EAGLE 1

EAGLE 1 is a 1992 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1993, most recently in May 2025, along with 62 deficiencies and 1 operational control.

Records from 1993 to 2025. Most recent: inspection, 7 May 2025.

Built
1992
Last inspected
7 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

382419
Flag
UNITED STATES
—
Maury page id
psix-382419

Inspections, by type

…with no type recorded3
Years with a record 30 calendar years (1993–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)30.0 ft × 11.8 ft × 3.3 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFISH RITE BOATS · CENTRAL POINT, OR, UNITED STATES · built 1992
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portKLAMATH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Net Ton
7 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

7 May 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 8124123
15 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7901533
11 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7686907
2 June 2022 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7466807
9 June 2021 Drydock Exam · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7221582
22 September 2020 Administrative Inspection
Administrative · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7063060
6 May 2019 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6678254
9 October 2018 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6557853
3 May 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6449524
7 June 2017 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6168855
11 August 2016 Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5966653
17 May 2016 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5915500
29 July 2015 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5200380
16 May 2012 Simplified Stability Test · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4313326
9 August 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 4072151
15 December 2009 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3720793
10 July 2008 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3264084
26 March 2008 Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3169091
17 May 2007 COI Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2905090
11 October 2006 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2797986
12 October 2005 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2513070
7 October 2004 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2216195
24 July 2003 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1859720
12 June 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1831395
15 July 2002 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1788007
10 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075381
31 July 2001 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1389488
29 July 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 22794
13 July 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1445829
17 June 1999 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387110
5 July 1998 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1399155
31 March 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388633
7 July 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1428796
22 April 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1353935
4 May 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883838
4 May 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403984
19 July 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1411032
26 May 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170743
15 October 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 214392
17 September 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1147885
11 May 1993 Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153273
22 April 1993 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1395921

Deficiency record · 62

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2025 Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. MARINE INSPECTOR OBSERVED... engine start switches were not interlocked to blowers. Operator to repair circuit so that both engine start switches are properly interlocked to blowers, and to provide proper warning sign at operating station, to the satisfaction of the attending marine inspector. 46 CFR 182.460(e)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2025
Resolution: Operator installed exhaust blower/engine starting interlock. Witnessed satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2025 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. MARINE INSPECTOR OBSERVED... required 10-B:C extinguisher did not have up to date annual servicing. Operator to have extinguisher replaced or serviced to the satisfaction of the marine inspector. 46 CFR 176.810(b)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Operator sent photo of updated maintenance tag for 10-B:C fire extinguisher.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2025 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, required by the vessel's Certificate of Inspection. MARINE INSPECTOR OBSERVED... operator did not have proper documentation at time of inspection describing procedures for random drug testing. Operator to provide documentation of procedures for random drug testing to the satisfaction of the marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2025
Resolution: Operator provided copy of company random drug testing policy.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 May 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MARINE INSPECTOR OBSERVED... vessel did not have emergency instructions posted. Operator to provide documentation of emergency instructions, and may be kept with drill logs, to the satisfaction of the marine inspector. 46 CFR 185.510
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2025
Resolution: Marine inspector provided copy of 46 CFR 185.512 to operator, which satisfies the requirements of 46 CFR 185.510.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2024 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: A space containing machinery powered by gasoline; A space containing a fuel tank for gasoline. Vessel currently has incomplete Fireboy installation. Operator to complete proper installation to the satisfaction of the Marine Inspector, prior to the carriage of passengers. 46 CFR 181.400(a)(4)(5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2024
Resolution: Operator submitted photos showing proper install of proper installation of extinguishing system in accordance with 46 CFR 181.400(b)(5).
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 September 2020 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in §176.500(b)(1) and your Certificate of Inspection must be endorsed. The vessel failed to schedule or complete the required annual inspection. The vessel must complete a re-inspection for COI prior to operating.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2020
Resolved 25 June 2021
Resolution: Cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 June 2017 Resolved
COI is expired. Renew COI prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2017
Resolved 12 June 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2017 Resolved
First Aid Kit incomplete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 29 June 2017
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 June 2017 Resolved
Provide new lifejacket placard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 29 June 2017
Documentation › Markings/Placards › Oil Discharge Placard
Issued 7 June 2017 Resolved
Provide new oil discharge placard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 29 June 2017
Lifesaving › Visual Distress Signals (General) › Storage
Issued 29 July 2015 Resolved
Flares must be stowed in a portable watertight container carried at operating station. Acquire required container and have ready for inspection
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 7 August 2015
Resolution: A portable watertight container was purchased and placed into service.
Documentation › Markings/Placards › Official Number (US)
Issued 29 July 2015 Resolved
Official number must be permanently affixed to the interior structural member. Install and provide proof to the USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 17 May 2016
Resolution: Vessel owner installed a permanently mounted official number plate in the engine space.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 29 July 2015 Resolved
Fuel vapor sensor inoperable. Repair fuel vapor sensor and have ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2015
Resolution: Operator discovered that during the inspection the power was not switched on when it was tested. USCG Marine inspector verified that it was operational.
Engineering › Fuel Oil Service System › Tank
Issued 21 May 2012 Resolved
Install a corrosion resistant flame screen on gasoline vent piping.
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 22 May 2012
Resolution: Installed the proper flame screen on the fuel vent piping.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 21 May 2012 Resolved
Prove proper operation of the install vapor detection system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2012
Resolution: The vessel installed a new system and proved the proper operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 May 2012 Resolved
Show proof of servicing on the installed CO2 fire fighting system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2012
Resolution: Proper conducted annual servicing of the system and provided the proper proof.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2012 Resolved
Provide aspirin for first aid kit.
Action required: 705 - Other - as specified
Due 2 June 2012
Resolved 22 May 2012
Resolution: Added the required amount of aspirin to the first aid kit.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 August 2011 Resolved
Provide current Tide Tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 10 August 2011
Resolution: Operator provided current Tide Tables.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 August 2011 Resolved
Provide proof of annual fire extinguisher servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 10 August 2011
Resolution: Operator provided proof of annual fire extinguisher servicing.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 9 August 2011 Resolved
Provide flame screen to fuel vent of corrosion resistant wire of at least 30x30 mesh.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2011
Resolved 10 August 2011
Resolution: Operator provided flame screen of corrosion resistant wire of 30x30 mesh.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 August 2011 Resolved
Provide proof of fire extinguisher bracket mounted underneath control panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 10 August 2011
Resolution: Operator installed fire extinguisher bracket mount underneath the control panel.
Engineering › Gasoline Engine (propulsion) › Alternator (4 cycle)
Issued 9 August 2011 Resolved
Provide proof of installation and operation of starboard alternator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 10 August 2011
Resolution: Operator provided proof of installation and operation of starboard alternator.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 September 2008 Resolved
The vessel's aluminum fuel tank is bolted to the aluminum hull and it sits on the frames. Provide non-abrasive and non-absorbent material between fuel tank and hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 15 December 2009
Resolution: Material is now in place.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 17 September 2008 Resolved
Vessels ventilation from deck into engine space has no means to secure the airflow during a fire and in support of the fixed firefighting system. Provide closure devises on all vents to the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 15 December 2009
Resolution: Closure devices are in place.
Documentation › Markings/Placards › Warning Signs
Issued 17 September 2008 Resolved
Provide a red warning sign identifying the need to operate blowers in the blowers in the engine space prior to starting engines to ensure on complete air exchange
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 15 December 2009
Resolution: Warning sign is in place.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 September 2008 Resolved
Provide lables for switches on insturment /fuse panel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 15 December 2009
Resolution: Switches are labeled.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 17 September 2008 Resolved
As vessel's Fixed Firefighting System (Halon) is automatically activated (heat sensor), the system is not designed to automatically shut down the engine and the operator expects to continue using the engine to provide propulsion and steering (i/o jet river boat). Operator is to ensure engines shut down prior to the activation of the Halon fire supression system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 15 December 2009
Resolution: Due to the narrowness of the river and plans to manuever the vessel to shore in case of vessel fire, the safety of the crew and pax is best served by letting the operator manuever the jet boat to a safe location rather than have the engines shut down.
Engineering › Bilge Water Management System › Interface Detector
Issued 17 May 2007 Resolved
Ensure proper operation of bilge high-level alarm system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2007
Resolution: New switch and buzzer/light installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 7 October 2004 Resolved
Prior to carrying passengers, replace portable fiire extinguisher due to pressure gauge broken.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 12 October 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 October 2004 Resolved
Provide copy of Certificate of Documentation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 12 October 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 October 2004 Resolved
Provide copy of drug test program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 12 October 2005
Lifesaving › Lifebuoys › Serviceable
Issued 7 October 2004 Resolved
Prior to carrying passengers, replace life ring due to grab line rotton and ring body wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 12 October 2005
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 12 June 2003 Resolved
Connect remote operating pull station to halon bottle, or as an alternative re-install portable CO2 bottle outside of engine space IAW 46 CFR 181.20-5(b) (1), (2), (3). LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 12 June 2003
Resolved 12 June 2003
Fire Fighting › Miscellaneous Items
Issued 15 July 2002 Resolved
Clean oil from bilges.
Action required: 705 - Other - as specified
Resolved 17 July 2002
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 July 2002 Resolved
Provide proof of drug testing program for all employees.
Action required: 705 - Other - as specified
Resolved 17 July 2002
Engineering
Issued 31 July 2001 Resolved
PROVIDE GUARDS OVER BELTS AND PULLY WHEELS IN MACHINERY SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 August 2001
Resolved 19 October 2001
Documentation
Issued 31 July 2001 Resolved
PROVIDE PROOF OF SUBMISSION OF ANNUAL DRUG TEST REPORTS.
Condition: Unknown
Due 10 August 2001
Resolved 19 October 2001
Documentation
Issued 31 July 2001 Resolved
PROVIDE RECORDS/LOGS OR OTHER EVIDENCE OF CREWMEMBER TRAINING.
Condition: Unknown
Due 10 August 2001
Resolved 19 October 2001
Lifesaving
Issued 31 July 2001 Resolved
PROVIDE LOGS, RECORDS OR OTHER EVIDENCE WHICH SHOWS MONTHLY CHECKS OF LIFE SAVING AND FIRE FIGHTING EQUIPMENT HAS BEEN PERFORMED.
Condition: Unknown
Due 10 August 2001
Resolved 19 October 2001
Fire Fighting
Issued 31 July 2001 Resolved
CONDUCT ANNUAL SERVICING OF PORTABLE FIRE EXTINGUISHERS AND FIXED SYSTEM INMACHINERY SPACES.
Condition: Unknown
Due 10 August 2001
Resolved 19 October 2001
Documentation
Issued 31 July 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 August 2001
Resolved 19 October 2001
Construction/Loadline
Issued 17 June 1999 Resolved
COMPLETE INSTALLATION OF HIGH WATER BILGE ALARMS (BOTH VISUAL AND AUDIO AT STEERING STATION).
Condition: Unknown
Due 15 July 1999
Resolved 25 June 2001
Fire Fighting
Issued 17 June 1999 Resolved
COMPLETE INSTALLATION OF VAPOR DECTECTION AND ALARM SYSTEM (BOTH VISUAL ANDAUDIO AT STEERING STATION).
Condition: Unknown
Due 15 July 1999
Resolved 25 June 2001
Lifesaving
Issued 17 June 1999 Resolved
POST LIFE JACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 15 July 1999
Resolved 25 June 2001
Documentation
Issued 17 June 1999 Resolved
PROVIDE PROOF OF ALL EMPLOYEES IN THE RANDOM DRUG TESTING PROGRAM
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Lifesaving
Issued 17 June 1999 Resolved
REPLACE THREE ORANGE SMOKE FLARES.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Lifesaving
Issued 17 June 1999 Resolved
MASTER (TIM WING) TO COMPLETE FIRST AID AND CPR TRNG (REFRESHER COURSE)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1999
Resolved 25 June 2001
Lifesaving
Issued 5 July 1998 Resolved
PROVIDE/PLACE ADDITIONAL RETROREFLECTIVE TAPE ON BOTH SIDES OF RING BOUY FOR A TOTAL OF 4 BANDS 2" WIDE EACH SIDE.
Condition: Unknown
Due 20 August 1998
Resolved 22 July 1999
Lifesaving
Issued 5 July 1998 Resolved
IDENTIFY/MARK LIFE JACKET STOWAGE AREAS WITH NUMBER AND TYPE (ADULT/CHILD) JACKETS STOWED IN EACH COMPARTMENT
Condition: Unknown
Due 20 August 1998
Resolved 22 July 1999
Fire Fighting
Issued 5 July 1998 Resolved
COMPLETE ANNUAL INSPECTIONS OF PORTABLE FIRE EXTINGUISHERS AND FIXED SYSTEMIN ENGINE COMPARTMENT.
Condition: Unknown
Due 20 August 1998
Resolved 22 July 1999
Engineering
Issued 5 July 1998 Resolved
REPAIR/REPLACE MECHANICAL EXHAUST BLOWER ON STBD SIDE OF ENGINE COMPARTMENT.
Condition: Unknown
Due 20 August 1998
Resolved 22 July 1999
Lifesaving
Issued 22 April 1996 Resolved
Provide two Adult size life preserverse on board. The vessel may not carry more than 36 persons on board untill there is a total of 38 Adult life preservers on board.
Condition: Unknown
Due 22 May 1996
Resolved 4 June 1996
Lifesaving
Issued 22 April 1996 Resolved
Provide three new orange smoke flares on board.
Condition: Unknown
Due 22 May 1996
Resolved 4 June 1996
Lifesaving
Issued 4 May 1995 Resolved
Provide 3 additional adult life preservers the vessel is limited to 35 persons until this requirment is met.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 19 July 1994 Resolved
Have portable and fix fire extinguishers serviced.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Engineering
Issued 11 May 1993 Resolved
REPLACE THE FUEL TANK VENT LINE WITH ONE THAT MEETS 46CFR182.15-35.
Condition: Unknown
Due 17 August 1993
Resolved 17 August 1993
Documentation
Issued 11 May 1993 Resolved
DEVELOPE AND PROVIDE FOR REVIEW TO USCG MSO SAN FRANCISCO THE COMPANYS DRUGTESTING PROGRAM.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Documentation
Issued 11 May 1993 Resolved
DEVELOPE AND PROVIDE FOR REVIEW TO USCG MSO SAN FRANCISCO BAY AN OPERATIONSMANUAL.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Documentation
Issued 22 April 1993 Resolved
PROVIDE PROOF OF DOCUMENTATION. (COASTWISE SERVICE)
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Lifesaving
Issued 22 April 1993 Resolved
PROVIDE PFD'S (38 ADULT AND 4 CHILD).
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Lifesaving
Issued 22 April 1993 Resolved
PROVIDE NAME OF VESSEL ON ALL PFD'S AND RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Engineering
Issued 22 April 1993 Resolved
PROVIDE COAST GUARD APPROVED HOSES ON FUEL TANK FILL AND VENTS.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.