ARGENTINA STAR is a 1992 freight ship. The Coast Guard has recorded 24 inspections since 1992, most recently in December 2011, along with 17 deficiencies — 1 with no resolution recorded — and 6 operational controls.

Records from 1992 to 2011. Most recent: operational control imposed, 10 December 2011.

Built
1992
Last inspected
9 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8814304 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
382288
Flag
BAHAMAS, THE
—
Maury page id
psix-382288

Inspections, by type

…with no type recorded17
Years with a record 11 calendar years (1992–2011)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10629 - Regulatory (Subpart C or D), Gross Ton
10629 - Convention (Subpart B), Gross Ton
4253 - Regulatory (Subpart C or D), Net Ton
10588 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

9 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4205426
8 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4204530
6 December 2011 COE-Offshore · ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4202669
6 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4203216
6 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4203225
6 January 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3918758
24 February 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3685639
18 January 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3663119
12 May 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3473254
2 February 2009 Deficiency Check · ISPS I Exam · PII Safety Exam · Ballast Water Examination · ISM Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3402036
2 February 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3404022
12 April 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3182672
17 March 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3166283
22 January 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3134083
21 October 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1933187
29 September 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1920038
20 November 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 295203
6 February 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286801
24 January 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 273975
23 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391509
9 November 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 34846
18 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 378596
25 January 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 461877
16 November 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 491739

Deficiency record · 17

Navigation › Collision/Grounding Avoidance › Radar
Issued 6 December 2011 No resolution recorded
1530-Radar-All ships of 3000 Gt and upwards shall have a 3Ghz radar. Ships 3Ghz radar is inoperable. Solas ('09 cons. ed.) Ch. 5, Reg. 19.2.7.1 (17c)
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Structural - Main Vertical Zones › General
Issued 2 February 2009 Resolved
Three fire doors on main vertical fire zones are not operating properly. Fire doors must be repaired and working properly to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: Resolved.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 February 2009 Resolved
Excessive oil in the vicinity of the main engine and ships service generators causing a fire and pollution hazard. Bilge must be cleaned and free from oil and sludge to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 2 February 2009 Resolved
The incinerator is not operational. Incinerator must be repaired to the satisfaction of the certificate issuing authority.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Lifesaving › Rescue Boat › Propulsion Engine
Issued 2 February 2009 Resolved
Port lifeboat engine not operational. Lifeboat must be repaired and working properly to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 2 February 2009 Resolved
Winch brakes on both port and starboard lifeboat davit launching system inoperative. Gravity brakes must be repaired and working properly to the satisfaction of the Certificate issuing authority prior to departure. This is a detainable deficiency
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2009 Resolved
Vegetable reefer condenser is wired to a standard light switch, creating an electrocution hazard. Must be repaired to the satisfaction of the certificate issuing authority prior to departure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 2 February 2009 Resolved
There was no evidence that non-conformities had been submitted in accordance with the safety management system on board the vessel. Vessel must complete an internal ISM audit prior to departure. This is a detainable deficiency.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: resolved
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 January 2008 Resolved
Vessel X band radar is not working and did not work during inbound transit. Vessel is to submit tech repairs prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2008
Resolved 24 January 2008
Resolution: Received report from technician attesting to the proper operation of the radar. All tests and operations show good performance and normal functions.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 22 January 2008 Resolved
Vessel Master failed to notify COTP of inoperable X band radar prior to arrival to Sector Del Bay.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 January 2008
Resolved 23 January 2008
Resolution: PSCO issued NOV.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 22 January 2008 Resolved
Vessel does not have a USCG approval certificate for their Marine Sanitation Device type II. Vessel needs to provide USCG with approval certificate prior to discharging sewage in U.S. waters.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 January 2008
Resolution: Vessel provided USCG with Coast Guard approval certificate.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 29 September 2003 Resolved
LOADLINE CERTIFICATE INDICATES TROPICAL, FRESH, WINTER, ETC. MARKINGS WHICH ARE NOT DISPLAYED ON SHIPS HULL
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 September 2003 Resolved
FIRE CONTROL PLAN DOES NOT HAVE FLAG STATE APPROVAL.
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Engineering › Steering Gear System › Motor
Issued 29 September 2003 Resolved
PORT STEERING MOTOR HAS WORN BEARING NOISE WHEN OPERATING.
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Engineering › Fuel Oil Service System › Flange
Issued 29 September 2003 Resolved
HIGH PRESSURE FUEL LINES FOR PROPULSION DIESEL DO NOT HAVE OUTER JACKET SECURED PROPERLY.
Due 29 October 2003
Resolved 22 January 2008
Resolution: Corrected.
Lifesaving
Issued 6 February 2001 Resolved
EACH LIFEBOAT DID NOT HAVE A TOTAL OF 3 CAN OPENERS, IN VIOLATION OF SOLAS 74/78 III/41-8.2.3.
Condition: Unknown
Due 20 November 2001
Resolved 20 November 2001
Lifesaving
Issued 6 February 2001 Resolved
SEASICKNESS PILLS MISSING FROM LIFEBOATS, IN VIOLATION OF SOLAS 74/78 III/41-8.2.1.
Condition: Unknown
Due 20 November 2001
Resolved 20 November 2001

Ownership record