MAURY USCG vessel records Sign in
← All vessels

CHENNAI VALARCHI

CHENNAI VALARCHI is a 1982 freight ship. The Coast Guard has recorded 4 inspections since 1992, most recently in June 2000, along with 11 deficiencies — 7 with no resolution recorded —.

Records from 1992 to 2000. Most recent: inspection, 28 June 2000.

Built
1982
Last inspected
28 June 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8128066 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
382446
Flag
INDIA
—
Maury page id
psix-382446

Inspections, by type

…with no type recorded4
…past their stated due date7
Years with a record 3 calendar years (1992–2000)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23991 - Regulatory (Subpart C or D), Gross Ton
13042 - Regulatory (Subpart C or D), Net Ton
38019 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

28 June 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279283
19 February 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 425672
19 January 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 424574
9 November 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 354541

Deficiency record · 11

Lifesaving
Issued 28 June 2000 No resolution recorded
REPAIR OR REMOVE TOWER ON AFT, STARBOARD SIDE OF BRIDGE DECK, WHICH IS MISSING SUPPORT._x001C_ ILLC 66 ANNEX I
Condition: Unknown
Due 28 July 2000 — due date passed with no resolution recorded
Engineering
Issued 28 June 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL SEA SUCTION PIPE TO OILY WATER SEPARATOR._x001C_ MARPOL 73/78 ANNEX I/16
Condition: Unknown
Due 28 July 2000 — due date passed with no resolution recorded
Engineering
Issued 28 June 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL DRAIN ON SECOND STAGE OF OILY WATER SEPARATOR WHICH IS REPAIRED WITH A CEMENT PATCH._x001C_ MARPOL 73/78 ANNEX I/16
Condition: Unknown
Due 28 September 2000 — due date passed with no resolution recorded
Engineering
Issued 28 June 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL STEAM INLET PIPES TO MAIN ENGINE FUEL OIL HEATERS._x001C_ SOLAS 74 1/II
Condition: Unknown
Due 28 July 2000 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 28 June 2000 No resolution recorded
FUMIGATE GALLEY, MESS DECK AND FOOD STORE AREA TO REMOVE BUGS._x001C_ ILO 147
Condition: Unknown
Due 28 July 2000 — due date passed with no resolution recorded
Engineering
Issued 28 June 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL MAIN ENGINE COOLING WATER INLET PIPE._x001C_ SOLAS 74 I/II
Condition: Unknown
Due 28 July 2000 — due date passed with no resolution recorded
Fire Fighting
Issued 28 June 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL SHAFT PACKING FOR MAIN FIRE PUMP._x001C_ SOLAS 74 (AMEND) II-2/21
Condition: Unknown
Due 11 July 2000 — due date passed with no resolution recorded
Documentation
Issued 19 January 1999 Resolved
Provide a valid cargo ship safety radio certificate prior to departure fromthis port. SOLAS 74 amd I/11 & 12
Condition: Unknown
Due 20 January 1999
Resolved 21 January 1999
Fire Fighting
Issued 19 January 1999 Resolved
Repair all fire doors in main stairwell so that they close and latch properly. Correct prior to next US Port after sailing foreign. SOLAS 74 II-2/51 amd I/11.
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Navigation
Issued 9 November 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 November 1992
Resolved 18 November 1992
Navigation
Issued 9 November 1992 Resolved
VESSEL FAILED TO HAVE U.S. COAST GUARD LIGHT LIST ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1992
Resolved 18 November 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.