Records from 1992 to 2002. Most recent: inspection, 1 May 2002.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 9 December 2001
No resolution recorded
To the satisfaction of class, address all exterior IMO signs (lifejacket lockers, etc) to ensure proper location and reflection of stowed safety equipment. Provide class report NLT 09DEC01 or next U.S. port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 December 2001 — due date passed with no resolution recorded
Navigation
Issued 9 December 2001
No resolution recorded
To the satisfaction of class, install audible alarms for steering failure on the navigation bridge IAW SOLAS II-1 Reg 51.1.3 prior to next U.S. port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 December 2001 — due date passed with no resolution recorded
Lifesaving
Issued 9 December 2001
No resolution recorded
To the satisfaction of class, address every lifejacket to ensure presence of whistle and non-expired light prior to next U.S. port or 30 days. Provide class report cognizant OCMI.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 January 2002 — due date passed with no resolution recorded
Lifesaving
Issued 9 December 2001
No resolution recorded
To the satisfaction of class, ensure all lifeboats are fitted with retro-relective tape on the hull.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 January 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 9 December 2001
No resolution recorded
To the satisfaction of class, properly insulate overhead above steering pump with to A-15 prior to next U.S. port or 09JAN02.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 January 2002 — due date passed with no resolution recorded
Documentation
Issued 9 December 2001
No resolution recorded
To the satisfaction of class, address issuance and endorsement date inconsistancies on the company's document of compliance prior to 09JAN02.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 January 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 11 November 1992
Resolved
Remove wood cabinet in aft stair tower on "B" deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Remove combustables in store room on "A" deck under aft pool and from bos'nstores.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992
Resolved
Provide specification sheet for insulation around steering gear hydraulic tank.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Install exit signs in passage ways in crew areas.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Install exit signs showing exit on both sides at cabin 326 to stair and at cabin 126 to stair.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Electrical
Issued 11 November 1992
Resolved
Place emergency lights fixture markings on emergency lights as designated during test.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
Make the fire zone numbering of the ventilation shut downs consistant with the fire zone numbering for the smoke detection system.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992
Resolved
Remove wood sheathing around mast in stair tower on "A" deck frame 90.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992
Resolved
Reinstall watertight coamings leading into piano bar on main deck port and starboard.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Ensure all emergiency exit signs are labeled from both directions of escape.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Make general alarm operable for a secondary location. SOLAS 74 Chapter IIIReg. 50.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Remove all combustible materials stored in the forward A/C room on "B" deck.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Add exit signs to the doors from the engine room.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Accommodation/Occupational Safety
Issued 11 November 1992
Resolved
Make both the double doors at the top of the stair exiting the steering gear room operable with action by a single door handle.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Install exit signs from the pantry on "A" deck.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Lifesaving
Issued 11 November 1992
Resolved
Remove house hold fan in paint locker.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
Spanner wrench at fire station # 16 not in reach.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992
Resolved
Remove wood cabinents in bowthruster space or insulate as type 13_x001C_ storeroom.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
Prove proper installation and operation of sprinkler pump. Pump is to be electrical wired in accordance with SOLAS 74/#2 Reg 12.7.1.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
Replace all fog applicators located in interior spaces with four foot applicators.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Accommodation/Occupational Safety
Issued 11 November 1992
Resolved
Remove mechanical holdback from galley door.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992
Resolved
Properly re-wire proximity switch for water tight door number eight.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
Amend fire plan to show store room in port corridor on "B" deck.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
Amend fire plan to show sprinkler and drencher shut off valves that are contained in a locker. Remove stores from this space.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992
Resolved
Install missing insulation on bulkhead in way of sprinkler/drencher locker,A-15 required.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Fire Fighting
Issued 11 November 1992
Resolved
At fire station #16, relocate fire extinguisher to an area that is nom readily accessible also relocate fire station labeling to make it mor visible, See item SJ03.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Engineering
Issued 11 November 1992
Resolved
Post "NO DISCHARGE" placards for oil pollution prevention.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992