EMERALD

EMERALD is a 1993 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2025, along with 9 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 20 May 2025.

Built
1993
Last inspected
20 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 May 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ9110
382224
Flag
UNITED STATES
Maury page id
psix-382224

Documentation record

Registered dimensions (L × B × D)57.7 ft × 13.2 ft × 7.5 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUB SEA SYSTEMS, INC. · RANCHO CORDOVA, CA, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

20 May 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8047111
27 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7883690
13 March 2024 Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845399
1 June 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7670984
27 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7436147
3 March 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7381497
12 August 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7019450
14 November 2019 Hull Examination · In-Service Inspection · Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6856275
17 July 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732757
20 June 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414197
29 March 2018 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6360690
16 May 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129064
15 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879059
9 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5808400

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Multiple electrical receptacles found with missing faceplate in the following locations: battery room on STBD side and AC systems room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery charger missing face plate with unprotected conductors for A/C power system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2024 Resolved
Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jackets to float free. All stowage locations for PFDs had latching system that could allow for securing the PFDs unintentionally thus restricting their access.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2024 Resolved
Wiring sizes for lighting and power shall be in accordance with Table 183.05-45(a); minimum size is 14AWG. Multiple circuits found with 16-18AWG, wire utilized to supply the conductors to bilge pump and PA system in Port Electrical panel compartment. Remove all undersized wires supplying power with a minimum 14AWG conductor that is UL listed or labels as boat cable. OLD T: 46 CFR 183.05-45(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2024 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Fill pipes for all 4 fuel tanks had no bonding for joining the 2 metallic sections (fill to tank). OLD T: 46 CFR 182.20-30(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, provided that: A positive shutoff valve is installed at the hull penetration. Multiple submersible bilge pumps installed on vessel that do not have a positive shutoff valve or unable to visually inspect valve because access to overboard was not available. Provide positive shutoff valve at all hull overboard penetrations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113 (incorporated by reference; see 46 CFR 175.600). Multiple submersible bilge pumps installed on vessel that are 500GPH to 2000GPH; provide documentation that all installed bilge pumps are UL 1113 listed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 1 August 2024
Resolution: Vessel provided proof of UL Approved Bilge Pump
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Due to wastage of life jacket material, as well as that of some retroreflective tape, the vessel was unable to provide the 40 adult life jackets as listed as the maximum passenger allowance on the Certificate of Inspection. The passenger count is reduced accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 29 April 2022
Resolution: Vessel owner provided photos attesting to new retroreflective tape on life jackets.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 March 2016 Resolved
Vertical height between horizontal rail courses exceeds 12 inches, on all six access/embarkation zones. Provide additional rail courses so no vertical height is greater than 12 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 22 April 2016
Resolution: Inspected proper installation of railing...all satisfactory