← All vessels
NAVEGANTE
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southwest District (CGD-SW) · Other hulls named NAVEGANTE
NAVEGANTE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2000, most recently in June 2008, along with 24 deficiencies and 1 casualty investigation in 2004.
Records from 2000 to 2008. Most recent: inspection, 26 June 2008.
- Built
- 2000
- Last inspected
- 26 June 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2004
Identity
1094087
WCZ8934
3822
Flag
UNITED STATES
338775000 (licence lapsed)
Maury page id
psix-3822
Inspections, by type
…with no type recorded6
Years with a record
8 calendar years (2000–2008)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Net Ton
95 - Regulatory (Subpart C or D), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCZ8934MMSI 338775000 · expired · compulsorily equipped · granted 20 June 2000, cancelled 21 August 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 20
26 June 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3248790
12 October 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2799096
10 September 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2750163
9 August 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2741680
9 August 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2741717
20 July 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2710889
18 July 2005
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2431242
15 June 2005
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2390619
16 December 2004
Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2257020
15 December 2004
Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2254896
21 October 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2263629
26 July 2004
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2135657
25 May 2004
Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2080517
11 June 2003
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1815003
2 June 2003
Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1807773
12 July 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1629905
30 May 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1622234
14 September 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 772480
10 August 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1436615
12 June 2000
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 819117
Deficiency record · 24
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 September 2006
Resolved
Provide copy of service report and proper operation
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 September 2006
Resolved
Provide service report for life rafts
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 September 2006
Resolved
Conduct drills
Lifesaving › Lifefloat › Serviceable
Issued 11 September 2006
Resolved
Repair life float (15 man ) topside
Lifesaving › Lifebuoys › Serviceable
Issued 11 September 2006
Resolved
Apply retro-tape to life buoy
Electrical › Lighting (service) › Lighting Fixture
Issued 11 September 2006
Resolved
Repair light fixture starboard side bridge
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 September 2006
Resolved
Provide current crew list and proof of company enrollment
Engineering › Bilge Water Management System › Not Operational
Issued 11 September 2006
Resolved
Prove that bilge system is operational.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 September 2006
Resolved
Update CG Light List
Navigation › Piloting/Steering › Marine Charts
Issued 11 September 2006
Resolved
Update Local Charts
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 September 2006
Resolved
Update US Coast Pilot
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 September 2006
Resolved
Update Tide/Tidal Current tables
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 September 2006
Resolved
Install rails on 2nd deck boat area
Documentation › Certificates/Documents › FCC SSL
Issued 15 June 2005
Resolved
Renew Communications Act Certificate
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 June 2005
Resolved
Mount fire extinguisher in upper deck galley
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 15 June 2005
Resolved
Install indicators on WTD's to indicate open/close at control station iaw 46 CFR 179/330(b).
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 May 2004
Resolved
Provide plans for completed alteration and installation of a galley space in the port main deck berthing space. Plans shall include electrical wiring diagram and load test. Plumbing arrangement and weight calculations for installation. LEGACY COMPONENT DESC: Alteration Plans and approval
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 25 May 2004
Resolved
Provide heat shield around new stove installation.
Operations/Management › Equipment Service/Testing
Issued 2 June 2003
Resolved
Replace antenna on EPIRB, to the satisfaction of the CG Inspector. IAW 46 CFR 185.728(b). This deficiency limits the route of this vessel to no more than one(1) nautical mile from shore until this deficiency has been cleared. LEGACY COMPONENT DESC: EPIRB
Documentation
Issued 10 August 2001
Resolved
Provide proof of pre-employment drug testing for crew members.
Documentation
Issued 10 August 2001
Resolved
Lable bridge for 14 passengers only as per stability letter.
Construction/Loadline
Issued 10 August 2001
Resolved
Repair bilge alarm system.
Documentation
Issued 10 August 2001
Resolved
Provide updated FCC safety certificate.
Lifesaving
Issued 10 August 2001
Resolved
provide plan for installation of new system to recover man overboard.
Casualty record · 1
21 October 2004Routine · role: Involved in a Marine Investigation (non-casualty) · activity 2263629
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.