DOLPHIN RACER

DOLPHIN RACER is a 1993 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1993, most recently in May 2026, along with 64 deficiencies and 3 casualty investigations between 2006 and 2019.

Records from 1993 to 2026. Most recent: inspection, 4 May 2026.

Built
1993
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4109
382616
Flag
UNITED STATES
367383760
Maury page id
psix-382616

Inspections, by type

…with no type recorded9
Years with a record 31 calendar years (1993–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 19.0 ft × 10.0 ft
Registered tonnagegross 82 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · ELMORE, AL, UNITED STATES · built 1993
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST. PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Net Ton
82 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4109MMSI 367383760 · active · compulsorily equipped · granted 24 February 2017, expires 24 February 2027
WCY8483MMSI 367383760 · cancelled · voluntarily equipped · granted 7 November 2008, cancelled 22 February 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

4 May 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8334130
19 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8111248
29 January 2025 Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8060495
6 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7897614
11 January 2024 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7850537
11 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7671801
24 January 2023 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7612468
7 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7470982
24 February 2022 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7394337
20 August 2021 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7291491
26 May 2021 Annual Inspection · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7194162
12 January 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7111977
22 July 2020 Simplified Stability Test · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7048446
3 March 2020 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6918933
1 March 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6919936
17 December 2019 Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6876853
17 December 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6881779
23 September 2019 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6818618
10 May 2019 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6681251
29 January 2019 In-Service Inspection · Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6610164
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512852
30 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6388559
9 January 2017 Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6082303
4 April 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5845427
17 March 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4816238
20 July 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4384923
28 February 2012 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4253059
13 February 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4243640
18 February 2011 Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3947818
12 January 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3925568
8 January 2009 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3394077
2 June 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3235527
12 March 2007 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2884082
17 January 2007 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2842519
28 June 2006 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2680376
30 March 2006 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2613132
30 March 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2618223
23 January 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2571592
28 March 2005 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2319668
12 January 2005 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2273763
19 November 2004 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2250634
30 January 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1964179
8 July 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1887400
12 June 2003 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1859819
10 June 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1812989
4 April 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1778914
3 April 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1778453
15 March 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1493900
2 October 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1074565
19 June 2001 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1406954
28 March 2001 Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1370087
19 May 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 822553
23 November 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467639
20 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 730990
13 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 79720
1 March 1999 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1463457
25 February 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414941
26 March 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452270
13 February 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1356095
29 March 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367714
29 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1357224
19 July 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1191990
6 July 1995 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390082
7 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401999
17 February 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380163
7 September 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863957
6 May 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171214
22 August 1993 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 223392
26 February 1993 COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150605

Deficiency record · 64

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 10 life jackets were found with deteriorated floatation foam and were condemned. Replacement jackets bought, labeled, and stowed before the inspection was completed. 46 CFR 176.808
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 May 2025
Resolved 19 May 2025
Resolution: New life jackets were bought, labeled, and stowed before the inspection was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2025 Resolved
Thewater light, required for night time operation, shall be stowed and attached the the ring life buoy nearest the opeating station. The float light was not operating as it should. Repair or replace the float light. A new float light was onboard prior to the completion of the inspection. 46 CFR 180.30-10
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 19 May 2025
Resolved 19 May 2025
Resolution: A new float light was onboard prior to the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel 13 adult life jacket in non-serviceable condition. Max persons on board reduced to 118. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 6 May 2024
Resolved 16 May 2024
Resolution: 13 approved type adult life jackets purchased and placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 May 2024 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the a light to indicate discharge. Lights on pre-engineered fixed gas fire extinguishing system alarm display are inoperable. 46 CFR 181.420(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 13 May 2024
Resolution: Alarm display replaced SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 May 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Cracks located on the starboard bow rail and loose mounting hardware located on multiple rail mounts. 46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 30 May 2023
Resolution: Received photos of repaired welds on bow rail.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 11 May 2023 Resolved
A vessel must comply with the applicable requirements for any radio...set forth in 47 CFR part 80. Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1)Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. 2) Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license. Vessel representative did not radio operator permit present. 46 CFR 184.502 46 CFR 80.159(e)(1)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 1 June 2023
Resolution: Received photo of radio operator permit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had 6 unserviceable life jackets. 46 CFR 180.71
Action required: 10 - Deficiency Rectified
Due 11 May 2023
Resolved 11 May 2023
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The port side bulkhead longitudinal stringer located in the engine room is cracked. Operator will make repairs like and in kind. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 March 2022
Resolution: The fractured longitudinal stringer was cropped to a 1:12 ratio and the fiberglass was renewed as per the original layup to this vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. There is no overcurrent protection between the alternator and the distribution panel. 46 CFR 183.380(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 March 2022
Resolution: Vessel installed overcurrent protection
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. There is no overcurrent protection between the battery and the distribution panel. 46 CFR 183.380(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 March 2022
Resolution: Vessel installed overcurrent protection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. There is no overcurrent protection between shore power and the battery chargers. AC conductors must be protected by a UL 489 circuit breaker. 46 CFR 183.380(a), 46 CFR 183.380(m)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 March 2022
Resolution: Vessel installed overcurrent protection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part. A new battery charger and shore power connection conductors were installed on the vessel without submitting plans. Vessel must submit plans for approval to MSC. 46 CFR 183.115(c) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 March 2022
Resolution: Vessel submitted electrical plans to MSC.
02 - Structural Conditions › N/A - No Subsystem › Damage control plan
Issued 26 May 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the OCMI. Identified fractured starboard rudder post mount base plate. The mount was found fractured entirely from fwd to stern and permitting water to enter the space when steering maneuvers were performed. Provide repair plan to OCMI and make satisfactory repairs. 46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2021
Resolution: The operator dry docked the vessel and replaced the starboard rudder post internal mount in kind. Repairs were verified and sea trials were conducted in the presence of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2021 Resolved
Seating accommodations for passengers are required to be provided only when the max number of passengers permitted has been determined by using fixed seating criteria. Identified (18) passenger seats fractured and unusable. Passenger count reduced by (18). Renew seating as original or provide proposal for seating arrangement. 46 CFR 177.30-1
Action required: 705 - Other - as specified
Due 7 June 2022
Resolved 7 June 2022
Resolution: The operator submitted a proposal to change all passenger seating to aluminum bench seating. The proposal was approved by the Sector St. [name withheld] and installed in June 2022.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2021 Resolved
An adult life jacket must be provided for each person carried onboard the vessel. (01) adult life jacket was found in poor condition. Passenger count reduced by (01) adult. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 25 July 2021
Resolved 3 June 2021
Resolution: 01 CG approved adult life jacket was purchased by the owner, labeled in accordance with the regulations, and placed into service on the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 May 2021 Resolved
Rails or equivalent shall be installed near the periphery of all weather decks accessible to pax & crew. Stbd fwd railing found fractured. Renew as original. 46 CFR 177.35-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 3 June 2021
Resolution: The operator hired a third party welder to crop and renew the railing. MI visually inspected weld repair to the railing; all sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 May 2021 Resolved
On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in 182.530. Vessels greater than 26 feet shall have a visual and audible alarm at the operating station to indicate high water levels in spaces identified in 182.530. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 3 June 2021
Resolution: The bilge high level alarm was replaced by the operator in kind. The operator tested all high water alarms in the presence of the MI; the audible and visual alarms are now in satisfactory working condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 March 2020 Resolved
Provide operational test of the main propulsion system to the satisfaction of the marine inspector. 46CFR182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2020
Resolution: Cleared during the Annual inspection under activity #7048446.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 December 2019 Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. The vessel's steering gear was reported as inoperable. Repair to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2019
Resolved 19 December 2019
Resolution: O/O replaced copper hydraulic piping. Conducted operational test; SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 September 2019 Resolved
Delamination in way of stern. 46CFR176.20-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2019
Resolution: Owner completed repairs on delaminated section of vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 May 2019 Resolved
On wooden vessels, bonding together of the enclosures and frames of major electrical equipment to a common ground shall be effected. Inspector found bonding wires disconnected. Connect all bonding wires as required by cited regulation. 46 CFR 183.05-50(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 28 May 2019
Resolution: Bonding wires properly connected.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 May 2019 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Inspector found lighting fixture in engine room without protective cover. Provide protective cover for fixture. 46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 31 May 2019
Resolution: Replaced all light fixtures with LED lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2019 Resolved
Unless a splice is made by an insulated pressure wire connector listed by Underwriters' Laboratories, Inc., it shall be thoroughly soldered, taped first with rubber and then with friction tape, or the soldered joint shall be otherwise protected as to provide an insulation the same as that of the conductors joined. Inspector found dead ended wires in aft steering and tank compartments. Remove wires or properly secure as per cited regulation. 46 CFR 183.05-50(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 28 May 2019
Resolution: Dead-ended wires properly capped.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting: Invalid MSI, no static draft information, and incomplete dimension information (AIS Antenna Position “X” equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 19 November 2018
Resolution: Vessel corrected AIS Deficiencies
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 30 April 2018 Resolved
Place name of vessel and hailing port on stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2018
Resolution: Verified operator has placed name of vessel and hailing port on stern.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 April 2018 Resolved
Prove proper operation of mast head light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2018
Resolution: Operator corrected wire run to operate mast head light.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 March 2017 Resolved
On lifebouy found buoyant lifeline way to long. Make buoyant lifeline 60 feet as required.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: The buoyant lifeline was corrected on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2017 Resolved
Found line for self-igniting light way too long. Make line 3-6 feet as required.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: Item was corrected on the spot.
Engineering › Bilge Water Management System › Manifold
Issued 1 March 2017 Resolved
Fixed bilge water management system manifold in engine room was not labled. Lable all valves to location on vessel.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: Item was corrected on the spot.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 February 2017 Resolved
Replace aft stbd cutlass bearing.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Aft stbd cutlass bearing was replaced as required.
Construction/Loadline › Hull › Bottom Plating
Issued 17 February 2017 Resolved
Repair delamination and if greater than superficial Marine Inspector to re-exam.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: The delamination was only superficial.
Accommodation/Occupational Safety › Ventilation › General
Issued 17 February 2017 Resolved
Remove bad plywood (with angle hair) around upper vent over port and stbd engines to good plywood and seal engrains.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: All angle hair was removed and plywood was sealed to help prevent moisture entry.
Construction/Loadline › Structures › Deck Plating
Issued 17 February 2017 Resolved
Remove bad plywood forward of stbd engine access cover to good plywood and insert a new piece, as original, and seal to include engrains.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: Area was renewed as original and as required.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 14 January 2017 Resolved
Complete credited hull inspection and power trials for engines being overhauled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2017
Resolution: Completed satisfactory engine runs on both MDE's to include steering tests.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 April 2016 Resolved
Replace oil cool lines for reduction gear.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 13 April 2016
Resolution: New oil cool lines installed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 April 2016 Resolved
Replace 03 PFDs, reduced passenger count to 127.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 13 April 2016
Resolution: Replaced 03 PFDs, passenger count restriction removed.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2016 Resolved
Affix grounding straps to motor mount brackets.
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 13 April 2016
Resolution: Grounding straps affixed to motor mount brackets.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 March 2014 Resolved
Provide 13 lifevests. Vessel limited to carrying 118 total persons, 115 passengers. 46 CFR 180.71
Due 24 March 2014
Resolved 20 March 2014
Resolution: Provided 15 new lifejackets.
Engineering › Bilge Water Management System › Pump
Issued 12 March 2007 Resolved
Provide a workable portable hand bilge pump. They have placed a 8 foot pick-up tube to the hand pump instead of putting it at the discharge end of the hand pump. Pump does not take suction unless you prime pump first.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 March 2007
Resolved 19 March 2007
Resolution: Bought a new portable hand bilge pump.
Documentation › Certificates/Documents › FCC SSL
Issued 12 March 2007 Resolved
Provide a copy of [name withheld] Marine Operating Permit. [name withheld] states his card is at home.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 March 2007
Resolved 15 March 2007
Resolution: Rcvd a faxed copy of permit.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 March 2007 Resolved
Provide a safety guard for STBD engine PTO, as discussed. No guard around pulley next to switch to energize the bilge pump.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 March 2007
Resolved 19 March 2007
Resolution: Safety shield in place and switch is mounted away from PTO.
Electrical › Electric Supply System (service) › Cable
Issued 21 June 2006 Resolved
Remove all wire nuts on bilge pump wires and other misc. wiring through out the vessel.
Condition: Placed in Improper Service
Due 5 July 2006
Resolved 7 July 2006
Resolution: ALL NUTS HAVE BEEN REPLACED WITH PROPER CONNECTIONS.
Electrical › Electric Supply System (service) › Cable
Issued 21 June 2006 Resolved
Prove trim tab wires meet 46CFR183.340. They had new trim tabs installed and ran wire that has a label of (353.98 INSUL-8 CORP).
Condition: Placed in Improper Service
Due 5 July 2006
Resolved 7 July 2006
Resolution: O/O PROVIDED DATA FROM MANUFACTURER ATTESTING TO THE PROPER CABLE.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 June 2006 Resolved
Label amount and size of life jacket storage under seats. They placed jackets under seats, but have not labeled size or amount.
Condition: Improper/Lack of Maintenance
Due 5 July 2006
Resolved 7 July 2006
Resolution: ALL SEATS ARE LABELED.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 30 March 2006 Resolved
Prior to the carriage of passengers, repair oil leak(s) on PORT MDE and prove repairs to attending USCG Marine Inspector. See narrative for details.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2006
Resolved 5 April 2006
Resolution: ALL LEAKS HAVE BEEN FIXED AND NEW TURBO-CHARGER HAS BEEN INSTALLED. CONDUCTED A SATISFACTORY U/W TEST.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 March 2006 Resolved
Prior to the carriage of passengers, clean oil from PORT engine room BLKHD, PORT MDE block, and under PORT MDE bilge. See narrative for details.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2006
Resolved 5 April 2006
Resolution: ENGINE ROOM HAS BEEN CLEANED AND ALL OIL HAS BEEN REMOVED.
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 March 2005 Resolved
REPAIR COMPASS LIGHT PRIOR TO OPERATION AT NIGHT.
Due 28 April 2005
Resolved 7 April 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 28 March 2005 Resolved
PROVIDE MANUFACTURER SPECIFICATIONS OF NORMAL OPERATING TEMPERATURE OF TURBOCHARGERS.
Due 28 April 2005
Resolved 7 April 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 January 2004 Resolved
REPAIR STERN AND MASTHEAD LIGHTS PRIOR TO CARRIAGE OF PASSENGERS AT NIGHT.
Due 1 March 2004
Resolved 19 November 2004
Resolution: SAT.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 January 2004 Resolved
WIRE BLOWERS IN ENGINE ROOM INTEGRAL WITH FIXED FIREFIGHTING SHUTDOWN. BLOWERS MUST REMAIN SECURED UNTIL COMPLETED.
Due 1 March 2004
Resolved 19 November 2004
Resolution: DISCONNECTED.
Lifesaving › Hand Flares
Issued 9 June 2003 Resolved
Provide 6 daytime smoke signals prior to carrying passengers for hire. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2003
Resolved 8 July 2003
Resolution: Owner provided 6 daytime smoke signals.
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 June 2003 Resolved
Renew retrotape on 15 child lifejackets as identified. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2003
Resolved 8 July 2003
Resolution: Owner renewed retrotape on 15 child lifejackets.
Navigation › Collision/Grounding Avoidance
Issued 9 June 2003 Resolved
Repair anchor light prior to night operations. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 8 July 2003
Resolution: Owner repaired anchor light.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Replace 2 tabs for under deck transverse, 2nd compartment fwd of aft steering. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 4 April 2003
Resolution: Owner replaced 2 tabs under deck transverse frame.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Replace 2 tabs in fuel tank space port. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 4 April 2003
Resolution: Owner replaced 2 tabs in fuel tank space port.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Replace 2 tabs in fuel tank space stbd. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 4 April 2003
Resolution: Owner replaced 2 tabs in fuel tank space stbd.
Construction/Loadline › Penetrations
Issued 3 April 2003 Resolved
Renew port sea valve. LEGACY COMPONENT DESC: Valve Flange
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 4 April 2003
Resolution: Owner renewed port main engine sea valve.
Electrical
Issued 19 June 2001 Resolved
TERMINATE OR REMOVE DEADEND CABLES IN PORT STORAGE LOCKER IAW 46 CFR 183.340
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 19 June 2001 Resolved
PROVIDE EPIRB REGISTRATION PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 26 June 2001
Resolved 22 June 2001
Navigation
Issued 19 June 2001 Resolved
PROVIDE NAVIGATION PUBLICATIONS, CG LIGHT LIST, COAST PILOT, TIDE TABLES, IAW 46 CFR 184.420
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 19 June 2001 Resolved
RENEW RETRO REFLECTIVE TAPE ON IDENTIFIED LIFEJACKETS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 June 2001
Resolved 2 July 2001
Construction/Loadline
Issued 28 March 2001 Resolved
RE-FIBERGLASS THE ENDS (TABS) OF THE UNDERDECK STRUCTURAL SUPPORTS TO THE HULL FOR BOTH THE LONGITUDINAL AND TRANSVERSE FRAMES TO SUPPORT THE BOX CAPTO HULL ATTACHMENT JOINT.
Condition: Unknown
Due 29 April 2001
Resolved 5 April 2001
Documentation
Issued 19 May 2000 Resolved
46 CFR 15 - ENROLL ALL CREW MEMBERS IN A DOT APPROVED DRUG CONSORTIUM.
Condition: Unknown
Due 19 May 2000
Resolved 7 September 2000
Documentation
Issued 19 May 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 May 2000
Resolved 7 September 2000

Casualty record · 3

30 March 2006Routine · role: Involved in a Marine Casualty · at JOHNS PASS BRIDGE · activity 2618223
19 August 2012Routine · role: Involved in a Marine Casualty · activity 4436949
17 December 2019Routine · role: Involved in a Marine Casualty · activity 6881779
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.