Records from 1992 to 2011. Most recent: operational control imposed, 10 December 2011.
Inspection history · 24
9 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4205426
8 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4204530
6 December 2011
COE-Offshore · ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4202669
6 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4203216
6 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4203225
6 January 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3918758
24 February 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3685639
18 January 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3663119
12 May 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3473254
2 February 2009
Deficiency Check · ISPS I Exam · PII Safety Exam · Ballast Water Examination · ISM Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3402036
2 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3404022
12 April 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3182672
17 March 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3166283
22 January 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3134083
21 October 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1933187
29 September 2003
Ballast Water Examination · Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1920038
20 November 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 295203
6 February 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286801
24 January 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 273975
23 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391509
9 November 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 34846
18 May 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 378596
25 January 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 461877
16 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 491739
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 December 2011
No resolution recorded
1530-Radar-All ships of 3000 Gt and upwards shall have a 3Ghz radar. Ships 3Ghz radar is inoperable. Solas ('09 cons. ed.) Ch. 5, Reg. 19.2.7.1 (17c)
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Structural - Main Vertical Zones › General
Issued 2 February 2009
Resolved
Three fire doors on main vertical fire zones are not operating properly. Fire doors must be repaired and working properly to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: Resolved.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 February 2009
Resolved
Excessive oil in the vicinity of the main engine and ships service generators causing a fire and pollution hazard. Bilge must be cleaned and free from oil and sludge to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 2 February 2009
Resolved
The incinerator is not operational. Incinerator must be repaired to the satisfaction of the certificate issuing authority.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Lifesaving › Rescue Boat › Propulsion Engine
Issued 2 February 2009
Resolved
Port lifeboat engine not operational. Lifeboat must be repaired and working properly to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 2 February 2009
Resolved
Winch brakes on both port and starboard lifeboat davit launching system inoperative. Gravity brakes must be repaired and working properly to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2009
Resolved
Vegetable reefer condenser is wired to a standard light switch, creating an electrocution hazard. Must be repaired to the satisfaction of the certificate issuing authority prior to departure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 2 February 2009
Resolved
There was no evidence that non-conformities had been submitted in accordance with the safety management system on board the vessel. Vessel must complete an internal ISM audit prior to departure. This is a detainable deficiency.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 January 2008
Resolved
Vessel X band radar is not working and did not work during inbound transit. Vessel is to submit tech repairs prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2008
Resolved 24 January 2008
Resolution: Received report from technician attesting to the proper operation of the radar. All tests and operations show good performance and normal functions.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 22 January 2008
Resolved
Vessel Master failed to notify COTP of inoperable X band radar prior to arrival to Sector Del Bay.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 January 2008
Resolved 23 January 2008
Resolution: PSCO issued NOV.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 22 January 2008
Resolved
Vessel does not have a USCG approval certificate for their Marine Sanitation Device type II. Vessel needs to provide USCG with approval certificate prior to discharging sewage in U.S. waters.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 January 2008
Resolution: Vessel provided USCG with Coast Guard approval certificate.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 29 September 2003
Resolved
LOADLINE CERTIFICATE INDICATES TROPICAL, FRESH, WINTER, ETC. MARKINGS WHICH ARE NOT DISPLAYED ON SHIPS HULL
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 September 2003
Resolved
FIRE CONTROL PLAN DOES NOT HAVE FLAG STATE APPROVAL.
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Engineering › Steering Gear System › Motor
Issued 29 September 2003
Resolved
PORT STEERING MOTOR HAS WORN BEARING NOISE WHEN OPERATING.
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Engineering › Fuel Oil Service System › Flange
Issued 29 September 2003
Resolved
HIGH PRESSURE FUEL LINES FOR PROPULSION DIESEL DO NOT HAVE OUTER JACKET SECURED PROPERLY.
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Lifesaving
Issued 6 February 2001
Resolved
EACH LIFEBOAT DID NOT HAVE A TOTAL OF 3 CAN OPENERS, IN VIOLATION OF SOLAS 74/78 III/41-8.2.3.
Condition: Unknown
Due 20 November 2001
Resolved 20 November 2001
Lifesaving
Issued 6 February 2001
Resolved
SEASICKNESS PILLS MISSING FROM LIFEBOATS, IN VIOLATION OF SOLAS 74/78 III/41-8.2.1.
Condition: Unknown
Due 20 November 2001
Resolved 20 November 2001