EMERALD

EMERALD is a 1993 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 1992, most recently in May 2025, along with 47 deficiencies.

Records from 1992 to 2025. Most recent: inspection, 20 May 2025.

Built
1993
Last inspected
20 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9110
382224
Flag
UNITED STATES
367302480
Maury page id
psix-382224

Inspections, by type

…with no type recorded12
Years with a record 28 calendar years (1992–2025)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.7 ft × 13.2 ft × 7.5 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUB SEA SYSTEMS, INC. · RANCHO CORDOVA, CA, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9110MMSI 367302480 · active · compulsorily equipped · granted 10 February 2018, expires 10 February 2028
WDD8765MMSI 367302480 · expired · voluntarily equipped · granted 12 July 2007, cancelled 16 September 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 76

20 May 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8047111
27 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7883690
13 March 2024 Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845399
1 June 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7670984
27 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7436147
3 March 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7381497
12 August 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7019450
14 November 2019 Hull Examination · In-Service Inspection · Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6856275
17 July 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732757
20 June 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414197
29 March 2018 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6360690
16 May 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129064
15 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879059
9 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5808400
18 June 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4864762
12 March 2014 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4798082
16 May 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4257938
13 January 2012 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4273907
11 June 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3202755
10 March 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3139191
6 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2953252
22 May 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2925467
8 June 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2639042
16 March 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2593986
23 June 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2392900
17 February 2005 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2294564
26 July 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2142683
2 February 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1998878
16 June 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1816573
21 March 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1762254
14 May 2002 Construction Oversight · Plan Review "T" Boat · Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1616631
1 October 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1073672
16 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1370419
4 April 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1415727
19 July 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1401284
12 May 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395454
5 May 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1049859
24 February 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408465
27 May 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424775
3 March 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384029
3 June 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368771
21 May 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424596
10 February 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 774981
16 April 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364073
3 February 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407820
8 July 1996 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380606
30 May 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390265
30 January 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371263
9 November 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 875337
2 August 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367462
24 May 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357183
29 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1159671
20 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 830826
22 November 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865495
25 October 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172981
15 October 1994 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1180593
14 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 109886
17 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 13092
17 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 44403
17 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164717
28 October 1993 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143558
22 October 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156981
19 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844131
19 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1179057
13 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868678
13 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155082
2 July 1993 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1157293
1 June 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868425
1 June 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153185
6 May 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868550
6 May 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1135460
30 April 1993 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148465
9 March 1993 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 836556
12 February 1993 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1141410
17 December 1992 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132234
13 November 1992 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1133345

Deficiency record · 47

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Multiple electrical receptacles found with missing faceplate in the following locations: battery room on STBD side and AC systems room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery charger missing face plate with unprotected conductors for A/C power system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2024 Resolved
Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jackets to float free. All stowage locations for PFDs had latching system that could allow for securing the PFDs unintentionally thus restricting their access.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2024 Resolved
Wiring sizes for lighting and power shall be in accordance with Table 183.05-45(a); minimum size is 14AWG. Multiple circuits found with 16-18AWG, wire utilized to supply the conductors to bilge pump and PA system in Port Electrical panel compartment. Remove all undersized wires supplying power with a minimum 14AWG conductor that is UL listed or labels as boat cable. OLD T: 46 CFR 183.05-45(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2024 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Fill pipes for all 4 fuel tanks had no bonding for joining the 2 metallic sections (fill to tank). OLD T: 46 CFR 182.20-30(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, provided that: A positive shutoff valve is installed at the hull penetration. Multiple submersible bilge pumps installed on vessel that do not have a positive shutoff valve or unable to visually inspect valve because access to overboard was not available. Provide positive shutoff valve at all hull overboard penetrations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113 (incorporated by reference; see 46 CFR 175.600). Multiple submersible bilge pumps installed on vessel that are 500GPH to 2000GPH; provide documentation that all installed bilge pumps are UL 1113 listed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 1 August 2024
Resolution: Vessel provided proof of UL Approved Bilge Pump
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Due to wastage of life jacket material, as well as that of some retroreflective tape, the vessel was unable to provide the 40 adult life jackets as listed as the maximum passenger allowance on the Certificate of Inspection. The passenger count is reduced accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 29 April 2022
Resolution: Vessel owner provided photos attesting to new retroreflective tape on life jackets.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 March 2016 Resolved
Vertical height between horizontal rail courses exceeds 12 inches, on all six access/embarkation zones. Provide additional rail courses so no vertical height is greater than 12 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 22 April 2016
Resolution: Inspected proper installation of railing...all satisfactory
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 June 2014 Resolved
Replace 08 Adult size lifejackets. (Resolved on the spot)
Action required: 705 - Other - as specified
Resolved 18 June 2014
Resolution: Vessel owner replaced 08 lifejackets on the spot.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 16 May 2012 Resolved
Provide bowls for fuel filters of steel construction.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 11 June 2012
Resolution: Vessel replaced bowls for fuel filters.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 May 2012 Resolved
Replace ring buoy lines (lifeline = 60 feet), (waterlight lanyard = 3 feet).
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 11 June 2012
Resolution: Vessel replaced both lines.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2007 Resolved
Provide metal supports for electrical wiring throughout the engine room no more than 24 inches apart.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 5 June 2007
Resolution: Owner/operator provided pictures of the metals supports throughout the engine room that he had installed in the areas of the engine room that I had required metal supports for.
Construction/Loadline
Issued 12 May 2000 Resolved
Provide a means to visually indicate when each bilge pump is operating at the bilge control station.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000 Resolved
Install hose clamps on engine room bilge hose connections.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000 Resolved
Secure all submersible electric bilge pumps in place.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 12 May 2000 Resolved
Provide proper (approved) bracket for the engine room fire extinguisher.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 27 May 1999 Resolved
Provide nozzle suitable for fire fighting on portable fire pump.
Condition: Unknown
Due 27 June 1999
Resolved 7 July 1999
Engineering
Issued 27 May 1999 Resolved
Install a guard over rotating machinery on the starboard main engine.
Condition: Unknown
Due 27 June 1999
Resolved 7 July 1999
Lifesaving
Issued 21 May 1998 Resolved
Vessel needs a Coast Guard Approved First Aid Kit or a kit with equivalent items in accordance with 46 CFR table 160.054-4(b) NLT 29MAY98. Kit that was on board did not have required items.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Navigation
Issued 30 May 1996 Resolved
Provide magnetic compass deviation table.
Condition: Unknown
Due 30 May 1996
Resolved 30 May 1996
Electrical
Issued 30 May 1996 Resolved
Remove all unused wiring and make satisfactory repair to existing cable andwiring.
Condition: Unknown
Due 30 May 1996
Resolved 30 May 1996
Lifesaving
Issued 2 August 1995 Resolved
Mark all lifesaving equipment with new name of vessel: EMERALD.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Navigation
Issued 2 August 1995 Resolved
Mark vessel on both sides of bow and stern with new vessel name: EMERALD.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Electrical
Issued 2 August 1995 Resolved
Properly mount electrical junction block, in engine room on port side.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Electrical
Issued 2 August 1995 Resolved
Hard wire ventilation fan in passenger view deck aft.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Electrical
Issued 2 August 1995 Resolved
Make operational all emergency lighting on ladder leading to/from passengerviewing deck.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Accommodation/Occupational Safety
Issued 24 May 1995 Resolved
Emergency exits not properly labeled fwd and aft.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Navigation
Issued 24 May 1995 Resolved
Corrected charts and applicable publications missing.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Unknown
Issued 29 March 1995 Resolved
POST THE EMERGENCY PROCEDURES ON BOARD.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Electrical
Issued 29 March 1995 Resolved
COMPLETE THE INSTALLATION AND PROVE THE PROPER OPERATION OF THE UNDERWATER LIGHTS PER APPROVED PLAN.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Documentation
Issued 29 March 1995 Resolved
PROVIDE AND POST STABILITY LETTER ON BOARD.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Navigation
Issued 29 March 1995 Resolved
PROVIDE CURRENT NAVIGATION CHARTS OF THE AREA OF OPERATION.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Lifesaving
Issued 29 March 1995 Resolved
PROVIDE ADDITIONAL SEVEN(7) ADULT-SIZE LIFE PRESERVERS OR TOTAL OF 49 ADULTSIZE LIFE PRESERVERS ON BOARD. VESSEL IS LIMITED TO 42 TOTAL PERSONS (CREW AND PASSENGERS) ON BOARD UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
PROVIDE 50 AMP BEAKER FROM THE SERVICE GENERATOR TO THE MAIN AC POWER LINE.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Fire Fighting
Issued 29 March 1995 Resolved
PROVIDE AND PROPERLY INSTALL ONE(1) B-II PORTABLE FIRE EXTINGUISHER FOR THEENGINE ROOM SPACE.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Unknown
Issued 29 March 1995 Resolved
PROVIDE WASTE MANAGEMENT PLAN ON BOARD.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Documentation
Issued 25 October 1994 Resolved
PROVIDE EMERGENCY CHECKOFF LIST WHICH INCORPORATES ELEMENTS OF 46 CFR 185.25-5.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Navigation
Issued 25 October 1994 Resolved
PROVIDE CURRENT DEVIATION CARD FOR MAGNETIC COMPASS.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Documentation
Issued 25 October 1994 Resolved
PROVIDE DRUG TESTING PROGRAM.
Condition: Unknown
Due 28 October 1994
Resolved 1 November 1994
Engineering
Issued 15 October 1994 Resolved
REMOVE, CAP OFF, AND PROPERLY BY PASS UNUSED RACOR FUEL FILTERS IN ENGINE ROOM.
Condition: Unknown
Due 15 October 1994
Resolved 15 October 1994
Electrical
Issued 15 October 1994 Resolved
TRACE OUT ENTIRE ELECTRICAL SYSTEM TO DETERMINE AMOUNT OF LOAD ON EACH BATTERY, PRIMARILY ELECTRICAL LOAD FOR MATHERS MICRO [name withheld] IS TO LIMIT ELECTRICAL LOAD FOR VESSEL WHILE UNDERWAY WITH PASSENGERS. SUBMIT PLANS OR REPAIR PROPOSALS.
Condition: Unknown
Due 15 October 1994
Resolved 15 October 1994
Electrical
Issued 15 October 1994 Resolved
SECURE GENERATOR CONTROL BOX TO THE TOP OF GEN SET.
Condition: Unknown
Due 15 October 1994
Resolved 15 October 1994
Engineering
Issued 17 March 1994 Resolved
REPAIR THROTTLE CABLE AND COMPLETE/SUBMIT A CG FORM 2692 (REPORT OF MARINE CASUALTY). UPON COMPLETION, CONTACT USCG GROUP MONTEREY TO ARRANGE COAST GUARD EXAMINATION OF REPAIR.
Condition: Unknown
Due 17 April 1994
Resolved 28 March 1994
Electrical
Issued 1 June 1993 Resolved
PROVIDE DOCUMENTATION THAT THE TRAILER CORD IN DC VOLT ELECTRICAL SYSTEM MEETS THE REQUIREMENTS OF DWG SS3531 DTD 25OCT91.
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Navigation
Issued 1 June 1993 Resolved
REPLACE HYDRAULIC HOSE TO REQUIRED PIPE TO MEET THE REQUIREMENTS OF DWG 3537 DTD 26OCT91.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Documentation
Issued 6 May 1993 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, COMPLETE 37 ITEM WORK LIST TO THE SATISFACTION OF THE COGINZANT O.C.M.I. ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 10 September 1993
Resolved 10 September 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.