. 1.2m3 of dirty oil. vessel is to submit a receipt of discharge to the U.S. Coast Guard
Fire Fighting
Issued 27 September 1999
Resolved
Provide new foam producing liquid in engine room portable applicator. Liquid expired July 99. Provide prior to next US port. SOLAS 74 amd II-2/7
Fire Fighting
Issued 27 September 1999
Resolved
Repair fire doors between engine room and steering room so that they close and latch properly prior to next US port. SOLAS 74 amd II-2/47
Fire Fighting
Issued 27 September 1999
Resolved
Clean sprinkler heads in paint looker water spray system prior to next US port. SOLAS 74 amd I/11
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.